Promotion Restriction
Not eligible for promotion
Current Measurement Range
0 to 24mADC
Item
Handheld Temperature Calibrator
Voltage Measurement Range
-10mV to 75mV DC
Accuracy
Dependent on Thermocouple Type
Thermocouple Type
J, K, T, C, E, N, R and S
Source Voltage
-10mV to 75mV DC
Measurement Functions
Current, Temperature, Voltage
Thermocouple Temperature Range
-250 Degrees to 2300 Degrees C (Dependent on Thermocouple Type)
Powered By
(4) AA Alkaline Batteries
Manufacturers Warranty Length
3 yr
Calibration Certificate
NIST Traceable
Agency Compliance
CE, CSA, TUV, RCM
Includes
Alligator Clips, Batteries, Magnetic Hanging Tool, Manual, Quick Reference Guide, Test Leads
Sensor Temperature Range
-20 Degrees to 1,750 Degrees C (Type R), -20 Degrees to 1,750 Degrees C (Type S), -200 Degrees to 1,200 Degrees C (Type U), -200 Degrees to 1,370 Degrees C (Type K), -200 Degrees to 400 Degrees C (Type T), -200 Degrees to 600 Degrees C (Type U), -200 Degrees to 900 Degrees C (Type L), -200 Degrees to 950 Degrees C (Type E), 600 Degrees to 1,800 Degrees C (Type B)
RTD Temperature Range F
-328 Degrees to 1,472 Degrees F
Accuracy - Source
0.015% +10 uA
Accuracy - Measure
0.010% +2 uA
Sensor Maximum Temperature C
Type B 1.800 Degrees C, 950 Degrees C (Type E), 1,370 Degrees C (Type K), 900 Degrees C (Type L), 1,750 Degrees C (Type R), 1,750 Degrees C (Type S), 400 Degrees C (Type T), 1,200 Degrees C (Type U), 600 Degrees C (Type U)
RTD Temperature Range C
-200 Degrees to 800 Degrees C
Includes NIST-Traceable Certificate
Yes
Thermocouple Temperature Range C
-250 Degrees to 2,300 Degrees C
Calibration Details
+/-0.002% of Reading +0.002% of Range / Degrees C ( 28 Degrees C)
Manufacturer Warranty Length
3 yr
Resistance Range
0 to 3,200 ohm
Temperature Range
-328 Degrees to 1,472 Degrees F/-200 Degrees to 800 Degrees C
Sensor Minimum Temperature C
600 Degrees C (Type B), -200 Degrees C (Type E), -200 Degrees C (Type K), -200 Degrees C (Type L), -20 Degrees C (Type R), -20 Degrees C (Type S), -200 Degrees C (Type T), -200 Degrees C (Type U)
Millivolt Accuracy
0.025% +1 Count
Millivolt Range
-10 to 75mV
For RTD Type
Ni 120, Pt 100 (385), Pt 100 (392) (3926), Pt 100 JIS (3916), Pt 1000 (385), Pt 200 (385), Pt 500 (385)
For Thermocouple Type
Type B, Type E, Type J, Type K: Type T, Type L, Type R, Type S, Type U
Sensor Minimum Temperature °C
600 Degrees C (Type B), -200 Degrees C (Type E), -200 Degrees C (Type K), -200 Degrees C (Type L), -20 Degrees C (Type R), -20 Degrees C (Type S), -200 Degrees C (Type T), -200 Degrees C (Type U)
Sensor Maximum Temperature °C
Type B 1.800 Degrees C, 950 Degrees C (Type E), 1,370 Degrees C (Type K), 900 Degrees C (Type L), 1,750 Degrees C (Type R), 1,750 Degrees C (Type S), 400 Degrees C (Type T), 1,200 Degrees C (Type U), 600 Degrees C (Type U)
Sensor Maximum Temperature °C
Type B 1.800 Degrees C, 950 Degrees C (Type E), 1,370 Degrees C (Type K), 900 Degrees C (Type L), 1,750 Degrees C (Type R), 1,750 Degrees C (Type S), 400 Degrees C (Type T), 1,200 Degrees C (Type U), 600 Degrees C (Type U)
Sensor Minimum Temperature °C
600 Degrees C (Type B), -200 Degrees C (Type E), -200 Degrees C (Type K), -200 Degrees C (Type L), -20 Degrees C (Type R), -20 Degrees C (Type S), -200 Degrees C (Type T), -200 Degrees C (Type U)
Country of Origin (subject to change)