Center Line Pipe Center Size
2 13/16 in
Electrical Connections
1/2
Valve Design
3-Way/2-Position
Item
Quick Exhaust Solenoid Valve
Valve Configuration
Universal
Body Material - Valves
Brass
Coefficient of Volume
0.12
Max. Operating Pressure Differential Air/Inert Gas
100 psi
NEMA Rating
3, 3S, 4, 4X, 6, 6P, 7, 9
Valve Ways and Positions
3-Way/2-Position
Max. Operating Pressure Differential Water
100 psi
Seal Material - Valves
NBR
Environmental Rating - Valves
Explosion Proof, Indoor, Outdoor
Coil Enclosure
Explosionproof and Watertight
Min. Operating Pressure Differential
0 psi
Max. Fluid Temp.
200 Degrees F
Max. Operating Pressure Differential Light Oil
100 psi
Media
Air/Inert Gas, Light Oil and Water
Operation Type
Direct Acting
Application
Analytical and Diagnostic Equipment, Dust Collector Systems, Life Sciences, Metal Stamping, Press Room
Standards
ATEX, CSA, IIECEx, UL Listed
Operating Pressure Differential - Minimum
0 psi
Operating Pressure Differential Air/Inert Gas - Minimum
0 psi
Mounting Orientation
Horizontal or Vertical
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
For Media
Air, Inert Gases, Light Oil, Water
Operating Pressure Differential Steam - Minimum
Not Applicable
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Operating Pressure Differential Light Oil - Maximum
100 psi
Operating Pressure Differential Air/Inert Gas - Maximum
100 psi
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Water - Maximum
100 psi
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Operating Pressure Differential Light Oil - Minimum
0 psi
Valve Positions
2-Position
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
NEMA Enclosure Rating
3, 3S, 4, 4X, 6, 6P, 7, 9
Coefficient of Volume (Cv)
0.12
Operating Pressure Differential Hot Water - Minimum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Operating Pressure Differential Hot Water - Maximum
Not Rated
Environmental Rating
Indoor, Outdoor
Outlet Connection Type
NPTF
Inlet Connection Type
NPTF
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Steam - Maximum
Not Rated
Valve Starting Configuration
Configurable
Fluid Temperature - Maximum
200 Degrees F
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Operating Pressure Differential Water - Minimum
0 psi
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Country of Origin (subject to change)
Mexico