ItemStdcntrlunitcl103Ph 01506A 24Vac
Overload Relay Amp Setting0.15 to 0.6 A
Coil Volts24V DC
FeaturesEarth fault protection, Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset, Free of Halogen, Mercury & Pvc, Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock Resistance, Vibration Resistance
Height66 mm
Hz40 to 60 Hz
Width45 mm
Depth60 mm
StandardsEN 60947-6-2, IEC 60947-6-2, UL 60947-4-1, with phase barrier, CSA C22.2 No 60947-4-1, with phase barrier, CE, CCC, EAC, ASEFA, ATEX, Marine
Operating Voltage690V AC
Weight0.135 kg
Motor Power KW0.09 kW 400 to 440 V AC 50/60 Hz
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Device ApplicationMotor control, Motor protection
Rated Operational Voltage690 V AC
Shock Resistance10 gn power poles open IEC 60068-2-27, 15 gn power poles closed IEC 60068-2-27
Fixing ModePlug-in front face)
Compatibility CodeLUCA
Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Protective TreatmentTH IEC 60068
Rated Insulation Voltage690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1
Main Function AvailableEarth fault protection, Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual reset
Product CompatibilityPower base LUB12, Power base LUB32, Power base LUB38, Power base LUB120, Power base LUB320, Power base LUB380, Reversing contactor breaker LU2B12BL, Reversing contactor breaker LU2B32BL, Reversing contactor breaker LU2B38BL
IP Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1, IP20 other faces IEC 60947-1, IP40 front panel outside connection zone IEC 60947-1
Fire Resistance1760°F (960°C) parts supporting live components IEC 60695-2-12, 1202°F (650°C) IEC 60695-2-12
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4, 4 kV 4 all circuits except for serial link IEC 61000-4-4
Vibration Resistance2 gn 5 to 300 Hz power poles open IEC 60068-2-6, 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Resistance To Radiated Fields9.14 V/m (10 V/m) 3 IEC 61000-4-3
Product Specific ApplicationBasic protection requirements for motor starters: overload and short-circuit
Typical Current Consumption130 mA 24 V DC I maximum while closing with LUB12, 220 mA 24 V DC I maximum while closing with LUB32, 220 mA 24 V DC I maximum while closing with LUB38, 60 mA 24 V DC I rms sealed with LUB12, 80 mA 24 V DC I rms sealed with LUB32, 80 mA 24 V DC I rms sealed with LUB38
Load Type3-phase motor self-cooled
Phase Failure SensitivityYes
Heat Dissipation2 W control circuit with LUB12, 3 W control circuit with LUB32, 3 W control circuit with LUB38
Operating Time35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 35 ms opening with LUB38 control circuit, 70 ms closing with LUB12 control circuit, 70 ms closing with LUB32 control circuit, 70 ms closing with LUB38 control circuit
Thermal Overload ClassClass 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2, Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Utilisation CategoryAC-43, AC-44, AC-41
Immunity To Microbreaks3 ms
Ambient Air Temperature For Storage-40 to 185°F (-40 to 85°C)
Product CertificationsCE, UL, CSA, CCC, EAC, ASEFA, ATEX, Marine
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2, 8 kV 4 on contact IEC 61000-4-2
Ambient Air Temperature For Operation-13 to 158°F (-25 to 70°C)
Tripping Threshold14.2 x Ir +/- 20%
Operating Altitude6561.68 ft (2000 m)
Control Circuit Voltage24 V DC
Product Or Component TypeStandard control unit
Control Circuit Voltage Limits20 to 27 V DC 24 V in operation, 14.5 V DC 24 V drop-out
Immunity To Voltage Dips70% / 500 ms IEC 61000-4-11
Product NameTeSys Ultra
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Stdcntrlunitcl103Ph 01506A 24Vac
#SCHNEIDER ELECTRIC
#Mfr LUCAX6BL
#SCHNEIDER ELECTRIC
#GRG0852656
#mfr:LUCAX6BL
#part number:LUCAX6BL
#pn:LUCAX6BL
#part code:LUCAX6BL
#item number:LUCAX6BL
#product code:LUCAX6BL
#manufacturer number:LUCAX6BL
#manufacturers part number:LUCAX6BL
#mfn:LUCAX6BL

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!