Discount -3%

Pressure Sensor, Range 0 to 5800 psi, IFM, Mfr# PN7270

$307.48

Free shipping will be applied on orders over $50

Digital Pressure Sensor, Power Required 18 to 30V DC, Range 0 to 5800 psi, Compatible With Air and Liquids, Circuit Type PNP/NPN, Output Current 150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C, Contact Form (2) SPST, On Set Point 40 to 5800 psi, Off Set Point 20 to 5780 psi, Burst Pressure 24,650 psi, Process Connection 1/4 in NPT, IP Rating 65/67, Housing Material Stainless Steel, Wetted Materials Ceramic, Fluorocarbon, Electrical Connection 4 Pin M12 Connector

9999 in stock

Must order in multiples of 1
Subtotal:
$307.48
Final shipping and tax calculated in checkout
Brand Name: IFM
Mfr #: PN7270
Availability: Ships in 1 days
SKU: GRG5893030 Category:
ItemDigital Pressure Sensor
Range0 to 5800 psi
Power Required18 to 30V DC
Process Connection1/4 in NPT
Electrical Connection4 Pin M12 Connector
DisplayDisplay unit 3 x LED, green (bar, psi, MPa) switching status 2 x LED, yellow measured values alphanumeric display, red/green 4-digit
IP Rating65/67
Burst Pressure24,650 psi
Output Current150mA, 200mA @ 60 Degrees C, 250mA @ 40 Degrees C
Housing MaterialStainless Steel
Temp. Range-13 Degrees to 176 Degrees F
Wetted MaterialsCeramic, Fluorocarbon
Contact Form(2) SPST
Off Set Point20 to 5780 psi
Compatible WithAir and Liquids
On Set Point40 to 5800 psi
Circuit TypePNP/NPN
Applicationfor industrial applications
Materials1.4542 (17-4 PH / 630), stainless steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC
Reverse polarity protectionyes
Min. pressure cycles100 million
EMCDIN EN 61000-6-2 DIN EN 61000-6-3
ProtectionIP 65, IP 67
Response time [ms]< 3
IO-Link functions (acyclical)application specific tag
Set point SP4...400 bar 40...5800 psi 0.4...40 MPa, 3...400 bar 49...5802 psi 0.3...40 MPa
Medialiquids and gases
Min. difference between SP and rP2 bar 30 psi 0.2 MPa, 2 bar 10 psi 0.2 MPa
Type of pressurerelative pressure
Required master port typeA, (when pin 2 not connected: B)
Measuring range0...400 bar 0...5800 psi 0...40 MPa
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis, Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
IO-Link resolution pressure [bar]1, 0.2
Hysteresis deviation [% of the span]<± 0,25
Special featureGold-plated contacts
Parameter setting optionshysteresis / window, normally open / normally closed, switching logic, switch-on/switch-off delay, Damping, Display unit
ConnectionConnector: 1 x M12, coding: A, Contacts: gold-plated
Min. bursting pressure1700 bar 24650 psi 170 MPa
Power-on delay time [s]0.3
IO-Link resolution pressure [MPa]0.1, 0.02
Characteristics deviation [% of the span]<± 0,25 (BFSL) / <± 0,5 (LS), (BFSL = Best Fit Straight Line, LS = limit value setting)
Current consumption [mA]< 35
IO-Link revision1.1
Min. process cycle time [ms]3, 2.3
Pressure rating800 bar 11580 psi 80 Mpa
Output signalswitching signal, IO-Link, (configurable)
Shock resistanceDIN EN 60068-2-27 50 g (11 ms)
Integrated watchdogyes
SIO modeyes
Switch point accuracy [% of the span]<± 0,5
Long-term stability [% of the span]<± 0,05, (per 6 months)
Vibration resistanceDIN EN 60068-2-6 20 g (10...2000 Hz)
MTTF [years]214
In steps of1 bar 1 psi 0.1 MPa, 2 bar 20 psi 0.2 MPa
Number of digital outputs2
Output functionnormally open / normally closed, (parameterisable)
Temperature coefficient span [% of the span / 10 K]0,2, (-25...80°C)
Operating voltage [V]18...30 DC, (to SELV/PELV)
Max. voltage drop switching output DC [V]2.5
Short-circuit protectionyes
Permanent current rating of switching output DC [mA]150, (200 (...60°C) 250 (...40°C))
Medium temperature [°C]-25...80
Temperature coefficient zero point [% of the span / 10 K]0,2, (-25...80°C)
Ambient temperature [°C]-25...80
IO-Link process data (cyclical)function bit length pressure 16 device status 4 binary switching information 2, function bit length pressure 14 binary switching information 2
Storage temperature [°C]-40...100
Repeatability [% of the span]<± 0,1, (with temperature fluctuations < 10 K)
SDCI standardIEC 61131-9
Pressure Equipment DirectiveSound engineering practice, can be used for group 2 fluids, group 1 fluids on request
MAWP (for applications according to CRN)800 bar 11580 psi 80 MPa
Restrictor element integratedno (can be retrofitted)
Number of inputs and outputsNumber of digital outputs: 2
Electrical designPNP/NPN
Protection classIII
Overload protectionyes
Transmission typeCOM2 (38,4 kBaud)
Switching frequency DC [Hz]< 170
Total number of outputs2
Min. insulation resistance [M?]100, (500 V DC)
Delay time programmable dS, dr [s]0...50
UL approvalUL Approval no. J003
Communication interfaceIO-Link
Materials (wetted parts)1.4542 (17-4 PH / 630)
Reset point rP1...398 bar 20...5773 psi 0.1...39.8 MPa, 2...398 bar 20...5780 psi 0.2...39.8 MPa
Type of short-circuit protectionpulsed
Measuring elementmetallic thin film cell
Country of Origin (subject to change)Germany
Package Quantity1
TAGS:
#Pressure Sensor
#Range 0 to 5800 psi
#IFM
#Mfr PN7270
#IFM
#GRG5893030
#mfr:PN7270
#part number:PN7270
#pn:PN7270
#part code:PN7270
#item number:PN7270
#product code:PN7270
#manufacturer number:PN7270
#manufacturers part number:PN7270
#mfn:PN7270

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!