Promotion Restriction | Not eligible for promotion |
Item | Thermometer Calibrator |
Temp. Range | 35 Degrees to 250 Degrees C |
Power Source | Loop Power |
Width | 9 1/2 in |
Height | 15 in |
Depth | 15 45/64 in |
Includes | Mains Power Cord, USB Cable, Probe Access Cover, Transport Tank Cover, Printed Safety Information, Product CD, Report of Calibration with Label, Clamp-On Ferrite (-P Models), Din Connector (-P Models), Test Lead Kit, P Models, Proc Electricity |
Interface | RS-232 |
RTD Type | PT-100, JIS |
Thermocouple Temperature Range | -25 Degrees to 250 Degrees C |
Temp. Stability | +/-0.015 Degrees C |
Well Depth | 6-7/64 in |
Accuracy | +/-0.1 Degrees C |
Display | LCD |
Agency Compliance | EN 61010-1 (2010), Category II, Degree 2, IEC 61326-1, Basic, RoHS, SCPI |
Temp. Accuracy | +/-0.1 Degrees C |
Removable Inserts | No |
Loop Supply Voltage | 24V DC |
Max. Loop Current | 4 to 20mA |
Power Required | 115V AC ( +/-10%), 50/60 Hz |
Calibration Certificate | NVLAP accredited |
Thermocouple Type | mV, E |
RTD Temperature Range | -25 Degrees to 140 Degrees C |
Temperature Range | -25 Degrees to 250 Degrees C |
Overall Depth | 15.4 in |
Typical Heating Time | 25 min (35 Degrees to 100 Degrees C), 45 min (100 Degrees to 250 Degrees C) |
Typical Settling Time | 15 min |
With Process Connections | Yes |
Handle Type | (1) Non-Rotating Bail Handle, (2) Recessed Bottom Handles |
Typical Cooling Time | 35 min (250 Degrees to 100 Degrees C), 55 min (100 Degrees to 35 Degrees C) |
Tank Size | 4 13/32 in Dia x 6 7/64 in D, 3 in Working Dia |
Tank Opening | 4.4 in |
Calibrator Weight | 35 lb |
Loop Power Characteristics | +/-6V Accuracy / 24V DC Range |
Power Source Details | 24V DC |
Resistance Sensing Current Characteristics | 8% at 1 mA |
Common Fluid Compatibility | Silicone Oil Type 200.50 |
Reference Input Resistance Characteristics | 0.0025 ohms Accuracy (0 to 42 ohms), 0.006 % Accuracy (42 to 400 ohms) |
Brand and Series | Fluke 6109A |
3-Wire Device Resistance Characteristics | 0.12 ohms Accuracy/0 to 400 ohms Range |
Reference Junction Temperature Characteristics | 0.35 Degrees C Accuracy at 0 Degrees to 40 Degrees C |
Typical Uniformity | 0.03 Degrees C up to 200 Degrees C, 0.04 Degrees C above 200 Degrees C |
Overall Dimensions | 15 in H x 9 1/2 in W x 15 13/32 in D |
RTD Temperature Range C | -25 Degrees to 140 Degrees C |
4-Wire Device Resistance Characteristics | 0.0025 ohms Accuracy/0 to 31 ohms Range, 0.008% Accuracy/31 to 400 ohms Range |
Calibrator Construction | Stainless Steel Case with Synthetic Keypad |
Thermocouple mV Characteristics | 0.025% + 0.01 mV at -10 to 100 mV |
Calibrator Type | Portable Calibration Baths |
Reference Input Temperature Characteristics | 0.007% + 0.015 Degrees C Accuracy at -25 Degrees to 250 Degrees C |
Standards | FDA, ISO |
Working Area | 3 in x 3 in |
Stability | 0.015 Degrees C |
Overall Width | 9.5 in |
Thermocouple Temperature Accuracy Characteristics | Type C: 0.84 Degrees C at 0 Degrees to 250 Degrees C, Type D: 1.12 Degrees C at 0 Degrees to 250 Degrees C, Type E: 0.44 Degrees C at -25 Degrees to 250 Degrees C, Type G/W: 3.34 Degrees C at 0 Degrees to 250 Degrees C, Type J: 0.44 Degrees C at -25 Degrees to 250 Degrees C, Type K: 0.49 Degrees C at -25 Degrees to 250 Degrees C, Type L: 0.42 Degrees C at -25 Degrees to 250 Degrees C, Type M: 0.48 Degrees C at -25 Degrees to 250 Degrees C, Type N: 0.57 Degrees C at -25 Degrees to 250 Degrees C, Type R: 1.92 Degrees C at 0 Degrees to 250 Degrees C, Type S: 1.88 Degrees C at 0 Degrees to 250 Degrees C, Type T: 0.53 Degrees C at -25 Degrees to 250 Degrees C, Type U: 0.48 Degrees C at -25 Degrees to 250 Degrees C |
Overall Height | 15 in |
Display Resolution | 0.001 Degrees , 0.01 Degrees |
Voltage | 24 V DC |
Calibrator Application | Autoclave Sterilization, Chemical Reactors, Food Processing, Food Storage Freezers, Pharmaceutical Bioreactors, Steam-in-Place Processes |
Current mA Characteristics | 0.02 % + 0.002 mA Accuracy/0 to 22 mA Range |
Tank Depth | 6.1 in |
Repeatability | 0.04 Degrees C |
Fluid Volume | 2.5 L |
Thermocouple Temperature Range C | -25 Degrees to 250 Degrees C |
Calibration Details | Traceable NVLAP-Accredited Calibration |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
Thermometer Calibrator, 24VDC, 15" H, FLUKE, Mfr# 6109A-P-156
$12880,00
Free shipping will be applied on orders over $50
Thermometer Calibrator, Fluke 6109A, Portable Calibration Baths, -25 Degrees to 250 Degrees C, 15 in H x 9 1/2 in W x 15 13/32 in D, Stainless Steel Case with Synthetic Keypad, Fluid Volume 2.5 L, Tank Size 4 13/32 in Dia x 6 7/64 in D, 3 in Working Dia
Out of stock
You must be logged in to post a review.
Reviews