Discount -3%

IEC Magnetic Contactor, 3 Poles, 480 V AC, 32 A, Reversing: No, SCHNEIDER, Mfr# LC1D32T7

$228,99
-$6.87 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 480V AC, Number of Poles 3, Full Load Current - Inductive 32 A, Full Load Current - Resistive 50 A, Reversing Capability Non-Reversing, Overall Height 3.35 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$228.99
Final shipping and tax calculated in checkout
Subtotal: $222.12 with subscription
Brand Name: SCHNEIDER
Mfr #: LC1D32T7
Availability: Ships in 1 days
SKU: GRG1793093 Category:
Full Load Amps-Inductive32 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive50 A
ActionNon-Reversing
Number of Poles3
Coil Volts480 V AC
ReversingNo
HP @ 1 Phase - 120V2 hp
HP @ 1 Phase - 230V5
Height3.36 in
HP @ 1 Phase - 240V5 hp
Width1.77 in
HP @ 3 Phase - 208V10 hp
HP @ 3 Phase - 240V10 hp
Depth3.62 in
HP @ 3 Phase - 575V30 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V20 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsBV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
NEMA SizeNot Applicable
Fire RatingUL 94 V1
Non-Overlap Time1.5 ms
Rated Insulation Volts600/690V
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 550 A @ 440V (Power Circuit)
Max. Temperature850°C
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Electrical ConnectionScrew Clamp Terminals
IP RatingIP20
Fuse Amps10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
Working HeightUp to 9842.52 ft
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Overvoltage CategoryCAT III
Switching Current5 mA (Signalling Circuit)
FeaturesWithout Built-In Suppressor Module
Tightening Torque1.7 Nm (Control Circuit), 2.5 Nm (Power Circuit)
Rated Voltage690V AC, 300V DC
ApplicationMotor Control, Resistive Load
Switching Voltage17 V (Signalling Circuit)
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Signalling Circuit Frequency25 to 400 Hz
Max. Operating Watts7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Mechanical Durability15 Mcycles
Thermal Amperage10 A (at 60°C Signalling Circuit), 50 A (at 60°C Power Circuit)
Electrical Durability1.65 Mcycles (32 A, AC-3, Less than 440 V), 1.4 Mcycles (50 A, AC-1, Less than 440 V), 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
Watts Loss2 to 3W
Operating Speed3600 cycles per hr
Impedance2 mOhm
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Time4 to 19 ms (Opening), 12 to 22 ms (Closing)
Rated Breaking Capacity550 A @ 440V
Inrush VA70 VA
Shock Resistance8 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Net Weight0.375 kg
Includes Protective CoverYes
Rated Short-Time Withstand Current60 A (at 40°C for 10 min Power Circuit), 138 A (at 40°C for 1 min Power Circuit), 260 A (at 40°C for 10 s Power Circuit), 430 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Impulse Withstand Voltage6 kV
Mounts OnPlate, Rail
Includes Auxiliary ContactsYes
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 208V AC7 1/2 hp
Terminal Connection TypeScrew Clamp Terminals
Overall Height3.35 in
Horsepower @ Three Phase - 240V AC10 hp
Electrical Operating Durability1,400,000, 1,650,000
Mechanical Operating Durability15,000,000
Reversing CapabilityNon-Reversing
Number of Normally Open Main Contacts3
Frequency50/60 Hz
Resistance PropertiesFire Resistant, Insulation Resistant
Horsepower @ Single Phase - 120V AC2 hp
PhaseThree
Horsepower @ Three Phase - 480V AC20 hp
Overall Width1.77 in
Embedded Surge SuppressorNo
Mounting StyleDIN Rail, Plate
Coil Voltage480V AC
Full Load Current - Resistive50 A
Horsepower @ Three Phase - 600V AC30 hp
Horsepower @ Single Phase - 240V AC5 hp
Contactor StyleIEC
Minimum Operating Temperature-40 Degrees F
NEMA Enclosure RatingNo Enclosure
Overall Depth3.62 in
Maximum Operating Temperature140 Degrees F
Full Load Current - Inductive32 A
Number of Auxillary Contacts2
Maximum Voltage Rating690V AC
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Protective CoverWith
Flame RetardanceV1 conforming to UL 94
Connections - TerminalsControl circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (1.5 to 10 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: solid without cable end
Contactor ApplicationResistive load, Motor control
IP Degree Of ProtectionIP20 front face IEC 60529
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor closed 15 Gn for 11 ms), Shocks contactor open 8 Gn for 11 ms)
Product CertificationsRINA, LROS (Lloyds register of shipping), GL, GOST, BV, CSA, CCC, UL, DNV
Control Circuit TypeAC 50/60 Hz
Protective TreatmentTHIEC 60068-2-30
Rated Impulse Withstand Voltage6 kV IEC 60947
Pole Contact Composition3 NO
Rated Operational Current32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 50 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Pollution Degree3
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Average Impedance2 mOhm - Ith 50 A 50 Hz for power circuit
Fire Resistance1562°F (850°C) IEC 60695-2-1
Motor Power KW7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3), 18.5 kW at 500 V AC 50/60 Hz (AC-3), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 7.5 kW at 400 V AC 50/60 Hz (AC-4), 7.5 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 15 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 15 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 18.5 kW at 500 V AC 50/60 Hz (AC-3e), 18.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Product Or Component TypeContactor
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 550 A at 440 V for power circuit conforming to IEC 60947
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Control Circuit Voltage480 V AC 50/60 Hz
Compatibility CodeLC1D
Contact CompatibilityM2
Minimum Switching Voltage17 V for signalling circuit
Rated Insulation VoltagePower circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL, Power circuit 690 V IEC 60947-4-1
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Mounting SupportRail, Plate
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 63 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 63 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Rated Short Time Withstand Current60 A 104°F (40°C) - 10 min for power circuit, 138 A 104°F (40°C) - 1 min for power circuit, 260 A 104°F (40°C) - 10 s for power circuit, 430 A 104°F (40°C) - 1 s for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Utilisation CategoryAC-4, AC-1, AC-3, AC-3e
Maximum Horse Power Rating2 hp at 115 V AC 50/60 Hz for 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 20 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 25 hp at 575/600 V AC 50/60 Hz for 3 phase motors
Heat Dissipation2 to 3 W at 50/60 Hz
Minimum Switching Current5 mA for signalling circuit
Power Dissipation Per Pole2 W AC-3, 5 W AC-1, 2 W AC-3e
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 50 A (at 140°F (60°C)) for power circuit
Poles Description3P
Auxiliary Contact Composition1 NO + 1 NC
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#480 V AC
#32 A
#Reversing: No
#SCHNEIDER
#Mfr LC1D32T7
#SCHNEIDER
#GRG1793093
#mfr:LC1D32T7
#part number:LC1D32T7
#pn:LC1D32T7
#part code:LC1D32T7
#item number:LC1D32T7
#product code:LC1D32T7
#manufacturer number:LC1D32T7
#manufacturers part number:LC1D32T7
#mfn:LC1D32T7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!