Operator | Selector Switch |
NEMA Size | Not Applicable |
Enclosure NEMA Rating | No Enclosure |
Depth | 3.83 in |
Overload Relay Amp Setting | 1 to 1.6A |
Height | 3.5 in |
Item | Manual Motor Starter |
Width | 1.75 in |
Number of Poles | 3 |
HP @ 3 Phase - 480V | 3/4 hp |
Max. Voltage | 600V AC |
Pilot Light | Yes |
Phase Loss Sensitivity | Yes |
HP @ 1 Phase - 230V | 1/10 hp |
HP @ 3 Phase - 460-575V | 0.75/1 |
HP @ 3 Phase - 575V | 1 hp |
Description/Special Features | Reliable Overload Protection |
Standards | ATEX Compliant, BV, CCC, CSA, DNV-GL, EAC, EN/IEC 60947-2, EN/IEC 60947-4, LROS, RINA, UKCA, UL Listed |
Phase Failure Sensitivity | yes IEC 60947-4-1 |
Fire Resistance | 960°C IEC 60695-2-11 |
Product Or Component Type | motor circuit breaker |
Operating Altitude | 6561.68 ft (2000 m) |
Range | TeSys Deca |
Ik Degree Of Protection | IK04 |
Device Short Name | GV2P |
[Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
Utilisation Category | category A IEC 60947-2 || AC-3 IEC 60947-4-1 |
[Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
Product Name | TeSys GV2 || TeSys Deca |
Tightening Torque | 1.7 N.m screw clamp terminal |
Poles Description | 3P |
Control Type | rotary handle |
Breaking Capacity | 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 100 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
Mechanical Durability | 100000 cycles |
Color | dark grey |
Ambient Air Temperature For Storage | -40-80°C |
Fixing Mode | 35 mm symmetrical DIN rail clipped || panel screwed with 2 x M4 screws) |
Motor Power Kw | 0.37-0.37 kW 400/415 V AC 50/60 Hz || 0.55-0.55 kW 400/415 V AC 50/60 Hz || 0.37-0.37 kW 500 V AC 50/60 Hz || 0.55-0.55 kW 500 V AC 50/60 Hz || 0.75-0.75 kW 690 V AC 50/60 Hz |
Power Dissipation Per Pole | 2.5 W |
Thermal Protection Adjustment Range | 1-1.6 A IEC 60947-4-1 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-2 |
Network Type | AC |
Device Application | motor protection |
Suitability For Isolation | yes IEC 60947-1§ 7-1-6 |
Ambient Air Temperature For Operation | -20-60°C |
Magnetic Tripping Current | 22.5-22.5 A |
Electrical Durability | 100000 cycles AC-3 415 V In |
Mechanical Robustness | shocks 30 Gn for 11 ms || vibrations 5 Gn, 5...150 Hz |
Line Rated Current | 1.6 A |
Product Certifications | CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA |
Trip Unit Technology | thermal-magnetic |
Network Frequency | 50/60 Hz IEC 60947-4-1 |
Ip Degree Of Protection | IP20 IEC 60529 |
[Ics] Rated Service Short-Circuit Breaking Capacity | 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 100 % 400/415 V AC 50/60 Hz IEC 60947-2 || 100 % 440 V AC 50/60 Hz IEC 60947-2 || 100 % 500 V AC 50/60 Hz IEC 60947-2 || 100 % 690 V AC 50/60 Hz IEC 60947-2 |
Climatic Withstand | IACS E10 |
[Ith] Conventional Free Air Thermal Current | 1.6 A IEC 60947-4-1 |
Rated Duty | continuous IEC 60947-4-1 |
Overload Protection Type | Thermal |
Includes Pilot Light | No |
Frequency | 50/60 Hz |
Minimum Overload Relay Current Setting | 1 A |
Horsepower @ Three Phase - 480V AC | 3/4 hp |
Maximum Voltage Rating | 600V AC |
Overall Height | 3.5 in |
Electrical Operating Durability | 100,000 |
Minimum Operating Temperature | -4 Degrees F |
IP Rating | IP20 |
Terminal Connection Type | Screw Clamp Terminals |
Phase | Three |
Resistance Properties | Fire Resistant |
Mechanical Operating Durability | 100,000 |
Current AC | 1.6 A |
Series | TeSys Deca |
Maximum Operating Temperature | 140 Degrees F |
Status Indicator | LED Indicator |
Maximum Overload Relay Current Setting | 1.6 A |
Overall Depth | 3.82 in |
Starter Style | IEC |
Horsepower @ Single Phase - 240V AC | 1/10 hp |
Overall Width | 1.77 in |
NEMA Enclosure Rating | No Enclosure |
Horsepower @ Three Phase - 600V AC | 1 hp |
Rated Service Short-Circuit Breaking Capacity | 100% 230/240 V AC 50/60 Hz IEC 60947-2, 100% 400/415 V AC 50/60 Hz IEC 60947-2, 100% 440 V AC 50/60 Hz IEC 60947-2, 100% 500 V AC 50/60 Hz IEC 60947-2, 100% 690 V AC 50/60 Hz IEC 60947-2 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
Manual Motor Starter, Knob, 1 to 1.6A, 3P, SCHNEIDER, Mfr# GV2P06
$225,99
Free shipping will be applied on orders over $50
Manual Motor Starter, NEMA Size Not Applicable, Horsepower @ Single Phase - 240V AC 1/10 hp, Maximum Voltage Rating 600V AC, Number of Poles 3, Operator Selector Switch, Phase Three, Current AC 1.6 A, Horsepower @ Three Phase - 480V AC 3/4 hp, Series TeSys Deca, Horsepower @ Three Phase - 600V AC 1 hp, Maximum Overload Relay Current Setting 1.6 A, Minimum Overload Relay Current Setting 1 A, NEMA Enclosure Rating No Enclosure, Overload Protection Type Thermal, Starter Style IEC
9999 in stock
Must order in multiples of 1
Subtotal:
$225.99
You must be logged in to post a review.
Reviews
There are no reviews yet.