Item
Safety Interlock Switch
Actuator Length
Key Dependent
AC Contact Rating
3 A @ 120 V
DC Contact Rating
0.55 A @ 125 V
Solenoid Voltage
24 V AC/DC
Operating Temp. Range
-13 Degrees to 140 Degrees F
Standards
CSA C22.2 No 14, EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 12100, UL 508
Mechanical Durability
1000000 cycles
Shock Resistance
10 gn 11 ms IEC 60068-2-27
Vibration Resistance
5 gn 10-500 Hz)IEC 60068-2-6
Head Type
key operated turret head
Power Consumption In Va
10 VA
Ambient Air Temperature For Storage
-40-70°C
Minimum Actuation Speed
0.01 m/s
Contacts Type And Composition
2 NC
Positive Opening
with NC contact
Solenoid Contacts Type And Composition
1 NC slow-break)
Product Or Component Type
safety switch
Maximum Operating Rate
10 cyc/mn for maximum durability
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-5-1
Electromagnet Interlocking
locking on de-energisation and unlocking on energisation of solenoid
Short-Circuit Protection
10 A cartridge fuse gG (gl)
Maximum Actuation Speed
0.5 m/s
Ambient Air Temperature For Operation
-25-60°C
[Ie] Rated Operational Current
0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Electrical Shock Protection Class
class II EN/IEC 61140
Cable Entry
1 entry tapped Pg 11
Contact Operation
slow-break, simultaneous
[Us] Rated Supply Voltage
24 V - 20...10 %
Positive Opening Minimum Force
15 N
Product Certifications
UL || CSA
[Ithe] Conventional Enclosed Thermal Current
6A
Safety Level
can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 VEN/IEC 60947-1 || 300 VCSA C22.2 No 14
Actuator Forcible Withdrawal Rtc
500 N
Cable Outer Diameter
7-10 mm
Insulation
double insulated
Circuitry Action
Slow Action
Resistance Properties
Shock Resistant, Vibration Resistant
Operating Temperature - Minimum
-13 Degrees F
Actuating Key Type
Pivoting, Flat
Mechanical Operating Durability
1,000,000
Manufacturer Warranty Length
18 mo
Operating Temperature - Maximum
158 Degrees F
Country of Origin (subject to change)
France