Item | Reset Volume Controller |
Output Capability | Less than 2 psig to Supply Pressure Less 1/2 PSI |
Setpoint Range Minimum (In. WC) | 0 to 1.6 |
Includes | Mounting Bracket |
Thermostat Required for Cooling | Direct/Reverse Acting |
Air Consumption (SCFM) | 0.019 |
Thermostat Required for Heating | Direct/Reverse Acting |
Connection Ports | Barbed Fittings for 3/8 in OD Polytubing |
Material of Construction | Noryl |
Control Type | DA/RA |
Color | Black |
Width (In.) | 3-1/2 |
Operating Temp. Limit (F) | 60 Degrees to 85 Degrees F |
Output Sensitivity (In. WC) | 2.25 PSI / 0.01 in wc |
Height (In.) | 4-45/64 |
Type | Direct Acting and Reverse Acting |
Main Air Pressure (PSIG) | 13 to 25 psig |
Reset Pressure Band | 3 to 10 psig |
Setpoint Range Maximum (In. WC) | 0.15 to 3.2 |
Depth (In.) | 6-13/32 |
Air Consumption | 25 scim |
Standards | RoHS Compliant |
Application | Cooling, Heating |
Housing Color | Black |
Signal Pressure - Maximum | 10 psig |
Maximum Air Pressure | 25 psi |
Housing Material | Noryl |
Series | 3800 |
Mounting Orientation | Horizontal, Vertical |
Output Sensitivity | 2.25 psi / 0.01 in wc |
Controller Type | Direct Acting, Reverse Acting |
Air Inlet Type | Barb |
Reset Start Point Maximum Setting | 10 psi |
Minimum Operating Temperature | 60 Degrees F |
Minimum Air Pressure | 13 psi |
Maximum Operating Temperature | 85 Degrees F |
Air Inlet Size | 3/8 in |
Maximum Setpoint Range | 0.15 to 3.2 in wg |
Output Pressure Capability | 20 psig to Supply Pressure |
Damper Action | Normally Open or Normally Closed |
Reset Start Point Factory Setting | 8 psi |
Product Type | Reset Volume Controller |
Weight | 1 lb |
Minimum Setpoint Range Minimum | 0 to 1.6 in wg |
Reset Start Point Minimum Setting | 3 psi |
Controller Action | Direct/Reverse Acting |
Country of Origin (subject to change) | Mexico |
Package Quantity | 1 |
Reset Volume Controller, Black, Direct Acting and Reverse Acting, JOHNSON CONTROLS, Mfr# P-3800-1
$232,99
Free shipping will be applied on orders over $50
Reset Volume Controller, Thermostat Required for Cooling Direct/Reverse Acting, Thermostat Required for Heating Direct/Reverse Acting, Reset Start Point Factory Setting 8 psi, Minimum Air Pressure 13 psi, Maximum Air Pressure 25 psi, Minimum Setpoint Range Minimum 0 to 1.6 in wg, Maximum Setpoint Range 0.15 to 3.2 in wg, Reset Start Point Minimum Setting 3 psi, Reset Start Point Maximum Setting 10 psi, Air Consumption 25 scim, Signal Pressure - Maximum 10 psig