Full Load Amps-Inductive | 12 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 25 A |
Action | Non-Reversing |
Number of Poles | 3 |
Coil Volts | 480 V AC |
Reversing | No |
HP @ 1 Phase - 230V | 2 |
HP @ 1 Phase - 120V | 1 hp |
Height | 3.03 in |
HP @ 1 Phase - 240V | 2 hp |
Width | 1.77 in |
HP @ 3 Phase - 208V | 3 hp |
Depth | 3.38 in |
HP @ 3 Phase - 575V | 10 hp |
HP @ 3 Phase - 240V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 7 1/2 hp |
Aux. Contact Configuration | 1NO/1NC |
Hz | 50/60 |
Auxiliary Contact Form | 1NO/1NC |
Standards | BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed |
Series | TeSys Deca |
NEMA Size | Not Applicable |
Fuse Amps | 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit) |
Rated Insulation Volts | 600/690V |
Application | Motor Control, Resistive Load |
Watts Loss | 2 to 3W |
Electrical Durability | 2 Mcycles (12 A, AC-3, Less than 440 V), 0.8 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (12 A, AC-3e, Less than 440 V) |
Max. Operating Watts | 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Working Height | Up to 9842.52 ft |
Thermal Amperage | 25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit) |
Max. Temperature | 850°C |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Non-Overlap Time | 1.5 ms |
Switching Voltage | 17 V (Signalling Circuit) |
Rated Short-Time Withstand Current | 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Overvoltage Category | CAT III |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Operating Time | 12 to 22 ms (Closing), 4 to 19 ms (Opening) |
Rated Making Capacity | 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit) |
Hold VA | 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C) |
Operating Speed | 3600 cycles per hr |
Fire Rating | UL 94 V1 |
Rated Voltage | 690V AC, 300V DC |
Mounts On | Plate, Rail |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Inrush VA | 70 VA |
Mechanical Durability | 15 Mcycles |
Rated Breaking Capacity | 250 A @ 440V |
Impulse Withstand Voltage | 6 kV |
Electrical Connection | Screw Clamp Terminals |
Tightening Torque | 1.7 Nm |
Signalling Circuit Frequency | 25 to 400 Hz |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Switching Current | 5 mA (Signalling Circuit) |
Shock Resistance | 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open) |
Net Weight | 0.325 kg |
Includes Protective Cover | Yes |
Features | Without Built-In Suppressor Module |
Impedance | 2.5 mOhm |
IP Rating | IP20 |
Overall Depth | 3.39 in |
Electrical Operating Durability | 2,000,000, 800,000 |
Horsepower @ Single Phase - 240V AC | 2 hp |
Resistance Properties | Fire Resistant, Insulation Resistant |
Embedded Surge Suppressor | No |
Full Load Current - Resistive | 25 A |
Reversing Capability | Non-Reversing |
Full Load Current - Inductive | 12 A |
Contactor Style | IEC |
Phase | Three |
Coil Voltage | 480V AC |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Number of Normally Open Main Contacts | 3 |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
Horsepower @ Three Phase - 240V AC | 3 hp |
Mounting Style | DIN Rail, Plate |
Frequency | 50/60 Hz |
Horsepower @ Three Phase - 208V AC | 3 hp |
NEMA Enclosure Material | Not Applicable |
Maximum Voltage Rating | 690V AC |
Includes Auxiliary Contacts | Yes |
Overall Height | 3.03 in |
Maximum Operating Temperature | 140 Degrees F |
Minimum Operating Temperature | -40 Degrees F |
Overall Width | 1.77 in |
Number of Auxillary Contacts | 2 |
Mechanical Operating Durability | 15,000,000 |
Horsepower @ Three Phase - 600V AC | 10 hp |
NEMA Enclosure Rating | No Enclosure |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 480 V AC, 12 A, Reversing: No, SCHNEIDER, Mfr# LC1D12T7
$133.85
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 25 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$133.85
You must be logged in to post a review.
Reviews
There are no reviews yet.