Full Load Amps-Inductive | 12 A |
Item | Miniature IEC Magnetic Contactor |
Action | Non-Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 24 V DC |
Reversing | No |
HP @ 1 Phase - 120V | 1/2 hp |
HP @ 1 Phase - 230V | 1-1/2 |
HP @ 1 Phase - 240V | 2 hp |
Height | 1.77 in |
Width | 1.77 in |
HP @ 3 Phase - 240V | 3 hp |
HP @ 3 Phase - 575V | 10 hp |
Depth | 2.24 in |
Enclosure NEMA Rating | No Enclosure |
HP @ 3 Phase - 480V | 7 1/2 hp |
Aux. Contact Configuration | 1NO |
Hz | 50/60 |
Auxiliary Contact Form | 1NO |
Standards | CSA, UKCA, UL Listed |
Frame / Series / Class / Code | TeSys |
NEMA Size | Not Applicable |
Series | TeSys K |
Operating Speed | 3600 cycles per hr |
Impedance | 3 mOhm |
Net Weight | 0.225 kg |
Rated Making Capacity | 110 A (AC Signalling Circuit), 144 A (AC Power Circuit) |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Switching Current | 5 mA (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C) |
Application | Motor Control, Resistive Load |
Mounts On | Plate, Rail |
Electrical Durability | 1.3 Mcycles 12 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 12 A AC-3e Less than or Equal to 440 V, 0.3 Mcycles 20 A AC-1 Less than or Equal to 690 V, 0.02 Mcycles 72 A AC-4 Less than or Equal to 440 V |
Mechanical Durability | 10 Mcycles |
Overvoltage Category | CAT III |
Switching Voltage | 17 V (Signalling Circuit) |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
Impulse Withstand Voltage | 8 kV |
Rated Voltage | 690V AC |
Rated Insulation Volts | 600/690V |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Working Height | 6561.68 ft |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Operating Time | 30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening) |
Tightening Torque | 0.8 to 1.3 Nm |
Maximum Voltage Rating | 690V AC |
Horsepower @ Three Phase - 480V AC | 7 1/2 hp |
Includes Auxiliary Contacts | Yes |
Overall Height | 2.28 in |
Full Load Current - Resistive | 20 A |
Number of Auxillary Contacts | 1 |
Contactor Style | IEC |
Overall Width | 1.77 in |
Frequency | 50/60 Hz |
Full Load Current - Inductive | 12 A |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 600V AC | 10 hp |
Resistance Properties | Insulation Resistant |
NEMA Enclosure Material | Not Applicable |
Overall Depth | 2.24 in |
Maximum Operating Temperature | 122 Degrees F |
Number of Normally Open Main Contacts | 3 |
Embedded Surge Suppressor | No |
Mounting Style | DIN Rail, Plate |
Horsepower @ Three Phase - 240V AC | 3 hp |
Mechanical Operating Durability | 10,000,000 |
Horsepower @ Single Phase - 240V AC | 2 hp |
Coil Voltage | 24V DC |
Reversing Capability | Non-Reversing |
Minimum Operating Temperature | -13 Degrees F |
Terminal Connection Type | Screw Clamp Terminals |
Horsepower @ Single Phase - 120V AC | 1/2 hp |
Contactor Application | Resistive load, Motor control |
IP Degree Of Protection | IP2X |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Hold-In Power Consumption in W | 3 W 68°F (20°C) |
Power Pole Contact Composition | 3 NO |
Control Circuit Type | DC standard |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
IRMS Rated Making Capacity | 144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Auxiliary Contacts Type | Instantaneous 1 NO |
Motor Power KW | 3 kW 220 to 230 V AC 50/60 Hz AC-3, 5.5 kW 380 to 415 V AC 50/60 Hz AC-3, 5.5 kW 440 V AC 50/60 Hz AC-3, 4 kW 690 V AC 50/60 Hz AC-3, 3 kW 220 to 230 V AC 50/60 Hz AC-3e, 5.5 kW 380 to 415 V AC 50/60 Hz AC-3e, 5.5 kW 440 V AC 50/60 Hz AC-3e, 4 kW 690 V AC 50/60 Hz AC-3e, 3 kW 220 to 230 V AC 50/60 Hz AC-4, 5.5 kW 380 to 415 V AC 50/60 Hz AC-4, 5.5 kW 440 V AC 50/60 Hz AC-4 |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Auxiliary Contact Composition | 1 NO |
Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Maximum Operating Rate | 3600 cyc/h |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 in? (1.5 mm?)flexible with cable end |
Poles Description | 3P |
Rated Operational Voltage | Power circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz |
Inrush Power in W | 3 W 68°F (20°C)) |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Heat Dissipation | 1.3 W |
Permissible Ambient Air Temperature Around The Device | -40 to 158°F (-40 to 70°C) at Uc |
Utilisation Category | AC-3, AC-3e, AC-1, AC-4 |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Rated Short Time Withstand Current | 115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Minimum Switching Current | 5 mA for signalling circuit |
Mounting Support | Plate, Rail |
Product Or Component Type | Contactor |
Minimum Switching Voltage | 17 V for signalling circuit |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Mini Magnetic Contactor, 3 Poles, 24 V DC, 12 A, Reversing: No, SCHNEIDER, Mfr# LP1K1210BD
$109,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Must order in multiples of 1
Subtotal: