Full Load Amps-Inductive | 6 A |
Item | Miniature IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Resistive | 15 A |
Number of Poles | 3 |
Coil Volts | 240 V AC |
Reversing | No |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 240V | 1 1/2 hp |
Height | 1.73 in |
Width | 1.73 in |
HP @ 3 Phase - 208V | 1 1/2 hp |
Depth | 1.97 in |
HP @ 3 Phase - 575V | 3 hp |
HP @ 3 Phase - 240V | 1 1/2 hp |
HP @ 3 Phase - 480V | 3 hp |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | 1NO |
Hz | 50/60 |
Auxiliary Contact Form | 1NO |
Frame / Series / Class / Code | TeSys |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Series | TeSys K |
NEMA Size | Not Applicable |
Rated Voltage | 690V AC |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Control Circuit Voltage Limits | Operational: 0.85 to 1.1 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Operating Speed | 3600 cycles per hr |
Inrush VA | 30 VA |
Rated Making Capacity | 110 A |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Hold VA | 4.5 VA |
Rated Short-Time Withstand Current | 90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit) |
Electrical Durability | 1.3 Mcycles (6 A, AC-3, Less than 440 V), 1.3 Mcycles (6 A, AC-3e, Less than 440 V) |
Working Height | 6561.68 ft |
Electrical Connection | Screw Clamp Terminals |
Switching Current | 5 mA (Signalling Circuit) |
Mounts On | Plate, Rail |
Impulse Withstand Voltage | 8 kV |
Watts Loss | 1.3W |
Net Weight | 0.18 kg |
Overvoltage Category | CAT III |
IP Rating | IP22 |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Signalling Circuit Frequency | Less Than 400 Hz |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Switching Voltage | 17 V (Signalling Circuit) |
Application | Motor Control |
Tightening Torque | 0.8 to 1.3 Nm |
Mechanical Durability | 10 Mcycles |
Rated Breaking Capacity | 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V |
Rated Insulation Volts | 600/690V |
Operating Time | 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing) |
Impedance | 3 mOhm |
Max. Operating Watts | 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 2.2 kW (at 380 to 415V AC 50/60 Hz AC-3), 3 kW (at 440V AC 50/60 Hz AC-3), 3 kW (at 480V AC 50/60 Hz AC-3), 3 kW (at 500 to 600V AC 50/60 Hz AC-3), 3 kW (at 660 to 690V AC 50/60 Hz AC-3), 1.5 kW (at 400V AC 50/60 Hz AC-4), 1.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 2.2 kW(at 380 to 415V AC 50/60 Hz AC-3e), 3 kW (at 440V AC 50/60 Hz AC-3e), 3 kW (at 480V AC 50/60 Hz AC-3e), 3 kW (at 500 to 600V AC 50/60 Hz AC-3e), 3 kW (at 660 to 690V AC 50/60 Hz AC-3e) |
Contactor Style | IEC |
Coil Voltage | 230-240V AC |
Frequency | 50/60 Hz |
Overall Width | 1.77 in |
Resistance Properties | Insulation Resistant |
Horsepower @ Three Phase - 240V AC | 1 1/2 hp |
NEMA Enclosure Material | Not Applicable |
Reversing Capability | Non-Reversing |
Maximum Voltage Rating | 690V AC |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Full Load Current - Inductive | 6 A |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Three Phase - 208V AC | 1 1/2 hp |
Includes Auxiliary Contacts | Yes |
Overall Depth | 2.24 in |
Mechanical Operating Durability | 10,000,000 |
Full Load Current - Resistive | 15 A |
NEMA Enclosure Rating | No Enclosure |
Number of Auxillary Contacts | 1 |
Embedded Surge Suppressor | No |
Horsepower @ Three Phase - 480V AC | 3 hp |
Electrical Operating Durability | 1,300,000 |
Horsepower @ Single Phase - 240V AC | 1 1/2 hp |
Number of Normally Open Main Contacts | 3 |
Overall Height | 2.28 in |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 600V AC | 3 hp |
IRMS Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Poles Description | 3P |
Minimum Switching Voltage | 17 V for signalling circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Control Circuit Type | AC 50/60 Hz |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Maximum Operating Rate | 3600 cyc/h |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Non Overlap Distance | 0.02 in (0.5 mm) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Minimum Switching Current | 5 mA for signalling circuit |
Heat Dissipation | 1.3 W |
Auxiliary Contacts Type | Instantaneous 1 NO |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
IP Degree Of Protection | IP2X VDE 0106 |
Product Or Component Type | Contactor |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Utilisation Category | AC-3, AC-3e, AC-4 |
Power Pole Contact Composition | 3 NO |
Device Application | Control |
Motor Power KW | 1.5 kW 220 to 230 V AC 50/60 Hz AC-3, 2.2 kW 380 to 415 V AC 50/60 Hz AC-3, 3 kW 440/690 V AC 50/60 Hz AC-3, 1.5 kW 220 to 230 V AC 50/60 Hz AC-3e, 2.2 kW 380 to 415 V AC 50/60 Hz AC-3e, 3 kW 440/690 V AC 50/60 Hz AC-3e, 1.5 kW 220 to 230 V AC 50/60 Hz AC-4, 2.2 kW 380 to 415 V AC 50/60 Hz AC-4, 3 kW 440/690 V AC 50/60 Hz AC-4 |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Mounting Support | Rail, Plate |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Rated Operational Current | 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 6 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit |
Auxiliary Contact Composition | 1 NO |
Control Circuit Voltage | 230 to 240 V AC 50/60 Hz |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Rated Short Time Withstand Current | 90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 240 V AC, 6 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1K0610U7
$59,89
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 230-240V AC, Number of Poles 3, Full Load Current - Inductive 6 A, Full Load Current - Resistive 15 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$59.89
You must be logged in to post a review.
Reviews
There are no reviews yet.