IEC Magnetic Contactor, 3 Poles, 24 V AC, 115 A, Reversing: No, SCHNEIDER, Mfr# LC1D115B7

$506,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 115 A, Full Load Current - Resistive 200 A, Reversing Capability Non-Reversing, Overall Height 6.22 in, Overall Width 0.47 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

Out of stock

Brand Name: SCHNEIDER
Mfr #: LC1D115B7
Availability: Ships in 1 days
SKU: GRG2593823 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive115 A
ActionNon-Reversing
Full Load Amps-Resistive200 A
Number of Poles3
Coil Volts24 V AC
ReversingNo
Height4.33 in
HP @ 3 Phase - 208V30 hp
Width4.72 in
HP @ 3 Phase - 240V40 hp
Depth6.22 in
HP @ 3 Phase - 575V100 hp
HP @ 3 Phase - 480V75 hp
Enclosure NEMA RatingNo Enclosure
Aux. Contact Configuration1NO/1NC
Hz50/60
Auxiliary Contact Form1NO/1NC
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
SeriesTeSys Deca
NEMA SizeNot Applicable
Shock Resistance15 G for 11 ms (Contactor Closed), 6 G for 11 ms (Contactor Open)
Net Weight2.5 kg
Operating Speed2400 cycles per hr
Electrical ConnectionScrew Clamp Terminals
Electrical Durability0.8 Mcycles (200 A, AC-1, Less than 440 V), 0.95 Mcycles (115 A, AC-3, Less than 440 V), 0.95 Mcycles (115 A, AC-3e, Less than 440 V)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.5 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.15 Uc (at -40-55°C 50/60 Hz), 1 to 1.15 Uc (at 55-70°C 50/60 Hz)
ApplicationMotor Control, Resistive Load
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Rated Making Capacity1260 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Rated Insulation Volts600/1000V (Power Circuit), 600/690V (Signalling Circuit)
Fire RatingUL 94 V1
Includes Protective CoverYes
Rated Breaking Capacity1100 A @ 440V
Impedance0.6 mOhm
Working HeightUp to 9842.52 ft
Switching Current5 mA (Signalling Circuit)
Impulse Withstand Voltage8 kV
Rated Voltage1000V AC, 300V DC
Mounts OnPlate, Rail
Watts Loss3 to 8W
Signalling Circuit Frequency25 to 400 Hz
Mechanical Durability8 Mcycles
Tightening Torque1.2 Nm (Control Circuit), 12 Nm (Power Circuit)
Fuse Amps250 A (Type 1 Power Circuit), 200 A (Type 2 Power Circuit), 10 A (Signalling Circuit)
Hold VA2 to 18 VA
Switching Voltage17 V (Signalling Circuit)
Max. Operating Watts30 kW (at 220 to 230V AC 50/60 Hz AC-3), 55 kW (at 380 to 400V AC 50/60 Hz AC-3), 59 kW 415 to (at 440V AC 50/60 Hz AC-3), 75 kW (at 500V AC 50/60 Hz AC-3), 80 kW (at 660 to 690V AC 50/60 Hz AC-3), 65 kW (at 1000V AC 50/60 Hz AC-3), 18.5 kW (at 400V AC 50/60 Hz AC-4), 30 kW (at 220 to 230V AC 50/60 Hz AC-3e), 55 kW (at 380 to 400V AC 50/60 Hz AC-3e), 59 kW 415 to (at 440V AC 50/60 Hz AC-3e), 75 kW (at 500V AC 50/60 Hz AC-3e), 80 kW (at 660 to 690V AC 50/60 Hz AC-3e), 65 kW (at 1000V AC 50/60 Hz AC-3e)
Non-Overlap Time1.5 ms
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Environmental AttributesMercury Free, PVC Free, Pollution Degree 3
Operating Time6 to 20 ms (Opening), 20 to 50 ms (Closing)
Max. Temperature850°C
Rated Short-Time Withstand Current250 A (at 40°C for 10 min Power Circuit), 550 A (at 40°C for 1 min Power Circuit), 950 A (at 40°C for 10 s Power Circuit), 1100 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Inrush VA280 to 350 VA
Overvoltage CategoryCAT III
IP RatingIP20
Thermal Amperage200 A (at 60°C Power Circuit)
Resistance PropertiesFire Resistant, Insulation Resistant
Embedded Surge SuppressorYes
Horsepower @ Three Phase - 208V AC30 hp
Horsepower @ Three Phase - 480V AC75 hp
Overall Width0.47 in
PhaseThree
NEMA Enclosure RatingNo Enclosure
Reversing CapabilityNon-Reversing
Contactor StyleIEC
Horsepower @ Three Phase - 240V AC40 hp
Minimum Operating Temperature-40 Degrees F
Number of Normally Open Main Contacts3
Coil Voltage24V AC
Includes Auxiliary ContactsYes
Mechanical Operating Durability8,000,000
Frequency50/60 Hz
Full Load Current - Inductive115 A
Electrical Operating Durability800,000, 950,000
Overall Height6.22 in
Horsepower @ Three Phase - 600V AC100 hp
Number of Auxillary Contacts2
NEMA Enclosure MaterialNot Applicable
Maximum Voltage Rating1000V AC
Mounting StyleDIN Rail, Plate
Terminal Connection TypeScrew Clamp Terminals
Maximum Operating Temperature140 Degrees F
Full Load Current - Resistive200 A
Overall Depth5.35 in
Horsepower @ Single Phase - 240V AC1 hp
Protective CoverWith
