Full Load Amps-Inductive | 6 A |
Item | Miniature IEC Magnetic Contactor |
Action | Reversing |
Full Load Amps-Resistive | 15 A |
Number of Poles | 3 |
Coil Volts | 24 V AC |
Reversing | Yes |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 240V | 1 1/2 hp |
Height | 3.54 in |
HP @ 3 Phase - 208V | 1 1/2 hp |
Width | 3.54 in |
Depth | 1.97 in |
HP @ 3 Phase - 575V | 3 hp |
HP @ 3 Phase - 240V | 1 1/2 hp |
HP @ 3 Phase - 480V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NC |
Hz | 50/60 |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NC |
Series | TeSys K |
NEMA Size | Not Applicable |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
IP Rating | IP20 |
Operating Speed | 3600 cycles per hr |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Watts Loss | 1.3W |
Mounts On | Plate, Rail |
Rated Voltage | 690V AC |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Working Height | 6561.68 ft |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Application | Motor Control |
Inrush VA | 30 VA |
Overvoltage Category | CAT III |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Signalling Circuit Frequency | Less Than 400 Hz |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Switching Voltage | 17 V (Signalling Circuit) |
Net Weight | 0.39 kg |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Electrical Durability | 1.3 Mcycles (6 A, AC-3, Less than 440 V), 1.3 Mcycles (6 A, AC-3e, Less than 440 V) |
Impulse Withstand Voltage | 8 kV |
Electrical Connection | Screw Clamp Terminals |
Mechanical Durability | 5 Mcycles |
Features | Preassembled with Reversing Power Busbar |
Impedance | 3 mOhm |
Switching Current | 5 mA (Signalling Circuit) |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Tightening Torque | 0.8 to 1.3 Nm |
Rated Insulation Volts | 600/690V |
Rated Making Capacity | 110 A |
Max. Operating Watts | 1.5 kW (at 220 to 230V AC 50/60 Hz), 2.2 kW (at 380 to 415VAC 50/60 Hz), 3 kW (at 440V AC 50/60 Hz), 3 kW (at 480V AC 50/60 Hz), 3 kW (at 500 to 600V AC 50/60 Hz), 3 kW (at 660 to 690V AC 50/60 Hz) |
Hold VA | 4.5 VA |
Full Load Current - Inductive | 6 A |
Resistance Properties | Insulation Resistant |
Minimum Operating Temperature | -13 Degrees F |
Mounting Style | DIN Rail, Plate |
Overall Height | 2.28 in |
Mechanical Operating Durability | 5,000,000 |
Horsepower @ Three Phase - 208V AC | 1 1/2 hp |
Overall Depth | 2.24 in |
Maximum Voltage Rating | 690V AC |
Includes Auxiliary Contacts | Yes |
Number of Normally Open Main Contacts | 3 |
Number of Auxillary Contacts | 1 |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Reversing Capability | Reversing |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 240V AC | 1 1/2 hp |
Horsepower @ Three Phase - 480V AC | 3 hp |
Contactor Style | IEC |
Full Load Current - Resistive | 15 A |
Frequency | 50/60 Hz |
Maximum Operating Temperature | 122 Degrees F |
NEMA Enclosure Rating | No Enclosure |
Electrical Operating Durability | 1,300,000 |
Overall Width | 3.54 in |
NEMA Enclosure Material | Not Applicable |
Horsepower @ Three Phase - 600V AC | 3 hp |
Terminal Connection Type | Screw Clamp Terminals |
Coil Voltage | 24V AC |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 24 V AC, 6 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K0601B7
$136.76
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$136.76
You must be logged in to post a review.
Reviews
There are no reviews yet.