Item - Relay | IEC Style Overload Relay |
Item | IEC Overload Relay |
Use With - Contactors and Starters | Contactor DPE09-38 |
NEMA Size | Not Applicable |
Overload Relay Current Range | 0.63 to 1.00 A |
Trip Class - Overload | 10 |
Width | 45 mm |
Number of Poles | 3 |
Frame / Series / Class / Code | Class 10, Easy TeSys DPER |
Reset Type - Relay | Manual |
Height | 66 mm |
Sensing Method | Thermal |
Depth | 70 mm |
Body Width - Relay | 1.77 in |
Standards | cUL, EN/IEC 60947-4-1, EN/IEC 60947-5-1, REACH, RoHS, UL 60947-4-1, UL 60947-5-1 |
Features | 400 Hz Power Circuit IEC 60947-4-1, 5 A Signalling Circuit, 690 V AC |
Kit Required for Retrofit Mtg. | LAD9R1 |
Body Depth - Relay | 2.76 in |
Separate Mounting | Yes, Additional Items Needed |
Overall Height - Relay | 2.6 in |
Body Height - Relay | 2.6 in |
Trip Class | 10 |
Overall Height | 2.6 in |
Network Type | DC || AC |
Product Name | Easy TeSys DPER |
[Ui] Rated Insulation Voltage | power circuit 600 V cUL || power circuit 690 V IEC 60947-4-1 |
Relay Application | overload protection |
Product Or Component Type | thermal overload relay |
Protective Treatment | TH IEC 60068 |
Vibration Resistance | 6 gn on plate IEC 60068-2-6 |
Product Compatibility | contactor DPE09-38 |
Ambient Air Temperature For Storage | -60-70°C |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
[Ue] Rated Operational Voltage | 690 V AC 0 to 400 Hz power circuit IEC 60947-4-1 |
Connections - Terminals | control circuit screw clamp terminals 2 1-2.5 mm? flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm? flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm? solid without cable end || power circuit screw clamp terminals 1 1.5-6 mm? flexible without cable end || power circuit screw clamp terminals 1 1-4 mm? flexible with cable end || power circuit screw clamp terminals 1 1-6 mm? solid without cable end |
Protection Type | BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit |
Product Certifications | cUL |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Tightening Torque | control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals |
Device Short Name | DPER |
Network Frequency | 0 to 400 Hz |
Shock Resistance | 15 gn 11 ms IEC 60068-2-7 |
Surge Withstand | 6 kV IEC 60801-5 |
Control Type | Red push-button stop || Blue push-button reset |
Ambient Air Temperature For Operation | -20-60°C without derating IEC 60947-4-1 |
Thermal Protection Adjustment Range | 0.63-1 A |
Range | Easy TeSys |
Dielectric Strength | 1.89 kV 50 Hz IEC 60947-1 |
Temperature Compensation | -20-60°C |
Permissible Current | 3 A 120 V AC-15 signalling circuit || 0.22 A 125 V DC-13 signalling circuit |
Mounting Support | separate, with specific accessories || under contactor |
Phase Failure Sensitivity | tripping current 130 % of Ir on two phase, the last one at 0 |
Tripping Threshold | 1.14 +/- 0.06 Ir IEC 60947-4-1 |
Thermal Overload Class | class 10 IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
[Ith] Conventional Free Air Thermal Current | 5 A signalling circuit |
Body Depth | 2.76 in |
Body Height | 2.6 in |
IP Rating | IP20 |
Compatible with Series | Easy TeSys |
Overload Protection Type | Thermal |
Maximum Operating Temperature | 140 Degrees F |
Reset Type | Auto, Manual |
Maximum Voltage Rating | 690V AC |
Terminal Connection Type | Screw Clamp Terminals |
Relay Style | IEC |
Body Width | 1.77 in |
Phase | Three |
Minimum Operating Temperature | -4 Degrees F |
Maximum Overload Relay Current Setting | 1 A |
Mounting Style | Separately Mounted |
Minimum Overload Relay Current Setting | 0.63 A |
Auxiliary Contact Form | 1NO/1NC |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
OverloadRelay, IEC, Thermal, Auto/Manual, SCHNEIDER ELECTRIC, Mfr# DPER05
$25,25
Free shipping will be applied on orders over $50
IEC Overload Relay, Auxiliary Contact Form 1NO/1NC, Maximum Overload Relay Current Setting 1 A, Minimum Overload Relay Current Setting 0.63 A, Trip Class 10, Maximum Voltage Rating 690V AC, NEMA Size Not Applicable, Number of Poles 3, Reset Type Auto, Manual, Mounting Style Separately Mounted, Terminal Connection Type Screw Clamp Terminals, Compatible with Series Easy TeSys, Relay Style IEC, Overload Protection Type Thermal, Phase Three
0 in stock
Must order in multiples of 1
Subtotal:
$25.25
You must be logged in to post a review.
Reviews
There are no reviews yet.