Discount -3%

IEC Magnetic Contactor, 3 Poles, 240 V AC, 40 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D40AU7

$282,99
-$8.49 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 240V AC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$282.99
Final shipping and tax calculated in checkout
Subtotal: $274.50 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D40AU7
Availability: Ships in 1 days
SKU: GRG3270337 Category:
Full Load Amps-Inductive40 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive60 A
ActionNon-Reversing
Number of Poles3
Coil Volts240 V AC
ReversingNo
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 230V5
HP @ 1 Phase - 240V5 hp
Height2.17 in
Width2.17 in
HP @ 3 Phase - 208V10 hp
HP @ 3 Phase - 575V30 hp
HP @ 3 Phase - 240V10 hp
Depth4.61 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V30 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
NEMA SizeNot Applicable
IncludesEverlink Power Connections
SeriesTeSys Deca
Operating Speed3600 cycles per hr
Switching Current5 mA (Signalling Circuit)
Rated Short-Time Withstand Current320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
IP RatingIP20
Operating Time4 to 19 ms (Opening), 12 to 26 ms (Closing)
Fire RatingUL 94 V1
Non-Overlap Time1.5 ms
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
FeaturesWithout Built-In Suppressor Module
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Signalling Circuit Frequency25 to 400 Hz
ApplicationMotor Control, Resistive Load
Rated Insulation Volts600/690V
Thermal Amperage10 A (at 60°C Signalling Circuit), 60 A (at 60°C Power Circuit)
Switching Voltage17 V (Signalling Circuit)
Net Weight0.85 kg
Inrush VA140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Overvoltage CategoryCAT III
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)
Electrical Durability1.4 Mcycles (60 A, AC-1, Less than 440 V), 1.5 Mcycles (40 A, AC-3, Less than 440 V), 1.5 Mcycles (40 A, AC-3e, Less than 440 V)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Includes Protective CoverYes
Max. Operating Watts18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Tightening Torque1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
Fuse Amps10 A (Signalling Circuit), 80 A (Type 1 Power Circuit), 80 A (Type 2 Power Circuit)
Mounts OnPlate, Rail
Electrical ConnectionScrew Clamp Terminals
Shock Resistance10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Impedance1.5 mOhm
Working HeightUp to 9842.52 ft
Mechanical Durability6 Mcycles
Max. Temperature850°C
Hold VA13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C)
Watts Loss4 to 5W
Impulse Withstand Voltage6 kV
Rated Voltage690V AC, 300V DC
Rated Breaking Capacity800 A @ 440V
Includes Auxiliary ContactsYes
NEMA Enclosure RatingNo Enclosure
Full Load Current - Resistive60 A
Overall Width2.17 in
Overall Depth4.72 in
Terminal Connection TypeScrew Clamp Terminals
Maximum Voltage Rating690V AC
NEMA Enclosure MaterialNot Applicable
Coil Voltage240V AC
Reversing CapabilityNon-Reversing
Horsepower @ Single Phase - 120V AC3 hp
Horsepower @ Three Phase - 240V AC10 hp
Resistance PropertiesFire Resistant, Insulation Resistant
Embedded Surge SuppressorNo
PhaseThree
Contactor StyleIEC
Mechanical Operating Durability6,000,000
Maximum Operating Temperature140 Degrees F
Number of Auxillary Contacts2
Horsepower @ Three Phase - 480V AC30 hp
Horsepower @ Single Phase - 240V AC5 hp
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 208V AC10 hp
Minimum Operating Temperature-40 Degrees F
Horsepower @ Three Phase - 600V AC30 hp
Full Load Current - Inductive40 A
Number of Normally Open Main Contacts3
Electrical Operating Durability1,400,000, 1,500,000
Overall Height4.8 in
Frequency50/60 Hz
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#240 V AC
#40 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D40AU7
#SCHNEIDER ELECTRIC
#GRG3270337
#mfr:LC1D40AU7
#part number:LC1D40AU7
#pn:LC1D40AU7
#part code:LC1D40AU7
#item number:LC1D40AU7
#product code:LC1D40AU7
#manufacturer number:LC1D40AU7
#manufacturers part number:LC1D40AU7
#mfn:LC1D40AU7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!