Item | Stdcntrlunitcl103Ph 01506A 24Vac |
Overload Relay Amp Setting | 0.15 to 0.6 A |
Coil Volts | 24V DC |
Features | Earth fault protection, Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset, Free of Halogen, Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock Resistance, Vibration Resistance |
Height | 66 mm |
Hz | 40 to 60 Hz |
Width | 45 mm |
Depth | 60 mm |
Standards | EN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine |
Operating Voltage | 690V AC |
Weight | 0.135 kg |
Motor Power KW | 0.09 kW 400 to 440 V AC 50/60 Hz |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Device Application | Motor control, Motor protection |
Rated Operational Voltage | 690 V AC |
Shock Resistance | 10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27 |
Fixing Mode | Plug-in front face) |
Compatibility Code | LUCA |
Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Protective Treatment | TH IEC 60068 |
Rated Insulation Voltage | 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Main Function Available | Earth fault protection, Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset |
Product Compatibility | Power base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL |
IP Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1 |
Fire Resistance | 1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Vibration Resistance | 2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6 |
Resistance To Radiated Fields | 9.14 V/m (10 V/m) 3 IEC 61000-4-3 |
Product Specific Application | Basic protection requirements for motor starters: overload and short-circuit |
Typical Current Consumption | 130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38 |
Load Type | 3-phase motor self-cooled |
Phase Failure Sensitivity | Yes |
Heat Dissipation | 2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38 |
Operating Time | 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit |
Thermal Overload Class | Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508 |
Utilisation Category | AC-43, AC-44, AC-41 |
Immunity To Microbreaks | 3 ms |
Ambient Air Temperature For Storage | -40 to 185°F (-40 to 85°C) |
Product Certifications | CE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2 |
Ambient Air Temperature For Operation | -13 to 158°F (-25 to 70°C) |
Tripping Threshold | 14.2 x Ir +/- 20% |
Operating Altitude | 6561.68 ft (2000 m) |
Control Circuit Voltage | 24 V DC |
Product Or Component Type | Standard control unit |
Control Circuit Voltage Limits | 20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out |
Immunity To Voltage Dips | 70% / 500 ms IEC 61000-4-11 |
Product Name | TeSys Ultra |
Country of Origin (subject to change) | France |
Package Quantity | 1 |