Item | Overload Module |
Overload Relay Amp Setting | 0.35 to 1.4 A |
Coil Volts | 24V DC |
Height | 66 mm |
Standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine |
Features | Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset, Earth fault protection, Free of Halogen, Mercury & Pvc Free, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration |
Depth | 60 mm |
Hz | 40 to 60 Hz |
Width | 45 mm |
Operating Voltage | 690V AC |
Weight | 0.135 kg |
Compatible with Series | TeSys Ultra |
Minumum Rated Motor Current Adjustment | 0.35 A |
Maximum Voltage Rating | 690V AC |
Maximum Rated Motor Current Adjustment | 1.4 A |
Reset Type | Manual |
Phase | Three |
Trip Class | 10 |
Coil Voltage | 24V DC |
Motor Power KW | 0.25 kW 400 to 440 V AC 50/60 Hz |
Operating Time | 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit |
Operating Altitude | 6561.68 ft (2000 m) |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1 |
Device Application | Motor control, Motor protection |
Compatibility Code | LUCA |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Immunity To Microbreaks | 3 ms |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Product Or Component Type | Standard control unit |
Vibration Resistance | 2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6 |
Typical Current Consumption | 130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38 |
Main Function Available | Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset, Earth fault protection |
Load Type | 3-phase motor self-cooled |
Product Compatibility | Power base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL |
Ambient Air Temperature For Operation | -13 to 158°F (-25 to 70°C) |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Heat Dissipation | 2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38 |
Thermal Overload Class | Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508 |
Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Tripping Threshold | 14.2 x Ir +/- 20% |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
Protective Treatment | TH IEC 60068 |
Utilisation Category | AC-44, AC-43, AC-41 |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
Control Circuit Voltage | 24 V DC |
Product Specific Application | Basic protection requirements for motor starters: overload and short-circuit |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Phase Failure Sensitivity | Yes |
Rated Insulation Voltage | 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Rated Operational Voltage | 690 V AC |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Fixing Mode | Plug-in front face) |
Control Circuit Voltage Limits | 20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Std Ctrl Unit CL 10 3-PH 0.3-1.4A 24VDC, SCHNEIDER ELECTRIC, Mfr# LUCA1XBL
$123,99
-3% / ea
with subscription
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 1.4 A, Minumum Rated Motor Current Adjustment 0.35 A, Coil Voltage 24V DC, Compatible with Series TeSys Ultra, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual
9999 in stock
Must order in multiples of 1
Subtotal:
$123.99
You must be logged in to post a review.
Reviews
There are no reviews yet.