Item
Safety Interlock Switch
Electrical Connection
terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
Body Material
PA (polyamide)
Head Material
PA (polyamide)
Standards
EN/IEC 60947-5-1 || CSA C22.2 No 14 || EN/IEC 60204-1 || EN/ISO 12100 || EN 1088/ISO 14119 || UL 508
Mechanical Durability
1000000 cycles
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Head Type
key operated turret head
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Contact Operation
slow-break, simultaneous
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Positive Opening
with NC contact
Contacts Type And Composition
2 NC
Minimum Actuation Speed
0.01 m/s
Insulation
double insulated
Product Or Component Type
safety switch
Ambient Air Temperature For Operation
-25-70°C
Electrical Shock Protection Class
class II EN/IEC 61140
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Maximum Operating Rate
10 cyc/mn for maximum durability
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Cable Entry
1 entry tapped Pg 11
Maximum Actuation Speed
0.5 m/s
[Ithe] Conventional Enclosed Thermal Current
10A
[Ie] Rated Operational Current
6 A 120 V, AC-15, A300 EN/IEC 60947-5-1 || 3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 || 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1
Product Certifications
CSA || UL
Actuator Forcible Withdrawal Rtc
10 N
Positive Opening Minimum Force
15 N
Ambient Air Temperature For Storage
-40-70°C
Cable Outer Diameter
7-10 mm
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Country of Origin (subject to change)
Indonesia