Manual Motor Starter, NEMA Size Not Applicable, Horsepower @ Single Phase - 120V AC 1/2 hp, Horsepower @ Single Phase - 240V AC 1 1/2 hp, Maximum Voltage Rating 690V AC, Number of Poles 3, Operator Push Button, Phase Three, Current AC 10 A, Horsepower @ Three Phase - 208V AC 2 hp, Horsepower @ Three Phase - 240V AC 3 hp, Horsepower @ Three Phase - 480V AC 5 hp, Series TeSys Deca, Horsepower @ Three Phase - 600V AC 7 1/2 hp, Maximum Overload Relay Current Setting 10 A

9999 in stock

Must order in multiples of 1
Subtotal:
$180.99
Final shipping and tax calculated in checkout
Subtotal: $180.41 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: GV2ME14
Availability: Ships in 1 days
SKU: GRG1814373 Category:
OperatorPush Button
NEMA SizeNot Applicable
Enclosure NEMA RatingNo Enclosure
Depth2.6 in
Amps AC6 to 10
Height3.5 in
Overload Relay Amp Setting6 to 10A
Width1.75 in
ItemManual Motor Starter
Number of Poles3
HP @ 3 Phase - 480V5 hp
Max. Voltage600V AC
HP @ 1 Phase - 120V1/2 hp
HP @ 3 Phase - 240V3 hp
Pilot LightNo
HP @ 3 Phase - 208V2 hp
Description/Special FeaturesMelting Alloy Thermal Overload, Single Unit
HP @ 3 Phase - 460-575V5/7.5
StandardsATEX Compliant, BV, CCC, CSA, DNV-GL, EAC, EN/IEC 60947-2, EN/IEC 60947-4, LROS, RINA, UKCA, UL Listed
HP @ 3 Phase - 575V7 1/2 hp
HP @ 1 Phase - 230V1 1/2 hp
Phase Loss SensitivityYes
Ambient Air Temperature For Operation-20-60°C
[Ics] Rated Service Short-Circuit Breaking Capacity100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2
Product CertificationsCCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA
Poles Description3P
Fire Resistance960°C IEC 60695-2-11
Magnetic Tripping Current138-138 A
Climatic WithstandIACS E10
Electrical Durability100000 cycles AC-3 415 V In
Power Dissipation Per Pole2.5 W
[Ue] Rated Operational Voltage690 V AC 50/60 Hz IEC 60947-2
Phase Failure Sensitivityyes IEC 60947-4-1
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-2
Motor Power Kw3-3 kW 400/415 V AC 50/60 Hz || 4-4 kW 400/415 V AC 50/60 Hz || 4-4 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 500 V AC 50/60 Hz || 5.5-5.5 kW 690 V AC 50/60 Hz || 7.5-7.5 kW 690 V AC 50/60 Hz
Thermal Protection Adjustment Range6-10 A IEC 60947-4-1
Utilisation Categorycategory A IEC 60947-2 || AC-3 IEC 60947-4-1
Ambient Air Temperature For Storage-40-80°C
Device Applicationmotor protection
Network Frequency50/60 Hz IEC 60947-4-1
Ik Degree Of ProtectionIK04
Breaking Capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 10 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2
Mechanical Robustnessshocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz
[Ui] Rated Insulation Voltage690 V AC 50/60 Hz IEC 60947-2
Product Or Component Typemotor circuit breaker
Rated Dutycontinuous IEC 60947-4-1
RangeTeSys Deca
Network TypeAC
Device Short NameGV2ME
Ip Degree Of ProtectionIP20 IEC 60529
Fixing Mode35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate)
Suitability For Isolationyes IEC 60947-1§ 7-1-6
Product NameTeSys GV2 || TeSys Deca
Trip Unit Technologythermal-magnetic
Tightening Torque1.7 N.m screw clamp terminal
Line Rated Current10A
[Ith] Conventional Free Air Thermal Current10 A IEC 60947-4-1
Control Typepush-button
Colordark grey
Operating Altitude6561.68 ft (2000 m)
Mechanical Durability100000 cycles
Maximum Overload Relay Current Setting10 A
Horsepower @ Three Phase - 480V AC5 hp
Horsepower @ Three Phase - 240V AC3 hp
Overall Height3.5 in
Mechanical Operating Durability100,000
Horsepower @ Single Phase - 120V AC1/2 hp
IP RatingIP20
Overall Width1.77 in
Includes Pilot LightNo
Frequency50/60 Hz
Minimum Overload Relay Current Setting6 A
Maximum Voltage Rating690V AC
SeriesTeSys Deca
Overload Protection TypeThermal
Electrical Operating Durability100,000
Resistance PropertiesFire Resistant
Status IndicatorNo Indicator
PhaseThree
Overall Depth3.09 in
NEMA Enclosure RatingNo Enclosure
Horsepower @ Three Phase - 600V AC7 1/2 hp
Terminal Connection TypeScrew Clamp Terminals
Maximum Operating Temperature140 Degrees F
Minimum Operating Temperature-4 Degrees F
Horsepower @ Single Phase - 240V AC1 1/2 hp
Current AC10 A
Starter StyleIEC
Horsepower @ Three Phase - 208V AC2 hp
Rated Service Short-Circuit Breaking Capacity100% 230/240 V AC 50/60 Hz IEC 60947-2, 100% 400/415 V AC 50/60 Hz IEC 60947-2, 100% 440 V AC 50/60 Hz IEC 60947-2, 100% 500 V AC 50/60 Hz IEC 60947-2, 75% 690 V AC 50/60 Hz IEC 60947-2
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#Manual Motor Starter
#Button
#6-10A
#SCHNEIDER ELECTRIC
#Mfr GV2ME14
#SCHNEIDER ELECTRIC
#GRG1814373
#mfr:GV2ME14
#part number:GV2ME14
#pn:GV2ME14
#part code:GV2ME14
#item number:GV2ME14
#product code:GV2ME14
#manufacturer number:GV2ME14
#manufacturers part number:GV2ME14
#mfn:GV2ME14

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!