Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 32 A |
Action | Non-Reversing |
Full Load Amps-Resistive | 50 A |
Number of Poles | 3 |
Coil Volts | 208 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 5 |
HP @ 1 Phase - 120V | 2 hp |
Height | 3.36 in |
HP @ 1 Phase - 240V | 5 hp |
HP @ 3 Phase - 208V | 10 hp |
Width | 1.77 in |
Depth | 3.62 in |
HP @ 3 Phase - 575V | 30 hp |
HP @ 3 Phase - 240V | 10 hp |
HP @ 3 Phase - 480V | 20 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Auxiliary Contact Form | 1NO/1NC |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Series | TeSys Deca |
Includes Protective Cover | Yes |
Overvoltage Category | CAT III |
Impedance | 2 mOhm |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Non-Overlap Time | 1.5 ms |
Electrical Connection | Screw Clamp Terminals |
Working Height | Up to 9842.52 ft |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Fuse Amps | 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit) |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit) |
Fire Rating | UL 94 V1 |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit) |
Rated Short-Time Withstand Current | 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Shock Resistance | 8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Application | Motor Control, Resistive Load |
Rated Breaking Capacity | 550 A @ 440V |
Mounts On | Plate, Rail |
Electrical Durability | 1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V) |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Operating Speed | 3600 cycles per hr |
Rated Voltage | 690V AC, 300V DC |
Net Weight | 0.375 kg |
Impulse Withstand Voltage | 6 kV |
Max. Temperature | 850°C |
Mechanical Durability | 15 Mcycles |
Max. Operating Watts | 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Signalling Circuit Frequency | 25 to 400 Hz |
Rated Insulation Volts | 600/690V |
Features | Without Built-In Suppressor Module |
IP Rating | IP20 |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Watts Loss | 2 to 3W |
Switching Current | 5 mA (Signalling Circuit) |
Inrush VA | 70 VA |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit) |
Includes Auxiliary Contacts | Yes |
Full Load Current - Inductive | 32 A |
Horsepower @ Three Phase - 240V AC | 10 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Horsepower @ Single Phase - 240V AC | 5 hp |
Electrical Operating Durability | 1,400,000, 1,650,000 |
Overall Depth | 3.62 in |
Frequency | 50/60 Hz |
Maximum Operating Temperature | 140 Degrees F |
Terminal Connection Type | Screw Clamp Terminals |
Coil Voltage | 208V AC |
Reversing Capability | Non-Reversing |
Full Load Current - Resistive | 50 A |
Mechanical Operating Durability | 15,000,000 |
Contactor Style | IEC |
Number of Auxillary Contacts | 2 |
Horsepower @ Three Phase - 480V AC | 20 hp |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 600V AC | 30 hp |
Overall Width | 1.77 in |
Number of Normally Open Main Contacts | 3 |
Overall Height | 3.35 in |
Horsepower @ Three Phase - 208V AC | 7 1/2 hp |
Maximum Voltage Rating | 690V AC |
Minimum Operating Temperature | -40 Degrees F |
Mounting Style | DIN Rail, Plate |
Horsepower @ Single Phase - 120V AC | 2 hp |
Embedded Surge Suppressor | No |
NEMA Enclosure Material | Not Applicable |
Phase | Three |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 32 A Full Load Amps-Inductive, 208V AC, 50/60 Hz, 1NO/1NC, SCHNEIDER ELECTRIC, Mfr# LC1D32LE7
$197.44
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 208V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$197.44
You must be logged in to post a review.
Reviews
There are no reviews yet.