Item | IEC Overload Relay |
Item - Relay | IEC Style Overload Relay |
Use With - Contactors and Starters | Contactor DPE09-38 |
NEMA Size | Not Applicable |
Overload Relay Current Range | 16.0 to 24 A |
Width | 45 mm |
Trip Class - Overload | 10 |
Number of Poles | 3 |
Frame / Series / Class / Code | Class 10, Easy TeSys DPER |
Reset Type - Relay | Manual |
Height | 66 mm |
Sensing Method | Thermal |
Depth | 70 mm |
Kit Required for Retrofit Mtg. | LAD9R1 |
Features | 400 Hz Power Circuit IEC 60947-4-1, 5 A Signalling Circuit, 690 V AC |
Separate Mounting | Yes, Additional Items Needed |
Body Depth - Relay | 2.76 in |
Standards | cUL, EN/IEC 60947-4-1, EN/IEC 60947-5-1, REACH, RoHS, UL 60947-4-1, UL 60947-5-1 |
Overall Height - Relay | 2.6 in |
Body Height - Relay | 2.6 in |
Body Width - Relay | 1.77 in |
Trip Class | 10 |
Overall Height | 2.6 in |
Protective Treatment | TH IEC 60068 |
Phase Failure Sensitivity | tripping current 130 % of Ir on two phase, the last one at 0 |
Vibration Resistance | 6 gn on plate IEC 60068-2-6 |
Network Type | DC || AC |
Range | Easy TeSys |
Tripping Threshold | 1.14 +/- 0.06 Ir IEC 60947-4-1 |
[Ui] Rated Insulation Voltage | power circuit 600 V cUL || power circuit 690 V IEC 60947-4-1 |
Product Or Component Type | thermal overload relay |
Thermal Protection Adjustment Range | 16-24 A |
Product Certifications | cUL |
Temperature Compensation | -20-60°C |
Tightening Torque | control circuit 1.7 N.m screw clamp terminals || power circuit 2.5 N.m screw clamp terminals |
[Uimp] Rated Impulse Withstand Voltage | 6 kV |
Network Frequency | 0 to 400 Hz |
Connections - Terminals | control circuit screw clamp terminals 2 1-2.5 mm? flexible without cable end || control circuit screw clamp terminals 2 1-2.5 mm? flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm? solid without cable end || power circuit screw clamp terminals 1 2.5-10 mm? flexible without cable end || power circuit screw clamp terminals 1 1.5-6 mm? flexible with cable end || power circuit screw clamp terminals 1 2.5-10 mm? solid without cable end |
Device Short Name | DPER |
Mounting Support | separate, with specific accessories || under contactor |
Shock Resistance | 15 gn 11 ms IEC 60068-2-7 |
Permissible Current | 1.5 A 240 V AC-15 signalling circuit || 0.1 A 250 V DC-13 signalling circuit |
Surge Withstand | 6 kV IEC 60801-5 |
Ambient Air Temperature For Storage | -60-70°C |
Dielectric Strength | 1.89 kV 50 Hz IEC 60947-1 |
Product Compatibility | contactor DPE09-38 |
Ip Degree Of Protection | IP20 conforming to IEC 60529 |
Protection Type | BS fuse 5 A - control circuit || GB2 circuit breaker 5 A - control circuit || gG fuse 5 A - control circuit |
Thermal Overload Class | class 10 IEC 60947-4-1 |
Control Type | Red push-button stop || Blue push-button reset |
Ambient Air Temperature For Operation | -20-60°C without derating IEC 60947-4-1 |
[Ith] Conventional Free Air Thermal Current | 5 A signalling circuit |
Relay Application | overload protection |
Product Name | Easy TeSys DPER |
[Ue] Rated Operational Voltage | 690 V AC 0 to 400 Hz power circuit IEC 60947-4-1 |
Auxiliary Contact Composition | 1 NO + 1 NC |
Auxiliary Contact Form | 1NO/1NC |
Maximum Voltage Rating | 690V AC |
Body Width | 1.77 in |
Mounting Style | Separately Mounted |
Compatible with Series | Easy TeSys |
Terminal Connection Type | Screw Clamp Terminals |
Minimum Operating Temperature | -4 Degrees F |
Reset Type | Auto, Manual |
Maximum Operating Temperature | 140 Degrees F |
Phase | Three |
Body Height | 2.6 in |
Relay Style | IEC |
Maximum Overload Relay Current Setting | 24 A |
IP Rating | IP20 |
Overload Protection Type | Thermal |
Body Depth | 2.76 in |
Minimum Overload Relay Current Setting | 16 A |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
OverloadRelay, IEC, Thermal, Auto/Manual, SCHNEIDER ELECTRIC, Mfr# DPER22
$26,59
Free shipping will be applied on orders over $50
IEC Overload Relay, Auxiliary Contact Form 1NO/1NC, Maximum Overload Relay Current Setting 24 A, Minimum Overload Relay Current Setting 16 A, Trip Class 10, Maximum Voltage Rating 690V AC, NEMA Size Not Applicable, Number of Poles 3, Reset Type Auto, Manual, Mounting Style Separately Mounted, Terminal Connection Type Screw Clamp Terminals, Compatible with Series Easy TeSys, Relay Style IEC, Overload Protection Type Thermal, Phase Three
0 in stock
Must order in multiples of 1
Subtotal:
$26.59
You must be logged in to post a review.
Reviews
There are no reviews yet.