Case Material
Plastic Case
Operating Temp. Range
-25 Degrees to 55 Degrees C
Ripple Volts Regulation
Less Than 100mV
Hold Up Time
Greater Than 10 msec @ 115 V AC, Greater Than 60 msec @ 230 V AC
Load Regulation
Less Than 1%
Status Indicator
Green LED
Protection
Overload and Short-Circuits Automatic Reset, Over Temperature Manual Reset , Overvoltage Manual Reset
Temp. Range
-25 to 55°C (without Current Derating), 55 to 70°C (with Current Derating)
Line Regulation
Less Than 0.5%
Features
Automatic Reset, It Can Be Directly Connected To Central Distribution Board, The Product Can Be Directly Mounted On The Panel
Standards
CB Scheme, CE, CSA C22.2 No 61010-1, CSA C22.2 No 61010-2-201, CSA C22.2 No 62368-1, CUL Listed, CUL Recognized, EAC, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61010-2-201, EN 62368-1, EN/IEC 61010-1, EN/IEC 61204-3, EN/IEC 62368-1, KC, NEC class 2, RCM, UL 61010-1, UL 61010-2-201, UL 62368-1
Power Factor
0.51 at 115 V AC; 0.40 at 230 V AC
Line And Load Regulation
Less than 0.5% network in line; Less than 1% network 0 to 100% load
Residual Ripple
Less than 100 mV
Turn-On Time
Less than 2 s
Network System Compatibility
TN; TT; IT
Ambient Air Temperature For Operation
-13 to 131°F (-25 to 55°C) without current derating mounting position A Less than 6561.68 ft (2000 m); 131 to 158°F (55 to 70°C) with current derating of 2.67% per°C mounting position A Less than 6561.68 ft (2000 m)
Dielectric Strength
3000 V AC input/output
Input Protection Type
Integrated fuse (not interchangeable) 3.15 A; External protection (recommended) 20 A Curve B; External protection (recommended) 20 A Curve C; External protection (recommended) 2 A Curve B; External protection (recommended) 2 A Curve C
Output Protection Type
Against overload and short-circuits automatic reset; Against over temperature manual reset; Against overvoltage manual reset
Status LED
1 LED (Green) output voltage
Supply
SELV IEC 60950-1; SELV IEC 60204-1; SELV IEC 60364-4-41
Meantime Between Failure
3000000 h at 77°F (25°C), full load; 1000000 h at 131°F (55°C), 80% load
Electromagnetic Emission
Conducted emissions IEC 61000-6-3; Radiated emissions IEC 61000-6-4
Vibration Resistance
3 mm 2 to 9 Hz)IEC 60721-3-3; 10 m/s² 9 to 200 Hz)IEC 60721-3-3
Current Consumption
Less than 0.4 A 115 V AC; Less than 0.25 A 230 V AC
Efficiency
81% 115 V AC; 81% 230 V AC
Startup With Capacitive Loads
3000 µF
Power Supply Type
Regulated switch mode
Power Supply Output Current
0.625 A
Holding Time
Greater than 10 ms 115 V AC; Greater than 60 ms 230 V AC
Power Dissipation in W
3.5 W
Electromagnetic Immunity
Immunity to electrostatic discharge - test level: 8 kV (contact discharge) conforming to IEC 61000-4-2; Immunity to electrostatic discharge - test level: 15 kV (air discharge) conforming to IEC 61000-4-2; Electromagnetic field immunity test - test level: 15 V/m (80 MHz to 2 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test - test level: 5 V/m (2 to 2.7 GHz) conforming to IEC 61000-4-3; Electromagnetic field immunity test - test level: 5 V/m (2.7 to 6 GHz) conforming to IEC 61000-4-3; Immunity to fast transients - test level: 4 kV (on input-output) conforming to IEC 61000-4-4; Surge immunity test - test level: 4 kV (between power supply and earth) conforming to IEC 61000-4-5; Surge immunity test - test level: 3 kV (between phases) conforming to IEC 61000-4-5; Immunity to conducted disturbances - test level: 15 V (0.15 to 80 MHz) conforming to IEC 61000-4-6; Immunity to magnetic fields - test level: 30 A/m (50 to 60 Hz) conforming to IEC 61000-4-8; Immunity to voltage dips - test level: 100% (1 cycle) conforming to IEC 61000-4-11; Immunity to voltage dips - test level: 60% (10 cycles) conforming to IEC 61000-4-11; Immunity to voltage dips - test level: 30% (25 cycles) conforming to IEC 61000-4-11; Disturbing field emission conforming to EN 55016-2-3; Limits for harmonic current emissions conforming to IEC 61000-3-2; conforming to EN 55016-1-2; conforming to EN 55016-2-1
Product Certifications
CE; CUL Listed; CUL Recognized; RCM; CB Scheme; EAC; KC; NEC class 2
Maximum Leakage Current
0.25 mA 240 V AC
Operating Altitude
Less than 6561.68 ft (2000 m) overvoltage category III; 2000 m to 5000 m overvoltage category II
Shock Resistance
150 m/s² 11 ms
Inrush Current
15 A 115 V; 30 A 230 V
Electrical Shock Protection Class
Class II without PE connection
Country of Origin (subject to change)
India