| Property | Value |
|---|---|
| Item | Safety Interlock Switch |
| Height | 146-146 mm |
| Width | 98 mm |
| Depth | 44 mm |
| IP Rating | IP67 |
| Features | Solenoid Locking |
| Material | metal |
| Head Material | zamak |
| Series | XCSE |
| Standards | EN/IEC 60529, EN/IEC 60947-5-1 |
| Contact Form | 1NO/2NC |
| Electrical Connection | terminal 1 x 0.5...2 x 1.5 mmΓΒ² with or without cable end |
| Body Material | Zamak |
| Mechanical Durability | 1000000 cycles |
| Shock Resistance | 10 gn 11 ms IEC 60068-2-27 |
| Vibration Resistance | 5 gn 10-500 Hz)IEC 60068-2-6 |
| Head Type | key operated turret head |
| Overall Depth | 1.73 in |
| Overall Height | 5.75 in |
| Overall Width | 3.86 in |
| Actuator Material | Metal |
| Maximum Operating Rate | 10 cyc/mn for maximum durability |
| Power Consumption In Va | 10 VA inrush || 10 VA sealed |
| Signalling Circuit Type | AC/DC |
| Actuator Forcible Withdrawal Rtc | 2000 N |
| Supply Frequency | 50/60 Hz |
| Load Factor | 1 |
| Ambient Air Temperature For Operation | -25-40ΓΒ°C |
| [Uimp] Rated Impulse Withstand Voltage | 6 kV EN/IEC 60947-5-1 |
| [Ithe] Conventional Enclosed Thermal Current | 6A |
| [Us] Rated Supply Voltage | 24 V - 20...10 % |
| Design | rectangular |
| Protection Type | overvoltage protection signalling circuit |
| Positive Opening | with NC contact |
| Local Signalling | for guard open/guard closed and locked 2 LEDs (green or orange) |
| Short-Circuit Protection | 10 A cartridge fuse gG (gl) |
| Product Or Component Type | safety switch |
| Protective Treatment | TC |
| Supply Voltage Type | AC/DC |
| Signalling Circuit Voltage | 24/48 V 20...52 V) |
| Minimum Actuation Speed | 0.01 m/s |
| [Ui] Rated Insulation Voltage | 50 VEN/IEC 60947-1 signalling circuit |
| Maximum Actuation Speed | 0.5 m/s |
| Safety Level | can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508 |
| Contacts Type And Composition | 2 NC + 1 NO |
| Number Of Poles | 3 |
| Ambient Air Temperature For Storage | -40-70ΓΒ°C |
| Contact Operation | slow-break, break before make |
| Cable Outer Diameter | 9-12 mm |
| Signalling Circuit Consumption | 7 mA |
| Cable Entry | 2 entries tapped Pg 13.5 |
| Ip Degree Of Protection | IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1 |
| Solenoid Contacts Type And Composition | 1 NC + 1 NO slow-break, simultaneous) |
| Component Name | XCSE |
| Electrical Shock Protection Class | class I EN/IEC 61140 |
| Product Certifications | UL || CSA |
| Minimum Actuator Force For Extraction | 20 N |
| [Ie] Rated Operational Current | 0.55 A 125 V, DC-13, Q300 EN/IEC 60947-5-1 || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 || 3 A 120 V, AC-15, B300 EN/IEC 60947-5-1 || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 |
| Electromagnet Interlocking | locking on de-energisation and unlocking on energisation of solenoid |
| Country of Origin (subject to change) | Multiple |
| Package Quantity | 1 |
Safety Interlock 300Vac 5A Txcs, Telemecanique Sensors, Mfr#: XCSE7311
$677.99
Free shipping will be applied on orders over $50
Safety Interlock Switch, Contact Form 1NO/2NC, Series XCSE, IP Rating IP67, Body Material Zamak, Standards EN/IEC 60529, EN/IEC 60947-5-1
9999 in stock
Subtotal:
$677.99
You must be logged in to post a review.
Reviews