Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 50 A |
Full Load Amps-Resistive | 80 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 200 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 7-1/2 |
HP @ 1 Phase - 120V | 3 hp |
HP @ 1 Phase - 240V | 7 1/2 hp |
Height | 2.17 in |
Width | 2.17 in |
HP @ 3 Phase - 208V | 15 hp |
HP @ 3 Phase - 240V | 15 hp |
HP @ 3 Phase - 575V | 40 hp |
Depth | 4.61 in |
HP @ 3 Phase - 480V | 40 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed |
Series | TeSys Deca |
Includes | Everlink Power Connections |
NEMA Size | Not Applicable |
Rated Voltage | 690V AC, 300V DC |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Rated Breaking Capacity | 900 A @ 440V |
Overvoltage Category | CAT III |
Working Height | Up to 9842.52 ft |
Mounts On | Plate, Rail |
Electrical Durability | 1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V) |
Net Weight | 0.855 kg |
Features | Without Built-In Suppressor Module |
Max. Temperature | 850°C |
Rated Short-Time Withstand Current | 400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Max. Operating Watts | 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e) |
Switching Voltage | 17 V (Signalling Circuit) |
Application | Motor Control, Resistive Load |
Includes Protective Cover | Yes |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit) |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
IP Rating | IP20 |
Watts Loss | 4 to 5W |
Operating Speed | 3600 cycles per hr |
Rated Insulation Volts | 600/690V |
Fuse Amps | 10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit) |
Signalling Circuit Frequency | 25 to 400 Hz |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Fire Rating | UL 94 V1 |
Impedance | 1.5 mOhm |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
Impulse Withstand Voltage | 6 kV |
Non-Overlap Time | 1.5 ms |
Switching Current | 5 mA (Signalling Circuit) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
Mechanical Durability | 6 Mcycles |
Contactor Style | IEC |
Horsepower @ Single Phase - 240V AC | 7 1/2 hp |
Overall Width | 2.17 in |
Full Load Current - Inductive | 50 A |
Minimum Operating Temperature | -40 Degrees F |
Horsepower @ Three Phase - 480V AC | 40 hp |
Overall Height | 4.8 in |
NEMA Enclosure Rating | No Enclosure |
Resistance Properties | Fire Resistant, Insulation Resistant |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 208V AC | 15 hp |
Maximum Operating Temperature | 140 Degrees F |
Maximum Voltage Rating | 690V AC |
Frequency | 50/60 Hz |
Number of Auxillary Contacts | 2 |
Mounting Style | DIN Rail, Plate |
Electrical Operating Durability | 1,100,000, 1,450,000 |
Coil Voltage | 200V AC |
Overall Depth | 4.72 in |
NEMA Enclosure Material | Not Applicable |
Full Load Current - Resistive | 80 A |
Terminal Connection Type | Screw Clamp Terminals |
Includes Auxiliary Contacts | Yes |
Reversing Capability | Non-Reversing |
Horsepower @ Single Phase - 120V AC | 3 hp |
Horsepower @ Three Phase - 240V AC | 15 hp |
Phase | Three |
Horsepower @ Three Phase - 600V AC | 40 hp |
Mechanical Operating Durability | 6,000,000 |
Number of Normally Open Main Contacts | 3 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 200 V AC, 50 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D50AL7
$282.26
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$282.26
You must be logged in to post a review.