Item | Screw Cla Base 12A Without Terminations |
Coil Volts | 24V AC/DC, 48 to 72V AC/DC, 110 to 240V AC, 110 to 220V DC |
Auxiliary Contact Form | Linked contacts (1 NO + 1 NC) IEC 60947-4-1, Mirror contact (1 NC) IEC 60947-1 |
Starter Type | Non Reversing |
Number of Poles | 3 |
Height | 154 mm |
Features | Free of Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration, Suitability For Isolation |
Hz | 50/60 Hz |
Width | 45 mm |
Standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine |
Depth | 126 mm |
Weight | 0.865 kg |
Operating Voltage | 690V AC |
Tightening Torque | Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm), Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) Philips No 2 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) pozidriv No 2 0.24 in (6 mm) |
Maximum Operating Rate | 3600 cyc/h |
Suitability For Isolation | Yes |
Conventional Free Air Thermal Current | 12 A |
Product Or Component Type | Non reversing power base |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Device Application | Motor control, Motor protection |
Rated Service Breaking Capacity | 50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V |
Heat Dissipation | 2 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W control circuit with LUCM |
Compatibility Code | LUB |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
IP Degree Of Protection | IP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone) |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Vibration Resistance | 2 gn 5 to 300 Hz) power poles open IEC 60068-2-27, 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27 |
Rated Operational Current | 12 A Less than or Equal to 440 V, 12 A 500 V, 9 A 690 V |
Operating Altitude | 6561.68 ft (2000 m) |
Product Name | TeSys Ultra |
Mechanical Durability | 15 Mcycles |
Connections - Terminals | Power circuit screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) rigid, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) rigid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) flexible without cable end, Control circuit without connection |
Ambient Air Temperature For Operation | -13 to 140°F (-25 to 60°C) with LUCM, -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD |
Rated Insulation Voltage | 690 V IEC 60947-6-2 3, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Network Frequency | 40 to 60 Hz |
Immunity To Microbreaks | 3 ms control circuit |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Fixing Mode | Clipped DIN rail, Screw-fixed plate) |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Operating Time | 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms Greater than or Equal to 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit |
Typical Current Consumption | 130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 150 mA 24 V DC I maximum while closing with LUCM, 280 mA 110 to 220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 110 to 240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48 to 72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48 to 72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 35 mA 110 to 220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 110 to 240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48 to 72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48 to 72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V DC I rms sealed with LUCM |
Auxiliary Contacts Type | Linked contacts 1 NO + 1 NC) IEC 60947-4-1, Mirror contact 1 NC) IEC 60947-1 |
Rated Operational Voltage | 690 V AC power circuit |
Control Circuit Voltage | 24 V AC 50/60 Hz, 24 V DC, 48 to 72 V AC 50/60 Hz, 48 to 72 V DC, 110 to 240 V AC 50/60 Hz, 110 to 220 V DC |
Auxiliary Contact Composition | 1 NO + 1 NC |
Rated Impulse Withstand Voltage | 6 kVIEC 60947-6-2 |
Non-Dissipating Shock Wave | 1 kV serial mode 24 to 240 V AC IEC 60947-6-2, 1 kV serial mode 48 to 220 V DC IEC 60947-6-2, 2 kV common mode 24 to 240 V AC IEC 60947-6-2, 2 kV common mode 48 to 220 V DC IEC 60947-6-2 |
Poles Description | 3P |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Utilisation Category | AC-43, AC-44, AC-41 |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Protective Treatment | TH IEC 60068 |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Screw Cla Base 12A Without Terminations, 24V AC/DC; 48 to 72V AC/DC; 110 to 240V AC; 110 to 220V DC, SCHNEIDER ELECTRIC, Mfr# LUB120
$274,99
Free shipping will be applied on orders over $50
Screw Cla Base 12A Without Terminations
0 in stock
Must order in multiples of 1
Subtotal:
$274.99
You must be logged in to post a review.