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Poles Description3P
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Protective TreatmentTHIEC 60068-2-30
Associated Fuse Rating250 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 200 A gG at Less than or Equal to 690 V coordination type 2 for power circuit, 10 A gG for signalling circuit
Rated Operational Current200 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 115 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Product CertificationsDNV, GOST, UL, CSA, CCC, LROS (Lloyds register of shipping), RINA, GL, BV, UKCA, CE
Fire Resistance1562°F (850°C) IEC 60695-2-1
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Average Impedance0.6 mOhm - Ith 200 A 50 Hz for power circuit
Mounting SupportRail, Plate
Motor Power KW30 kW at 220 to 230 V AC 50/60 Hz (AC-3), 55 kW at 380 to 400 V AC 50/60 Hz (AC-3), 59 kW at 415 to 440 V AC 50/60 Hz (AC-3), 75 kW at 500 V AC 50/60 Hz (AC-3), 80 kW at 660 to 690 V AC 50/60 Hz (AC-3), 65 kW at 1000 V AC 50/60 Hz (AC-3), 18.5 kW at 400 V AC 50/60 Hz (AC-4), 30 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 55 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 59 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 75 kW at 500 V AC 50/60 Hz (AC-3e), 80 kW at 660 to 690 V AC 50/60 Hz (AC-3e), 65 kW at 1000 V AC 50/60 Hz (AC-3e)
Control Circuit Voltage24 V AC 50/60 Hz
Compatibility CodeLC1D
Control Circuit TypeAC 50/60 Hz standard
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Power circuit 1000 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Maximum Horse Power Rating30 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 40 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 75 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 100 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Conventional Free Air Thermal Current200 A (at 140°F (60°C)) for power circuit
Utilisation CategoryAC-1, AC-4, AC-3, AC-3e
Product Or Component TypeContactor
Rated Operational VoltagePower circuit Less than or Equal to 1000 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Inrush Power in VA280 to 350 VA 60 Hz cos phi 0.8 (at 68°F (20°C)), 280 to 350 VA 50 Hz cos phi 0.8 (at 68°F (20°C))
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Auxiliary Contact Composition1 NO + 1 NC
Minimum Switching Voltage17 V for signalling circuit
Maximum Operating Rate2400 cyc/h 140°F (60°C)
Minimum Switching Current5 mA for signalling circuit
Safety Reliability LevelB10d = 684932 cycles contactor with nominal load EN/ISO 13849-1, B10d = 10000000 cycles contactor with mechanical load EN/ISO 13849-1
Rated Impulse Withstand Voltage8 kV IEC 60947
Pollution Degree3
Heat Dissipation3 to 8 W at 50/60 Hz
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Hold-In Power Consumption in VA2 to 18 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 2 to 18 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Contact CompatibilityM13
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 6 Gn for 11 ms)
IRMS Rated Making Capacity1260 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated Short Time Withstand Current250 A 104°F (40°C) - 10 min for power circuit, 550 A 104°F (40°C) - 1 min for power circuit, 950 A 104°F (40°C) - 10 s for power circuit, 1100 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: solid without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible without cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: flexible with cable end, Power circuit: connector 1 0.02 to 0.19 in? (10 to 120 mm?) - cable stiffness: solid without cable end, Power circuit: connector 2 0.02 to 0.08 in? (10 to 50 mm?) - cable stiffness: solid without cable end
Flame RetardanceV1 conforming to UL 94
Pole Contact Composition3 NO
Power Dissipation Per Pole24 W AC-1, 7.9 W AC-3, 7.9 W AC-3e
IP Degree Of ProtectionIP20 front face IEC 60529
Contactor ApplicationMotor control, Resistive load
Country of Origin (subject to change)Czechia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V AC
#115 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D115B7
#SCHNEIDER
#GRG2593823
#mfr:LC1D115B7
#part number:LC1D115B7
#pn:LC1D115B7
#part code:LC1D115B7
#item number:LC1D115B7
#product code:LC1D115B7
#manufacturer number:LC1D115B7
#manufacturers part number:LC1D115B7
#mfn:LC1D115B7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!