| Property | Value |
|---|---|
| Depth | 78.5 mm |
| Height | 101 mm |
| Item | Manual Starter 600Vac 14Amp Iec |
| Width | 45 mm |
| Standards | EN/IEC 60947-2 || EN/IEC 60947-4-1 |
| Breaking Capacity | 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 15 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2 || 8 kA Icu 440 V AC 50/60 Hz IEC 60947-2 || 6 kA Icu 500 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 690 V AC 50/60 Hz IEC 60947-2 |
| Color | dark grey |
| Ip Degree Of Protection | IP20 IEC 60529 |
| Fixing Mode | 35 mm symmetrical DIN rail clipped || panel screwed with adaptor plate) |
| Device Application | motor protection |
| Product Certifications | CCC || UL || CSA || EAC || ATEX || LROS (Lloyds register of shipping) || BV || RINA || DNV-GL || UKCA |
| Electrical Durability | 100000 cycles AC-3 415 V In |
| Thermal Protection Adjustment Range | 9-14 A IEC 60947-4-1 |
| Product Name | TeSys GV2 || TeSys Deca |
| Mechanical Robustness | shocks 30 Gn for 11 ms || vibrations 5 Gn, 5 to 150 Hz |
| Range | TeSys Deca |
| [Ith] Conventional Free Air Thermal Current | 14 A IEC 60947-4-1 |
| [Ue] Rated Operational Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Network Frequency | 50/60 Hz IEC 60947-4-1 |
| Phase Failure Sensitivity | yes IEC 60947-4-1 |
| Trip Unit Technology | thermal-magnetic |
| Operating Altitude | 6561.68 ft (2000 m) |
| Product Or Component Type | motor circuit breaker |
| Fire Resistance | 960ΓΒ°C IEC 60695-2-11 |
| Network Type | AC |
| Control Type | push-button |
| Device Short Name | GV2ME |
| Line Rated Current | 14 A |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-2 |
| Ambient Air Temperature For Operation | -20-60ΓΒ°C |
| Motor Power Kw | 5.5-5.5 kW 400/415 V AC 50/60 Hz || 7.5-7.5 kW 500 V AC 50/60 Hz |
| [Ics] Rated Service Short-Circuit Breaking Capacity | 100 % 230/240 V AC 50/60 Hz IEC 60947-2 || 50 % 400/415 V AC 50/60 Hz IEC 60947-2 || 50 % 440 V AC 50/60 Hz IEC 60947-2 || 75 % 500 V AC 50/60 Hz IEC 60947-2 || 75 % 690 V AC 50/60 Hz IEC 60947-2 |
| Poles Description | 3P |
| Utilisation Category | category A IEC 60947-2 || AC-3 IEC 60947-4-1 |
| Ik Degree Of Protection | IK04 |
| Mechanical Durability | 100000 cycles |
| Suitability For Isolation | yes IEC 60947-1ΓΒ§ 7-1-6 |
| Power Dissipation Per Pole | 2.5 W |
| Ambient Air Temperature For Storage | -40-80ΓΒ°C |
| [Ui] Rated Insulation Voltage | 690 V AC 50/60 Hz IEC 60947-2 |
| Rated Duty | continuous IEC 60947-4-1 |
| Climatic Withstand | IACS E10 |
| Magnetic Tripping Current | 170-170 A |
| Country of Origin (subject to change) | France |
| Package Quantity | 1 |
Manual Starter 600Vac 14Amp Iec, Schneider Electric, Mfr#: GV2ME163
$259.99
Free shipping will be applied on orders over $50
Manual Starter 600Vac 14Amp Iec
9999 in stock
Subtotal:
$259.99
You must be logged in to post a review.
Reviews
There are no reviews yet.