Output Voltage
110/115/120V AC
Backup Time (Half/Full Load)
11 min/3 min
Outlet Type
(6) Surge; (6) UPS/Surge
Automatic Volts Regulation
No
Standards
CSA, FCC Part 15 Category B (EMI), NOM, UL 1778
NEMA Receptacle Configuration
(12) 5-15R
Special Features
USB Port And Poweralert Software Enables Unattended Shutdown In Case Of Extended Power Failure
NEMA Plug Configuration
5-15P
VA Rating - UPS Systems
750.0 VA
Green Environmental Attribute
Product Contributes To Reducing Energy Consumption
Fax/Modem Line Protection
No
Input Connection
6 ft Cord with NEMA 5-15P Plug
Battery Type
Valve Regulated Lead Acid (VRLA)
UPS Power Module Dimensions (hwd, in.)
4.14 x 7.48 x 12
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
UPS Input Cord Length (ft.)
5
Operating Elevation (m)
Up to 3000m
PowerAlert Software
For local monitoring via the UPSâ„¢s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
High Availability UPS Features
Battery Independent Restart
Nominal Output Voltage(s) Supported
110V; 115V; 120V
Rated input current (Maximum Load)
10A
Output Watt Capacity (Watts)
450
Battery Recharge Rate (Included Batteries)
8 hours (10% to 90%)
Primary UPS Height (mm)
105
Overvoltage Correction
Input voltages between 128 and 145 are reduced by 15%
Primary Form Factor
Desktop
UPS AC Suppression Response Time
Instantaneous
Output Voltage Regulation (Battery Mode)
120V (±10%)
Battery Replacement Description
Replaceable internal batteries (see manual)
Primary UPS Depth (mm)
305
Storage Temperature Range
+5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius
Output Voltage Regulation (Line Mode)
120V (+6%/-12%)
UPS Dataline Suppression
1 line TEL/DSL or Ethernet
Input Circuit Breakers
10A
LED Indicators
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions
Battery Access
Battery access door
AC Mode Efficiency Rating (100% Load)
u003e96%
Recommended Electrical Service
15A 120V
Nominal Input Voltage(s) Supported
120V AC
Output AC Waveform (Battery Mode)
PWM sine wave
Relative Humidity
0 to 90%, non-condensing
Half Load Runtime (min.)
11 min. (225w)
Cold Start (Startup in Battery Mode During a Power Failure)
Cold-start operation supported
Individually Controllable Load Banks
No
Internal UPS Replacement Battery Cartridge
RBC51
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145
AC Mode BTU / Hr. (Full Load)
41
Output Volt Amp Capacity (VA)
750
Audible Alarm
UPS remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
UPS AC Suppression Joule Rating
316
Switches
Power off/on switch
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Frequency Compatibility
50 / 60 Hz
High Voltage Transfer to Battery Power (Setpoint)
145
Full Load Runtime (min.)
3 min. (450w)
UPS Certifications
Meets FCC Part 15 Category A (EMI); Tested to CSA (Canada); Tested to NOM (Mexico); Tested to UL1778 (USA)
Installation Form Factors Supported with Included Accessories
Tower; Ultra-compact desktop; Wallmount
Operating Elevation (ft.)
Up to 10,000 ft.
Low Voltage Transfer to Battery Power (Setpoint)
89
DC System Voltage (VDC)
12
EMI / RFI AC Noise Suppression
Yes
Communications Cable
USB interface cable included
Undervoltage Correction
Input voltages between 89 and 108 are boosted by 18%
UPS Certification Details
UL1778: 2014 5th EDITION; CAN/CSA-C22.2 NO. 107.3:2014 3rd EDITION; FCC CLASS A; FCC Part 68 Approved (#5WSWP01B005); Industry Canada Approved (#3449A-005, REN0.1B); RETIE (Colombia)
Communications Interface
USB (HID enabled)
Grounding Lug
Includes side panel grounding lug
Backup/Run Time (Half Load)
11 Minute
Certifications u0026 Standards
Energy Star
Maximum Operating Temperature
104°F (40°C)
Application/Usage
Printer, Home Theater, Home/Office, Router, TV, Digital Signage, Security System, ATM, Media Center, Computer, Blu-ray Player, Gaming Console
Alarm
Battery Backup, Low Battery, Overload, Replace Battery, Fault
Typical Battery Recharge Time
9 Hour
Energy Saving
Greater than 95% efficiency - GREEN UPS
AVR Range
Boost +18% / Buck -15%
Waveform Type
Pulse-width Modulated Sine Wave
Number of Battery u0026 Surge Outlets
6
Package Contents
AVR 750VA Desktop UPS, USB cable, Instruction manual
Maximum Operating Elevation
10000 ft
Status Indicators
2 Status LEDs; GREEN indicates power status and operating mode / RED indicates battery-low, overload, replace-battery and fault conditions
USB (HID Compliant) Port
Yes
Storage Temperature
5°F (-15°C) - 113°F (45°C)
Number of Surge-only Outlets
6
Load Capacity
750 VA/450 W
Form Factor
Ultra-compact Desktop/Tower/Wall Mount
Package Includes
AVR750U 750VA 450W 120V Line-Interactive UPS with 12 Outlets;USB cable;Owner's manual
Grounding Details
Includes side panel grounding lug
UPS Dataline Suppression Details
Set of two 8 position RJ connectors protect either a single 10BaseT connection (pins 1,2,3 u0026 6; 7.5V clamping) or a single TEL/DSL connection (pins 4-5; 260V clamping)
Product Certifications
RETIE (Colombia); CSA (Canada); NOM (Mexico); UL 1778
Product Compliance
FCC Part 15 Class A (USA)
Output Capacity (Watts)
450
UPS Applications
Home/Office Desktop; Audio/Video; Retail/Point of Sale; Hospitality
Country of Origin (subject to change)
Viet Nam