Brand Name: SCHNEIDER ELECTRIC
Mfr #: LUB120
Availability: Ships in 5 days
SKU: GRG0561858 Category:
ItemScrew Cla Base 12A Without Terminations
Coil Volts24V AC/DC, 48 to 72V AC/DC, 110 to 240V AC, 110 to 220V DC
Auxiliary Contact FormLinked contacts (1 NO + 1 NC) IEC 60947-4-1, Mirror contact (1 NC) IEC 60947-1
Starter TypeNon Reversing
Number of Poles3
Height154 mm
FeaturesFree of Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration, Suitability For Isolation
Hz50/60 Hz
Width45 mm
StandardsEN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine
Depth126 mm
Weight0.865 kg
Operating Voltage690V AC
Tightening TorqueControl circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) flat 0.20 in (5 mm), Control circuit 7.08 to 10.62 lbf.in (0.8 to 1.2 N.m) Philips no 1 0.20 in (5 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) flat 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) Philips No 2 0.24 in (6 mm), Power circuit 16.82 to 22.13 lbf.in (1.9 to 2.5 N.m) pozidriv No 2 0.24 in (6 mm)
Maximum Operating Rate3600 cyc/h
Suitability For IsolationYes
Conventional Free Air Thermal Current12 A
Product Or Component TypeNon reversing power base
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 appendix N, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 appendix N
Product CertificationsCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Device ApplicationMotor control, Motor protection
Rated Service Breaking Capacity50 kA 230 V, 50 kA 440 V, 10 kA 500 V, 4 kA 690 V
Heat Dissipation2 W control circuit with LUCA, LUCB, LUCC, LUCD, 1.7 W control circuit with LUCM
Compatibility CodeLUB
Ambient Air Temperature For Storage-40 to 185°F (-40 to 85°C)
IP Degree Of ProtectionIP20 IEC 60947-1 front panel and wired terminals), IP20 IEC 60947-1 other faces), IP40 IEC 60947-1 front panel outside connection zone)
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Vibration Resistance2 gn 5 to 300 Hz) power poles open IEC 60068-2-27, 4 gn 5 to 300 Hz) power poles closed IEC 60068-2-27
Rated Operational Current12 A Less than or Equal to 440 V, 12 A 500 V, 9 A 690 V
Operating Altitude6561.68 ft (2000 m)
Product NameTeSys Ultra
Mechanical Durability15 Mcycles
Connections - TerminalsPower circuit screw clamp terminals 1 0.00 to 0.02 in? (1 to 10 mm?) rigid, Power circuit screw clamp terminals 1 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) flexible without cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) flexible with cable end, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1 to 6 mm?) rigid, Power circuit screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 6 mm?) flexible without cable end, Control circuit without connection
Ambient Air Temperature For Operation-13 to 140°F (-25 to 60°C) with LUCM, -13 to 158°F (-25 to 70°C) with LUCA, LUCB, LUCC, LUCD
Rated Insulation Voltage690 V IEC 60947-6-2 3, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Network Frequency40 to 60 Hz
Immunity To Microbreaks3 ms control circuit
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Fixing ModeClipped DIN rail, Screw-fixed plate)
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Operating Time35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit, 50 ms Greater than or Equal to 72 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 60 ms 48 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 70 ms 24 V closing with LUCA, LUCB, LUCC, LUCD control circuit, 75 ms closing with LUCM control circuit
Typical Current Consumption130 mA 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 140 mA 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 150 mA 24 V DC I maximum while closing with LUCM, 280 mA 110 to 220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 110 to 240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48 to 72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 280 mA 48 to 72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD, 35 mA 110 to 220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 110 to 240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48 to 72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 35 mA 48 to 72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 60 mA 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD, 70 mA 24 V DC I rms sealed with LUCM
Auxiliary Contacts TypeLinked contacts 1 NO + 1 NC) IEC 60947-4-1, Mirror contact 1 NC) IEC 60947-1
Rated Operational Voltage690 V AC power circuit
Control Circuit Voltage24 V AC 50/60 Hz, 24 V DC, 48 to 72 V AC 50/60 Hz, 48 to 72 V DC, 110 to 240 V AC 50/60 Hz, 110 to 220 V DC
Auxiliary Contact Composition1 NO + 1 NC
Rated Impulse Withstand Voltage6 kVIEC 60947-6-2
Non-Dissipating Shock Wave1 kV serial mode 24 to 240 V AC IEC 60947-6-2, 1 kV serial mode 48 to 220 V DC IEC 60947-6-2, 2 kV common mode 24 to 240 V AC IEC 60947-6-2, 2 kV common mode 48 to 220 V DC IEC 60947-6-2
Poles Description3P
Resistance To Radiated Fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
Utilisation CategoryAC-43, AC-44, AC-41
Fire Resistance1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12
Protective TreatmentTH IEC 60068
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Immunity To Voltage Dips70% / 500 ms IEC 61000-4-11
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Screw Cla Base 12A Without Terminations
#24V AC/DC; 48 to 72V AC/DC; 110 to 240V AC; 110 to 220V DC
#SCHNEIDER ELECTRIC
#Mfr LUB120
#SCHNEIDER ELECTRIC
#GRG0561858
#mfr:LUB120
#part number:LUB120
#pn:LUB120
#part code:LUB120
#item number:LUB120
#product code:LUB120
#manufacturer number:LUB120
#manufacturers part number:LUB120
#mfn:LUB120

Reviews

There are no reviews yet.

Add a review