Coil Volts | 600V |
Item | Relay 600V 10Amp Tesys+ Options |
Width | 45 mm |
Standards | EN/IEC 60947-5-1 || GB/T 14048.5 || UL 60947-5-1 || CSA C22.2 No 60947-5-1 || JIS C8201-5-1 |
Depth | 84 mm |
Height | 77 mm |
Product Or Component Type | control relay |
Device Short Name | CAD |
Mechanical Robustness | shocks control relay open10 Gn for 11 ms IEC 60068-2-27 || shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 || vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6 |
[Icw] Rated Short-Time Withstand Current | 100 A - 1 s || 120 A - 500 ms || 140 A - 100 ms |
Protective Treatment | TH IEC 60068 |
Hold-In Power Consumption In Va | 8-8 VA 50 Hz 20°C) |
Mechanical Durability | 30 Mcycles |
[Ue] Rated Operational Voltage | <= 690 V AC 25...400 Hz |
Ambient Air Temperature For Operation | -40-60°C || 60-70°C with derating |
Mounting Support | plate || rail |
Control Circuit Type | AC 50/60 Hz |
[Ith] Conventional Free Air Thermal Current | 10 A 60°C |
Utilisation Category | AC-14 || AC-15 || DC-13 |
Ambient Air Temperature For Storage | -60-80°C |
Non-Overlap Time | 1.5 ms on energisation between NC and NO contact || 1.5 ms on de-energisation between NC and NO contact |
Associated Fuse Rating | 10 A gG IEC 60947-5-1 |
Operating Time | 12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing |
Control Circuit Voltage Limits | 0.3...0.6 Uc -40-70°C drop-out AC 50/60 Hz || 0.8...1.1 Uc -40-60°C operational AC 50 Hz || 0.85...1.1 Uc -40-60°C operational AC 60 Hz || 1...1.1 Uc 60-70°C operational AC 50/60 Hz |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947 |
Contactor Application | control circuit |
[Ui] Rated Insulation Voltage | 600 V UL || 600 V CSA || 690 V IEC 60947-5-1 |
Minimum Switching Voltage | 17 V |
Ip Degree Of Protection | IP2X front face VDE 0106 |
Insulation Resistance | > 10 MOhm |
Product Name | TeSys CAD |
Operating Altitude | 0...9842.52 ft (0...3000 m) |
Minimum Switching Current | 5 mA |
Pole Contact Composition | 3 NO + 2 NC |
Connections - Terminals | lugs-ring terminals 8 mm) |
Range | TeSys || TeSys Deca |
Product Certifications | CB Scheme || CCC || UL || CSA || EAC || CE || UKCA |
Inrush Power In Va | 70-70 VA 50 Hz 20°C) |
Irms Rated Making Capacity | 140 A AC IEC 60947-5-1 || 250 A DC IEC 60947-5-1 |
[Uc] Control Circuit Voltage | 240 V AC 50/60 Hz |
Maximum Operating Rate | 180 cyc/mn |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Relay 600V 10Amp Tesys+ Options, SCHNEIDER ELECTRIC, Mfr# CAD326U7
$98,95
Free shipping will be applied on orders over $50
Relay 600V 10Amp Tesys+ Options
0 in stock
Must order in multiples of 1
Subtotal:
$98.95
You must be logged in to post a review.
Reviews