| Property | Value |
|---|---|
| Item | Overload Module |
| Voltage | 24V AC |
| Phase | Single |
| Thermal Setting Range (A) | 0.15 to 0.60 |
| For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
| Reset Type - Relay | Manual |
| Current Range | 0.15 to 0.60A |
| Features | Earth Fault Protection |
| Trip Class - Overload | 10 |
| Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
| Trip Class | 10 |
| Sensing Method | Electronic |
| Number of Poles | 3 |
| Maximum Operating Temperature | 158 Degrees F |
| Terminal Connection Type | Wire Leads |
| Maximum Voltage Rating | 690V AC |
| Coil Voltage | 24V AC |
| Minumum Rated Motor Current Adjustment | 0.15 A |
| Maximum Rated Motor Current Adjustment | 0.6 A |
| Compatible with Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Reset Type | Manual |
| Compatible with Series | TeSys Ultra |
| Minimum Operating Temperature | -13 Degrees F |
| Compatible Manufacturer Part Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Compatible Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| For Use with Mfr. Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| For Use With Mfr. Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
| Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out |
| Device Application | motor control || motor protection |
| [Uc] Control Circuit Voltage | 24 V AC |
| Height | 66 mm |
| Reset | manual reset |
| Product Or Component Type | advanced control unit |
| Depth | 60 mm |
| Thermal Overload Class | class 10 40-60 Hz -25-55ΓΒ°C IEC 60947-6-2 || class 10 40-60 Hz -25-55ΓΒ°C UL 508 |
| Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B |
| [Ue] Rated Operational Voltage | 690 V AC |
| Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
| Protective Treatment | TH IEC 60068 |
| Device Short Name | LUCC |
| Compatibility Code | LUCC |
| Fixing Mode | plug-in front face) |
| Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
| Function Available | protection against overload and short-circuit || manual reset || protection against phase failure and phase imbalance || earth fault protection |
| Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
| Ambient Air Temperature For Operation | -25-70ΓΒ°C |
| Load Type | single-phase motor |
| Operating Altitude | 6561.68 ft (2000 m) |
| Thermal Protection Adjustment Range | 0.15-0.6 A |
| Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
| Fire Resistance | 960ΓΒ°C parts supporting live components IEC 60695-2-12 || 650ΓΒ°C IEC 60695-2-12 |
| Range | TeSys |
| Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
| Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
| Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
| Utilisation Category | AC-43 || AC-44 || AC-41 |
| Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit |
| Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
| Product Specific Application | basic protection and advanced functions, communication |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
| Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
| Product Name | TeSys Ultra |
| Network Frequency | 40 to 60 Hz |
| Width | 45 mm |
| [Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
| Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
| Tripping Threshold | 14.2 x Ir +/- 20 % |
| Ambient Air Temperature For Storage | -40-85ΓΒ°C |
| Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
| Typical Current Consumption | 140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38 |
| Immunity To Microbreaks | 3 ms |
| Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
| Country of Origin (subject to change) | France |
| Package Quantity | 1 |
Overload Module, 0.15 to 0.60A, 3P, 24VAC, Schneider Electric, Mfr#: LUCCX6B
$180.99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 0.6 A, Minumum Rated Motor Current Adjustment 0.15 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67
9999 in stock
Subtotal:
$180.99
You must be logged in to post a review.
Reviews
There are no reviews yet.