Item | Digital Pressure Sensor |
Range | 0 to 5800 psi |
Power Required | 18 to 30V DC |
Process Connection | 1/4 in NPT |
Electrical Connection | 4 Pin M12 Connector |
Display | Display unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit |
IP Rating | 65/67 |
Burst Pressure | 24,650 psi |
Output Current | 150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C |
Housing Material | Stainless Steel |
Temp. Range | -13 Degrees to 176 Degrees F |
Wetted Materials | Ceramic, Fluorocarbon |
Contact Form | (2) SPST |
Off Set Point | 20 to 5780 psi |
Compatible With | Air and Liquids |
On Set Point | 40 to 5800 psi |
Circuit Type | PNP/NPN |
Application | for industrial applications |
Materials | 1.4542 (17-4 PH / 630), stainless steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC |
Reverse polarity protection | yes |
Min. pressure cycles | 100 million |
EMC | DIN EN 61000-6-2 DIN EN 61000-6-3 |
Protection | IP 65, IP 67 |
Response time [ms] | < 3 |
IO-Link functions (acyclical) | application specific tag |
Set point SP | 4...400 bar 40...5800 psi 0.4...40 MPa, 3...400 bar 49...5802 psi 0.3...40 MPa |
Media | liquids and gases |
Min. difference between SP and rP | 2 bar 30 psi 0.2 MPa, 2 bar 10 psi 0.2 MPa |
Type of pressure | relative pressure |
Required master port type | A, (when pin 2 not connected: B) |
Measuring range | 0...400 bar 0...5800 psi 0...40 MPa |
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis, Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) |
IO-Link resolution pressure [bar] | 1, 0.2 |
Hysteresis deviation [% of the span] | <± 0,25 |
Special feature | Gold-plated contacts |
Parameter setting options | hysteresis / window, normally open / normally closed, switching logic, switch-on/switch-off delay, Damping, Display unit |
Connection | Connector: 1 x M12, coding: A, Contacts: gold-plated |
Min. bursting pressure | 1700 bar 24650 psi 170 MPa |
Power-on delay time [s] | 0.3 |
IO-Link resolution pressure [MPa] | 0.1, 0.02 |
Characteristics deviation [% of the span] | <± 0,25 (BFSL) / <± 0,5 (LS), (BFSL = Best Fit Straight Line, LS = limit value setting) |
Current consumption [mA] | < 35 |
IO-Link revision | 1.1 |
Min. process cycle time [ms] | 3, 2.3 |
Pressure rating | 800 bar 11580 psi 80 Mpa |
Output signal | switching signal, IO-Link, (configurable) |
Shock resistance | DIN EN 60068-2-27 50 g (11 ms) |
Integrated watchdog | yes |
SIO mode | yes |
Switch point accuracy [% of the span] | <± 0,5 |
Long-term stability [% of the span] | <± 0,05, (per 6 months) |
Vibration resistance | DIN EN 60068-2-6 20 g (10...2000 Hz) |
MTTF [years] | 214 |
In steps of | 1 bar 1 psi 0.1 MPa, 2 bar 20 psi 0.2 MPa |
Number of digital outputs | 2 |
Output function | normally open / normally closed, (parameterisable) |
Temperature coefficient span [% of the span / 10 K] | 0,2, (-25...80°C) |
Operating voltage [V] | 18...30 DC, (to SELV/PELV) |
Max. voltage drop switching output DC [V] | 2.5 |
Short-circuit protection | yes |
Permanent current rating of switching output DC [mA] | 150, (200 (...60°C) 250 (...40°C)) |
Medium temperature [°C] | -25...80 |
Temperature coefficient zero point [% of the span / 10 K] | 0,2, (-25...80°C) |
Ambient temperature [°C] | -25...80 |
IO-Link process data (cyclical) | function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2 |
Storage temperature [°C] | -40...100 |
Repeatability [% of the span] | <± 0,1, (with temperature fluctuations < 10 K) |
SDCI standard | IEC 61131-9 |
Pressure Equipment Directive | Sound engineering practice, can be used for group 2 fluids, group 1 fluids on request |
MAWP (for applications according to CRN) | 800 bar 11580 psi 80 MPa |
Restrictor element integrated | no (can be retrofitted) |
Number of inputs and outputs | Number of digital outputs: 2 |
Electrical design | PNP/NPN |
Protection class | III |
Overload protection | yes |
Transmission type | COM2 (38,4 kBaud) |
Switching frequency DC [Hz] | < 170 |
Total number of outputs | 2 |
Min. insulation resistance [M?] | 100, (500 V DC) |
Delay time programmable dS, dr [s] | 0...50 |
UL approval | UL Approval no. J003 |
Communication interface | IO-Link |
Materials (wetted parts) | 1.4542 (17-4 PH / 630) |
Reset point rP | 1...398 bar 20...5773 psi 0.1...39.8 MPa, 2...398 bar 20...5780 psi 0.2...39.8 MPa |
Type of short-circuit protection | pulsed |
Measuring element | metallic thin film cell |
Country of Origin (subject to change) | Germany |
Package Quantity | 1 |
Pressure Sensor, Range 0 to 5800 psi, IFM, Mfr# PN7270
$307.48
Free shipping will be applied on orders over $50
Digital Pressure Sensor, Power Required 18 to 30V DC, Range 0 to 5800 psi, Compatible With Air and Liquids, Circuit Type PNP/NPN, Output Current 150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C, Contact Form (2) SPST, On Set Point 40 to 5800 psi, Off Set Point 20 to 5780 psi, Burst Pressure 24,650 psi, Process Connection 1/4 in NPT, IP Rating 65/67, Housing Material Stainless Steel, Wetted Materials Ceramic, Fluorocarbon, Electrical Connection 4 Pin M12 Connector
9999 in stock
Must order in multiples of 1
Subtotal:
$307.48
You must be logged in to post a review.
Reviews
There are no reviews yet.