Ovrload Modul, 3 to 12A, Class 10, 3P, 24VAC, Schneider Electric, Mfr#: LUCC12B

$180.99

Free shipping will be applied on orders over $50

Overload Module, Maximum Rated Motor Current Adjustment 12 A, Minumum Rated Motor Current Adjustment 3 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67

9999 in stock

Subtotal:
$180.99
Final shipping and tax calculated in checkout
Brand Name: Schneider Electric
Mfr #: LUCC12B
Availability: Ships in 14 days
SKU: GRG0827294
UPC: 785901222699
Category:

Analogues

PropertyValue
ItemOverload Module
Voltage24V AC
PhaseSingle
Thermal Setting Range (A)3.00 to 12.00
For Use WithLUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12
Number of Poles3
Sensing MethodElectronic
Reset Type - RelayManual
Trip Class10
StandardsASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Current Range3.00 to 12.0A
Trip Class - Overload10
FeaturesEarth Fault Protection
Reset TypeManual
Compatible with SeriesTeSys Ultra
Minumum Rated Motor Current Adjustment3 A
Coil Voltage24V AC
Terminal Connection TypeWire Leads
Maximum Voltage Rating690V AC
Compatible with Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Maximum Operating Temperature158 Degrees F
Maximum Rated Motor Current Adjustment12 A
Minimum Operating Temperature-13 Degrees F
Compatible Manufacturer Part NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatible Manufacturer Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use with Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
For Use With Mfr. Model NumberLU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380
Compatibility CodeLUCC
Load Typesingle-phase motor
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Device Applicationmotor control || motor protection
RangeTeSys
Operating Time35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
[Uc] Control Circuit Voltage24 V AC
Protective TreatmentTH IEC 60068
Fixing Modeplug-in front face)
Typical Current Consumption140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38
Thermal Protection Adjustment Range3-12 A
Product Compatibilitypower base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B
Motor Power Kw2.2 kW 400 to 440 V AC 50/60 Hz 1 phase
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Product Specific Applicationbasic protection and advanced functions, communication
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Width45 mm
Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Heat Dissipation2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Tripping Threshold14.2 x Ir +/- 20 %
Control Circuit Voltage Limits20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out
Product NameTeSys Ultra
Height66 mm
Resetmanual reset
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Depth60 mm
Device Short NameLUCC
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Thermal Overload Classclass 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508
Network Frequency40 to 60 Hz
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Product Or Component Typeadvanced control unit
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Utilisation CategoryAC-41 || AC-43 || AC-44
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Ambient Air Temperature For Operation-25-70°C
Ambient Air Temperature For Storage-40-85°C
Immunity To Microbreaks3 ms
Non-Dissipating Shock Wave1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Operating Altitude6561.68 ft (2000 m)
[Ue] Rated Operational Voltage690 V AC
Fire Resistance960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Function Availablemanual reset || protection against overload and short-circuit || protection against phase failure and phase imbalance || earth fault protection
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Ovrload Modul
#3 to 12A
#Class 10
#24VAC
#Schneider Electric
#Mfr: LUCC12B
#Schneider Electric
#GRG0827294
#mfr:LUCC12B
#part number:LUCC12B
#pn:LUCC12B
#part code:LUCC12B
#item number:LUCC12B
#product code:LUCC12B
#manufacturer number:LUCC12B
#manufacturers part number:LUCC12B
#mfn:LUCC12B

Reviews

There are no reviews yet.

Add a review