Center Line Pipe Center Size
2 13/16 in
Electrical Connections
1/2
Valve Design
2-Way/2-Position
Valve Configuration
Normally Closed
Body Material - Valves
Brass
Min. Operating Pressure Differential
5 psi
Max. Fluid Temp.
180 Degrees F
Environmental Rating - Valves
Indoor, Outdoor
Media
Air/Inert Gas, Light Oil and Water
Valve Ways and Positions
2-Way/2-Position
Application
Air Compressors, Car Wash, Industrial Water Control, Laundry Equipment, Pumps
Max. Operating Pressure Differential Water
150 psi
Max. Operating Pressure Differential Light Oil
135 psi
Max. Operating Pressure Differential Air/Inert Gas
200 psi
NEMA Rating
1, 2, 3, 3S, 4, 4X
Seal Material - Valves
FKM
Coil Enclosure
Watertight No Junction Box
Operation Type
Pilot Operated
For Media
Air, Inert Gases, Light Oil, Water
Fluid Temperature - Maximum
180 Degrees F
Operating Pressure Differential - Minimum
5 psi
Operating Pressure Differential Water - Minimum
5 psi
Operating Pressure Differential Fuel Oil - Maximum
Not Applicable
Environmental Rating
Indoor, Outdoor
Mounting Orientation
Vertical
Operating Pressure Differential Cryogenic Fluid - Minimum
Not Applicable
Operating Pressure Differential Light Oil - Maximum
135 psi
Operating Pressure Differential Fuel Oil - Minimum
Not Applicable
Operating Pressure Differential Cryogenic Fluid - Maximum
Not Applicable
Operating Pressure Differential Hot Water - Minimum
Not Applicable
Operating Pressure Differential Steam - Maximum
Not Rated
Outlet Connection Type
NPTF
Operating Pressure Differential Fuel Gas - Minimum
Not Applicable
Operating Pressure Differential Light Oil - Minimum
5 psi
Coefficient of Volume (Cv)
4
Operating Pressure Differential Natural Gas - Maximum
Not Applicable
Inlet Connection Type
NPTF
Operating Pressure Differential Water - Maximum
150 psi
Operating Pressure Differential Liquid CO2 - Maximum
Not Applicable
Operating Pressure Differential Steam - Minimum
Not Applicable
NEMA Enclosure Rating
1, 2, 3, 3S, 4, 4X
Operating Pressure Differential Air/Inert Gas - Minimum
5 psi
Operating Pressure Differential - Maximum
200 psi
Ambient Temperature - Minimum
14 Degrees F
Operating Pressure Differential Fuel Gas - Maximum
Not Applicable
Operating Pressure Differential Hot Water - Maximum
Not Rated
Ambient Temperature - Maximum
140 Degrees F
Valve Starting Configuration
Normally Closed
Operating Pressure Differential Air/Inert Gas - Maximum
200 psi
Operating Pressure Differential Liquid CO2 - Minimum
Not Applicable
Operating Pressure Differential Natural Gas - Minimum
Not Applicable
Valve Positions
2-Position
Country of Origin (subject to change)
Mexico