Item | Load Center |
Enclosure NEMA Rating | 1 |
Main Circuit Breaker or Main Lug | Main Lug |
Number of Spaces | 2 |
Phase | 1 |
Voltage | 120/240V AC |
Circuit Breaker Type | QO |
Max. No. of Tandem Breakers | 2 |
Height | 9.3 in |
Width | 4.8 in |
Amps | 70 A |
Bus Material | Tin Plated Aluminum |
Series | QO |
Depth | 3 1/4 in |
Special Features | Green Premium Product, Mercury Free, Toxic Heavy Metal Free |
Enclosure Material | Steel |
Short Circuit Current Rating | 65kA |
Recommended Surface Cover | Included |
Standards | RoHS Compliant, UL Listed |
Recommended Ground Bar Kit | 5B718 |
Cover Attachment Style | Screw On |
For Use With | Square D QO Circuit Breakers |
Color | Gray |
Min. Operating Temp. | 23 Degrees F |
Feed Location | Top/Bottom |
Cover Closure Method | Lift-Off |
Location | Indoor |
Enclosure Surface Finish | Enamel |
Included Enclosure Cover | Surface Cover |
Max. Operating Temp. | 104 Degrees F |
Voltage Rating | 120/240 V AC |
Enclosure Rating | NEMA 1 indoor |
Tightening Torque | main lugs 35 lb.in, AWG 14...AWG 10, aluminium/copper || main lugs 45 lb.in, AWG 3, aluminium/copper || main lugs 40 lb.in, AWG 8...AWG 4, aluminium/copper || main lugs 35 lb.in, AWG 12...AWG10, aluminium/copper |
Wire Size | AWG 12...AWG 3 aluminium || AWG 14...AWG 4 copper |
Ground Bar Kit | grounding bar (ordered separately) |
Electrical Connection | lugs |
Surface Finish | baked enamel Gray |
Wiring Configuration | 3-wire |
Primary/Ambient Air Temp. | -5°C || 40°C |
Cover Type | surface cover |
Number Of Circuits | 4 |
Ambient Air Temperature For Operation | 23°F (-5°C), 104°F (40°C) |
Max Short Circuit Current Rating | 65 kA |
Number Of Phases | 1 phase |
Busbar Material | Tin plated aluminium: busbar |
Product Certifications | UL Listed |
Box Number | 2 |
PoN Convertible Mains | Fixed Mains (lugs) |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Load Center, 2 Spaces, 70 A Amps, 120/240V AC, QO Circuit Breaker Type, SQUARE D, Mfr# QO24L70S
$35,85
Free shipping will be applied on orders over $50
Load Center, Number of Spaces 2, Amps 70 A, Voltage 120/240V AC, Circuit Breaker Type QO, Included Enclosure Cover Surface Cover, Main Circuit Breaker or Main Lug Main Lug, Max. No. of Tandem Breakers 2, Phase 1, Series QO, Height 9.3 in, Width 4.8 in, Depth 3 1/4 in, For Use With Square D QO Circuit Breakers, Bus Material Tin Plated Aluminum, Short Circuit Current Rating 65kA, Enclosure NEMA Rating 1, Cover Attachment Style Screw On, Cover Closure Method Lift-Off
9999 in stock
Must order in multiples of 1
Subtotal:
$35.85
You must be logged in to post a review.
Reviews
There are no reviews yet.