Standards | 2004/108/EC || EN 61000-6-1 || 2006/95/EC || EN 61000-6-3 || EN 61000-6-2 || IEC 61812-1 || EN 61000-6-4 |
Item | On-delay,Timer,240V,7A |
Width | 17.5 mm |
Maximum Voltage Drop | <4 V 3-wire || <8 V 2-wire |
Marking | CE |
Voltage Range | 0.85...1.1 Us |
Minimum Switching Current | 10 mA |
Functionality | on-delay timing |
Operating Rate In Hz | 10 Hz |
Shock Resistance | 15 gn 11 ms IEC 60068-2-27 |
Supply Frequency | 50...60 Hz +/- 5 % |
On-Load Factor | 1 |
Control Type | selector switch front panel |
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25°C IEC 61812-1 |
Breaking Capacity | 0.5 A AC/DC UL || 0.7 A AC/DC 20°C |
Time Delay Range | 1...10 s || 10...100 h || 6...60 s || 0.1...1 s || 1...10 min || 6...60 min || 1...10 h |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Ambient Air Temperature For Storage | -30-60°C |
Derating Factor | 5 mA/°C |
Maximum Switching Voltage | 250 V AC/DC |
[Uimp] Rated Impulse Withstand Voltage | 5 kV 1.2/50µs |
Reset Time | 350 ms on de-energisation typical |
Time Delay Type | power on-delay, A |
Insulation Resistance | 100 MOhm 500 V DC IEC 60664-1 |
Immunity To Microbreaks | 20 ms |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1 |
Maximum Power Consumption In W | 1.5 W 240 V DC |
Electrical Durability | 100000000 cycles |
Electromagnetic Compatibility | electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022 |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Impulse Duration | 0.05 s typical |
Connections - Terminals | screw terminals, 1 x 0.5...1 x 3.3 mm? AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end |
Component Name | RE17L |
Temperature Drift | +/- 0.05 %/°C |
Power Consumption In Va | 0-3 VA 240 V AC |
Discrete Output Type | solid state |
Voltage Drift | +/- 0.2 %/V |
Product Or Component Type | single function relay |
Maximum Output Current | 20 A |
Maximum Leakage Current | 5 mA |
Ambient Air Temperature For Operation | -20-60°C |
Vibration Resistance | 20 m/s? 10-150 Hz)IEC 60068-2-6 |
Compatibility Code | RE17 |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Maximum Delay Response | 100 ms |
Relative Humidity | 93-93 % without condensation IEC 60068-2-30 |
Mounting Position | any position in relation to normal vertical mounting plane |
Product Certifications | GL || CSA || cULus |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Housing Material | self-extinguishing |
Ip Degree Of Protection | IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel) |
Nominal Output Current | 0.7 A |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Country of Origin (subject to change) | India |
Package Quantity | 1 |
On-delay, Timer, 240V, 7A, SCHNEIDER ELECTRIC, Mfr# RE17LAMW
$48,79
Free shipping will be applied on orders over $50
On-delay,Timer,240V,7A
9999 in stock
Must order in multiples of 1
Subtotal:
$48.79
You must be logged in to post a review.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Reviews
There are no reviews yet.