Item
Indicating Pressure Transmitter
Power Required
18 to 30 V DC (3-Wire), 20 to 30 V DC (2-Wire)
Process Connection
1 in BSPP
Display
Display unit LED, green switching status LED, yellow function display alphanumeric display, 4-digit measured values alphanumeric display, 4-digit
IP Rating
IP67; IP68; IP69K
Wetted Materials
316L Stainless Steel, Ceramic, PTFE
Standards
3A, ACS, CE, EC 1935/2004, EHEDG Certified, FCM, FDA, IO-Link, Reg31, UKCA, UL Listed
Process Connection Gender
Male
Electrical Connections
4-Pin M12 Connector
For Use With Media Type
Gases, Liquids, Suspended Particles
Response Time
3 msec, 7 msec, 30 msec
Process Connection Type
BSPP
Pressure Range
-12.4 mbar to 250 mbar
Maximum Operating Temperature
80 Degrees C
Minimum Operating Temperature
-25 Degrees C
Minimum Pressure
-12.4 mbar
Manufacturer Warranty Length
5 yr
Fitting Material
316L Stainless Steel
Features
High Temperature Resistance and High Protection Rating, Hygienic, Flush Design, Programmable Analog and Switching Output, Resistant to High-Pressure Cleaning with Aggressive Cleaning Agents, Robust Stainless Steel Design for the Requirements of the Food and Beverage Industry
Pressure Units
inH2O, kPa, mbar, mmWS
Process Connection Size
1 in
Display Units
inH2O, kPa, mbar, mmWS
Storage Temperature Range
-40 Degrees to 100 Degrees C
IO-Link process data (cyclical)
function bit length pressure 32 temperature 32 device status 4 binary switching information 2
UL approval
UL Approval no. J048 File number UL E174189
In steps of
0.1 mbar 0.1 inH2O 0.01 kPa 1 mmWS
Transmission type
COM2 (38,4 kBaud)
Characteristics deviation [% of the span]
u003c± 0,2; (DIN IEC EN 62828-1 incl. zero point and span error, non-linearity, hysteresis; Turn down 1:1)
Measuring range
-25...150°C -13...302°F, -12.4...250 mbar -5...100.4 inH2O -1.24...25 kPa -126...2550 mmWS
Min. process cycle time [ms]
5.6
Special feature
Gold-plated contacts
Min. response time of switching output (dAP) [ms]
3
Power-on delay time [s]
u003c 1, u003c 0.5
Accuracy [K]
± 2,5+ (0,08 x ( Umgebungstemperatur - Mediumtemperatur ))
Analogue start point
-12.4...199.4 mbar -5...80.1 inH2O -1.24...19.94 kPa -126...2033 mmWS
Hysteresis deviation [% of the span]
u003c± 0,15; (Turn down 1:1)
Repeatability [% of the span]
u003c± 0,1; (with temperature fluctuations u003c 10 K; Turn down 1:1)
Step response time analogue output [ms]
7, 30
Type of short-circuit protection
pulsed
Dynamic response T05 / T09 [s]
u003c 35 / u003c 135; (DIN EN 60751 water ; u003e 0,9 m/s)
Display unit
mbar; kPa; inH2O; mmWS
Required master port type
A
Analogue end point
38.2...250 mbar 15.3...100.4 inH2O 3.82...25 kPa 390...2549 mmWS
Permanent current rating of switching output DC [mA]
100
Max. voltage drop switching output DC [V]
2
Materials (wetted parts)
ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra u003c 0,4 / Rz 4; PTFE
Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
IO-Link resolution pressure [mbar]
0.01
Current consumption [mA]
3.5...21.5, 5...45; (430 bei max. Laststrom)
Number of analogue outputs
1
Storage temperature [°C]
-40...100
Min. insulation resistance [MΩ]
100; (500 V DC)
Operating voltage [V]
20...30 DC, 18...30 DC
Materials
stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA
Linearity deviation [% of the span]
u003c± 0,15; (Turn down 1:1)
Analogue current output [mA]
4...20, invertible; (scalable)
IO-Link functions (acyclical)
application specific tag; internal temperature; operating hours counter; switching cycles counter; Pressure peak counter
IO-Link resolution temperature [K]
0.2
Switch point accuracy [% of the span]
u003c± 0,2; (DIN EN IEC 62828-1; Turn down 1:1)
Connection
Connector: 1 x M12; coding: A; Contacts: gold-plated
Max. load [Ω]
(Ub - 10 V) / 21,5 mA; 650 Ω (Ub = 24 V), 300
Min. pressure cycles
100 million
Number of digital outputs
2
Media
viscous media and liquids with suspended particles; liquids and gases
Shock resistance
DIN EN 60068-2-27 50 g (11 ms)
Short-circuit protection
yes
Vibration resistance
DIN EN 60068-2-6 20 g (10...2000 Hz)
Protection
IP 67; IP 68; IP 69K
Profiles
Identification and Diagnosis (0x4000), Measurement Data Channel (0x800A)
Set point SP
-12...250 mbar -4.8...100.4 inH2O -1.2...25 kPa -122...2549 mmWS
Reverse polarity protection
yes
Application
flush mountable for the food and beverage industry
Damping process value dAP [s]
0...99.99
Output function
normally open / normally closed; (parameterisable)
Communication interface
IO-Link
Min. difference between SP and rP
0.5 mbar 0.2 inH2O 0.05 kPa 5 mmWS
Long-term stability [% of the span]
u003c± 0,1; (Turn down 1:1; per year)
Ambient temperature [°C]
-25...80
Vacuum resistance [mbar]
-1000
Factory setting
SP1 =62.5 mbar rP1 = 57.5 mbar SP2 = 187.5 mbar rP2 = 182.5 mbar ASP = 0.00 mbar AEP = 250 mbar dAP = 2.00 s dAA =2.00 s
Switching frequency DC [Hz]
125
Reset point rP
-12.4...249.6 mbar -5...100.2 inH2O -1.24...24.96 kPa -126...2545 mmWS
Damping for the analogue output dAA [s]
0...99.99
Pressure rating
6000 mbar 2400 inH2O 600 kPa
Output signal
switching signal; analogue signal; IO-Link
Total deviation over temperature range
Temperature range total deviation -25...15°C Characteristics deviation± 0,1 % der Spanne / 10 K 15...80°C Characteristics deviation 80...150°C Characteristics deviation± 0,15 % der Spanne / 10 K
Min. bursting pressure
30000 mbar 12044 inH2O 3000 kPa
Medium temperature [°C]
-25...150
Type of pressure
relative pressure; vacuum
Country of Origin (subject to change)
Germany