| Property | Value |
|---|---|
| Item | IEC Power Contactor |
| Full Load Amps-Inductive | 9 A |
| Full Load Amps-Resistive | 22 A |
| Number of Poles | 3 |
| Coil Volts | 110 V AC |
| HP @ 1 Phase - 120V | 1/3 hp |
| HP @ 1 Phase - 240V | 1 hp |
| Height | 70 mm |
| Width | 45 mm |
| HP @ 3 Phase - 208V | 2 hp |
| HP @ 3 Phase - 240V | 3 hp |
| Depth | 73 mm |
| HP @ 3 Phase - 575V | 7 1/2 hp |
| HP @ 3 Phase - 480V | 5 hp |
| Series | SIRIUS 3RT20 |
| Standards | REACH Art 33, WEEE (2012/19/EU) |
| Frame / Series / Class / Code | S00 |
| Auxiliary Contact Form | 1NC |
| Aux. Contact Configuration | 1NC |
| Hz | 50/60 |
| NEMA Size | Not Applicable |
| Rated operating power with AC-3, 400 V | 4 kilowatt |
| suitable for series installation | Yes |
| Power loss, static, current-independent [Pls] | 4.2 watt |
| Rated current [In] for the power loss specification | 9 ampere |
| Max. rated AC voltage for controls, 50 Hz | 110 volt |
| Connection type | Spring pulley connection |
| max. rated AC voltage for controls (60 Hz) | 110 volt |
| rated operational power AC-1 at 400 V | 13 kilowatt |
| Power loss per pole, current-dependent [PlIp] | 0.3 watt |
| Number of making contacts and main contacts | 3 |
| Rated operating current Ie with AC-3, 400 V | 9 ampere |
| Mounting Postion | Vertical |
| Reversing Capability | Non-Reversing |
| Embedded Surge Suppressor | No |
| Horsepower @ Single Phase - 120V AC | 1/3 hp |
| Number of Normally Open Main Contacts | 3 |
| Mounting Hole Diameter | 0.2 in |
| Contactor Style | IEC |
| Horsepower @ Three Phase - 240V AC | 3 hp |
| Frequency | 50/60 Hz |
| NEMA Enclosure Rating | No Enclosure |
| Response Time | 10 to 18 msec (AC Operation Closing Delay Operation Opening Delay Operating Times for 1.0 x Us1), 15 to 17.5 msec (DC Operation Opening Delay Operating Times For 0.8 ... 1.1 X Us1), 16 to 17.5 msec (DC Operation Opening Delay Operating Times for 1.0 x Us), 4 to 16 msec (AC Operation Opening Delay Operating Times for 0.8 ... 1.1 X Us1), 4 to 16 msec (AC Operation Opening Delay Operating Times for 1.0 x Us), 50 to 170 msec (DC Operation Closing Delay Operating Times for 0.8 ... 1.1 X Us1), 55 to 80 msec (DC Operation Closing Delay Operating Times for 1.0 x Us), 9 to 38 msec (AC Operation Closing Delay) |
| Horsepower @ Three Phase - 208V AC | 2 hp |
| Overall Height | 3.08 in |
| Number of Auxillary Contacts | 1 |
| Overall Depth | 2.92 in |
| Mounting Hole Distance - Height | 1.97 in |
| Horsepower @ Single Phase - 240V AC | 1 hp |
| Horsepower @ Three Phase - 480V AC | 5 hp |
| IP Rating | IP20 |
| Full Load Current - Inductive | 9 A |
| Terminal Connection Type | Spring Loaded Terminals |
| Overall Width | 1.97 in |
| Mechanical Operating Durability | 30,000,000 |
| Maximum Operating Temperature | 140 Degrees F |
| Maximum Voltage Rating | 690V AC |
| Frame Size | S00 |
| Phase | Three |
| Horsepower @ Three Phase - 600V AC | 7 1/2 hp |
| Minimum Operating Temperature | -13 Degrees F |
| Coil Voltage | 110V AC |
| Includes Auxiliary Contacts | Yes |
| Mounting Style | DIN Rail, Surface |
| Mounting Hole Distance - Width | 1.38 in |
| Full Load Current - Resistive | 22 A |
| Country of Origin (subject to change) | Germany |
| Package Quantity | 1 |
IECPowerContactor, Non-Reversing, 110VAC, Siemens, Mfr#: 3RT20162AF02
$78.95
Free shipping will be applied on orders over $50
IEC Power Contactor, Auxiliary Contact Form 1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 22 A, Reversing Capability Non-Reversing, Overall Height 3.08 in, Overall Width 1.97 in, Terminal Connection Type Spring Loaded Terminals, Frame Size S00, Mounting Style DIN Rail, Surface, Series SIRIUS 3RT20, Number of Auxillary Contacts 1, Contactor Style IEC
9999 in stock
Subtotal:
$78.95
You must be logged in to post a review.
Reviews
There are no reviews yet.