Promotion Restriction
Not eligible for promotion
Item - Infrared Thermometer
Infrared Thermometer
Focus Spot Size and Distance - Infrared
1 in @ 50 in
Temp. Range (F) - Infrared
-40 Degrees to 1472 Degrees
Temp. Range (C) - Infrared
-40 Degrees to 800 Degrees
Temp. Accuracy (F) - Infrared
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Temp. Accuracy (C) - Infrared
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Laser Sighting - Infrared
Single Dot
Calibration Certificate Included
No
Data Logging - Instrument
Yes
Display - IR Camera
Dot Matrix LCD
Standards
ATEX/IECEx, GOST, INMETRO, NEC-500/NEC-505, PCEC
Spectral Response
8.0 to 14 uM
Operating Temp. Range
32 Degrees to 122 Degrees F
Accuracy
+/-1.0 Degrees C or +/-1.0%
Includes
Hard Carrying Case, K Type Thermocouple Bead Probe
Special Features
Data Logs 99 Points
Calibration Certificate
No
Focus Spot Size and Distance
1
Spectral Response - Infrared
8.0 to 14.0um
Temp. Range (C)
-40 Degrees to 800 Degrees C
Alarm Indication
Audible/Visual
Memory - Instrument
Avg., Dif., Max., Min
Emissivity
Adjustable 0.10 to 1.00
Repeatability
+/-0.5 Degrees C or +/-0.5%
Temp. Range (F)
-40 Degrees to 1472 Degrees F
Resolution
0.1 Degrees F/C
Temperature Alarm - Thermometer
High, Low
Manufacturers Warranty Length
2 yr
Field of View
Not Applicable
Environmental Applications - Air Conditioners and Heat Pumps
Non-Medical
Features
Comes with a Conductive Case to Safely Carry the IR Thermometer Into Hazardous Areas, Intrinsically Safe Infrared and Contact Thermometer, Meets Intrinsically Safe Certifications in Class I Div. 1 and Div. 2 or Zone 1 and 2 Hazardous Environments
Temperature Alerts
High Temperature, Low Temperature
Digital Display Screen Type
LCD
Testing Functions
Minimum Temperature
Resolution Degrees F
0.1 Degrees F
Manufacturer Warranty Length
2 yr
Calibration Certificate Type
Not Certified
Maximum Emissivity Setting
1.00
Maximum Temperature Measured Degrees F
1,472 Degrees F
Laser Sighting Type
Single Dot
Includes Work Light
Work Light Included
Alert Type
Digital Display, Light, Sound
Number of Batteries Required
2
Resolution Degrees C
0.1 Degrees C
Minimum Operating Temperature Degrees F
32 Degrees F
Accuracy Degrees C
+/-1.0% of Reading or +/-1.0 Degrees Whichever is Greater
Secondary Measuring Method
Type K Thermocouple
Emissivity Adjustability
Adjustable
Intrinsic Safety
Intrinsically Safe
Maximum Operating Temperature Degrees F
122 Degrees F
Minimum Temperature Measured Degrees F
-40 Degrees F
Minimum Emissivity Setting
0.10
Distance To Spot Ratio
50:1
Minimum Temperature Measured Degrees C
-40 Degrees C
Maximum Temperature Measured Degrees C
800 Degrees C
Accuracy Degrees F
+/-1.0% of Reading or +/-2.0 Degrees Whichever is Greater
Country of Origin (subject to change)
China