Item | NEMA Magnetic Motor Starter |
Overload Relay Amp Setting | 50 to 200A |
Coil Volts | 480V AC |
Enclosure NEMA Rating | No Enclosure |
Auxiliary Contact Form | 1NO |
HP @ 3 Phase - 240V | 40 hp |
Starter Type | NEMA Style |
Action | Reversing |
Amps AC | 115 |
NEMA Size | 3-1/2 |
Number of Poles | 3 |
HP @ 3 Phase - 480V | 75 hp |
Standards | CSA 22.2 No.14, NEMA ICS 2, UL 508 |
HP @ 3 Phase - 208V | 30 hp |
Depth | 5.65 in |
HP @ 3 Phase - 575V | 75 hp |
Width | 12.75 in |
Height | 11.44 in |
Hz | 50/60 |
Thermal Unit Code | Not Applicable |
Includes Auxiliary Contacts | Yes |
Maximum Operating Temperature | 104 Degrees F |
Minimum Overload Relay Current Setting | 50 A |
Overall Depth | 5.65 in |
Reversing Capability | Reversing |
Minimum Operating Temperature | -4 Degrees F |
Mounting Style | Surface |
Terminal Connection Type | Screw Terminals |
Horsepower @ Three Phase - 208V AC | 30 hp |
Maximum Voltage Rating | 600V AC |
Response Time | 10 to 24 msec (OFF-Delay Time), 19 to 29 msec (ON-Delay Time) |
Overload Protection Type | Electronic |
Number of Auxillary Contacts | 1 |
Overall Width | 12.75 in |
Overall Height | 11.44 in |
Current AC | 115 A |
Horsepower @ Three Phase - 240V AC | 40 hp |
Coil Voltage | 380-440/440-480V AC |
Starter Style | NEMA |
Phase | Three |
Horsepower @ Three Phase - 600V AC | 75 hp |
Auxiliary Contact Module Capacity | 7 |
NEMA Enclosure Rating | No Enclosure |
Mechanical Operating Durability | 10,000,000 |
Mounting Postion | Vertical |
Series | FVR |
Horsepower @ Three Phase - 480V AC | 75 hp |
Trip Class | 5/10/20/30 |
Maximum Overload Relay Current Setting | 200 A |
Frequency | 50/60 Hz |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Reversing NEMA Magnetic Motor Starter, No Enclosure NEMA Rating, 480V AC, 3 Poles, 1NO, SIEMENS, Mfr# 22IUH32AH
$3879,99
Free shipping will be applied on orders over $50
NEMA Magnetic Motor Starter, Includes Auxiliary Contacts Yes, Maximum Overload Relay Current Setting 200 A, Overload Protection Type Electronic, Minimum Overload Relay Current Setting 50 A, Trip Class 5/10/20/30, Series FVR, Number of Poles 3, Number of Auxillary Contacts 1, Phase Three, Mounting Style Surface, Auxiliary Contact Form 1NO, Starter Style NEMA, Reversing Capability Reversing, Maximum Voltage Rating 600V AC, Coil Voltage 380-440/440-480V AC, Horsepower @ Three Phase - 600V AC 75 hp
0 in stock
Must order in multiples of 1
Subtotal:
$3879.99
You must be logged in to post a review.
Reviews
There are no reviews yet.