Discount -3%

IEC Magnetic Contactor, 3 Poles, 200 V AC, 50 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D50AL7

$282.26

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200V AC, Number of Poles 3, Full Load Current - Inductive 50 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$282.26
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D50AL7
Availability: Ships in 1 days
SKU: GRG1157003 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive50 A
Full Load Amps-Resistive80 A
ActionNon-Reversing
Number of Poles3
Coil Volts200 V AC
ReversingNo
HP @ 1 Phase - 230V7-1/2
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 240V7 1/2 hp
Height2.17 in
Width2.17 in
HP @ 3 Phase - 208V15 hp
HP @ 3 Phase - 240V15 hp
HP @ 3 Phase - 575V40 hp
Depth4.61 in
HP @ 3 Phase - 480V40 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
SeriesTeSys Deca
IncludesEverlink Power Connections
NEMA SizeNot Applicable
Rated Voltage690V AC, 300V DC
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Breaking Capacity900 A @ 440V
Overvoltage CategoryCAT III
Working HeightUp to 9842.52 ft
Mounts OnPlate, Rail
Electrical Durability1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
Net Weight0.855 kg
FeaturesWithout Built-In Suppressor Module
Max. Temperature850°C
Rated Short-Time Withstand Current400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Max. Operating Watts15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
Switching Voltage17 V (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Includes Protective CoverYes
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)
Electrical ConnectionControl Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
IP RatingIP20
Watts Loss4 to 5W
Operating Speed3600 cycles per hr
Rated Insulation Volts600/690V
Fuse Amps10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit)
Signalling Circuit Frequency25 to 400 Hz
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Fire RatingUL 94 V1
Impedance1.5 mOhm
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Impulse Withstand Voltage6 kV
Non-Overlap Time1.5 ms
Switching Current5 mA (Signalling Circuit)
Thermal Amperage10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit)
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Mechanical Durability6 Mcycles
Contactor StyleIEC
Horsepower @ Single Phase - 240V AC7 1/2 hp
Overall Width2.17 in
Full Load Current - Inductive50 A
Minimum Operating Temperature-40 Degrees F
Horsepower @ Three Phase - 480V AC40 hp
Overall Height4.8 in
NEMA Enclosure RatingNo Enclosure
Resistance PropertiesFire Resistant, Insulation Resistant
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 208V AC15 hp
Maximum Operating Temperature140 Degrees F
Maximum Voltage Rating690V AC
Frequency50/60 Hz
Number of Auxillary Contacts2
Mounting StyleDIN Rail, Plate
Electrical Operating Durability1,100,000, 1,450,000
Coil Voltage200V AC
Overall Depth4.72 in
NEMA Enclosure MaterialNot Applicable
Full Load Current - Resistive80 A
Terminal Connection TypeScrew Clamp Terminals
Includes Auxiliary ContactsYes
Reversing CapabilityNon-Reversing
Horsepower @ Single Phase - 120V AC3 hp
Horsepower @ Three Phase - 240V AC15 hp
PhaseThree
Horsepower @ Three Phase - 600V AC40 hp
Mechanical Operating Durability6,000,000
Number of Normally Open Main Contacts3
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#200 V AC
#50 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D50AL7
#SCHNEIDER ELECTRIC
#GRG1157003
#mfr:LC1D50AL7
#part number:LC1D50AL7
#pn:LC1D50AL7
#part code:LC1D50AL7
#item number:LC1D50AL7
#product code:LC1D50AL7
#manufacturer number:LC1D50AL7
#manufacturers part number:LC1D50AL7
#mfn:LC1D50AL7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!