Item
Indicating Pressure Transmitter
Power Required
18 to 30 V DC (3-Wire), 20 to 30 V DC (2-Wire)
Process Connection
1 in BSPP
Display
Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
IP Rating
IP67; IP68; IP69K
Wetted Materials
316L Stainless Steel, Ceramic, PTFE
Standards
3A, ACS, CE, EC 1935/2004, EHEDG Certified, FCM, FDA, IO-Link, Reg31, UKCA, UL Listed
Minimum Operating Temperature
-25 Degrees C
Features
High Temperature Resistance and High Protection Rating, Hygienic, Flush Design, Programmable Analog and Switching Output, Resistant to High-Pressure Cleaning with Aggressive Cleaning Agents, Robust Stainless Steel Design for the Requirements of the Food and Beverage Industry
For Use With Media Type
Gases, Liquids, Suspended Particles
Pressure Range
-1 bar to 10 bar
Process Connection Type
BSPP
Maximum Operating Temperature
80 Degrees C
Pressure Units
bar, Mpa, psi
Display Units
bar, Mpa, psi
Process Connection Gender
Male
Process Connection Size
1 in
Fitting Material
316L Stainless Steel
Electrical Connections
4-Pin M12 Connector
Manufacturer Warranty Length
5 yr
Response Time
3 msec, 7 msec, 30 msec
Storage Temperature Range
-40 Degrees to 100 Degrees C
Number of digital outputs
2
Vacuum resistance [mbar]
-1000
Permanent current rating of switching output DC [mA]
100
Dynamic response T05 / T09 [s]
u003c 35 / u003c 135; (DIN EN 60751 water ; u003e 0,9 m/s)
Analogue current output [mA]
4...20, invertible; (scalable)
Analogue end point
1...10 bar 14.5...145 psi 0.1...1 MPa
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Application
flush mountable for the food and beverage industry
Min. response time of switching output (dAP) [ms]
3
Ambient temperature [°C]
-25...80
Materials
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Min. pressure cycles
100 million
Set point SP
-0.99...10 bar -14.3...145 psi -0.099...1 MPa
Medium temperature [°C]
-25...150
Long-term stability [% of the span]
u003c± 0,1; (Turn down 1:1; per year)
Protection
IP 67; IP 68; IP 69K
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Min. bursting pressure
150 bar 2175 psi 15 MPa
Repeatability [% of the span]
u003c± 0,1; (with temperature fluctuations u003c 10 K; Turn down 1:1)
IO-Link resolution pressure [bar]
0.0005
Special feature
Gold-plated contacts
Min. process cycle time [ms]
5.6
Transmission type
COM2 (38,4 kBaud)
In steps of
0.01 bar 0.1 psi 0.001 MPa
Factory setting
SP1 = 2.50 bar rP1 = 2.30 bar SP2 = 7.50 bar rP2 = 7.30 bar ASP = 0.00 bar AEP = 10.00 bar dAP = 0.06 s dAA = 0.06 s
Pressure rating
50 bar 725 psi 5 Mpa
Type of pressure
relative pressure; vacuum
IO-Link functions (acyclical)
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Power-on delay time [s]
u003c 0.5, u003c 1
Reverse polarity protection
yes
Switch point accuracy [% of the span]
u003c± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Damping for the analogue output dAA [s]
0...99.99
Max. voltage drop switching output DC [V]
2
Profiles
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
Total deviation over temperature range
Temperature range total deviation -25...15°C Characteristics deviation± 0,05 % der Spanne / 10 K 15...80°C Characteristics deviation 80...150°C Characteristics deviation± 0,1 % der Spanne / 10 K
Number of analogue outputs
1
IO-Link resolution temperature [K]
0.2
Communication interface
IO-Link
Analogue start point
-1...8 bar -14.5...116 psi -0.1...0.8 MPa
Damping process value dAP [s]
0...99.99
Linearity deviation [% of the span]
u003c± 0,15; (Turn down 1:1)
Short-circuit protection
yes
Display unit
bar; psi; MPa
UL approval
UL Approval no. J048 File number UL E174189
Accuracy [K]
± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Storage temperature [°C]
-40...100
Reset point rP
-1...9.99 bar -14.5...144.8 psi -0.1...0.999 MPa
Required master port type
A
Min. difference between SP and rP
0.02 bar 0.3 psi 0.002 MPa
Output signal
switching signal; analogue signal; IO-Link
Type of short-circuit protection
pulsed
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
Media
viscous media and liquids with suspended particles; liquids and gases
Switching frequency DC [Hz]
125
Min. insulation resistance [MΩ]
100; (500 V DC)
Step response time analogue output [ms]
7, 30
Operating voltage [V]
18...30 DC, 20...30 DC
IO-Link process data (cyclical)
function bit length pressure 32 temperature 32 device status 4 binary switching information 2
Current consumption [mA]
3.5...21.5, 5...45; (430 bei max. Laststrom)
Max. load [Ω]
300, (Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V)
Hysteresis deviation [% of the span]
u003c± 0,15; (Turn down 1:1)
Measuring range
-1...10 bar -14.6...145 psi -0.1...1 MPa, -25...150°C -13...302°F
Characteristics deviation [% of the span]
u003c± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Output function
normally open / normally closed; (parameterisable)
Materials (wetted parts)
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra u003c 0,4 / Rz 4; PTFE
Country of Origin (subject to change)
Germany