Standards | EN/IEC 60601-1 || 89/336/EEC || EN/IEC 61812-1 || EN/IEC 60601-2 || 73/23/EEC || 93/68/EEC || EN 61000-6-2 || EN 50081-2 |
Item | Timer,250VAC 3A,Rexl +options |
Product Or Component Type | single function relay |
Voltage Drift | +/- 0.2 %/V |
Immunity To Radioelectric Fields | 10 V 0.15...80 MHz)EN/IEC 61000-4-6 level 3 |
Immunity To Voltage Dips | >= 95 % / 1 s EN/IEC 61000-4-11 || 30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11 |
Output Overvoltage Protection | 2 J |
Surge Withstand | 2 kV EN/IEC 61000-4-5 level 3 |
Contacts Type And Composition | 4 C/O |
Local Signalling | for output in operation 1 LED (red) || for power ON 1 LED (yellow) |
Power Consumption In Va | 1.7 VA |
Dielectric Strength | 2 kV 1 mA/1 minute 50 Hz EN/IEC 60601-1 || 2 kV 1 mA/1 minute 50 Hz EN/IEC 61812-1 |
Voltage Range | 0.85...1.15 Us |
Ip Degree Of Protection | IP50 conforming to IEC 60529 |
Line Rated Current | 5 A AC |
Relative Humidity | 95-95 % without condensation IEC 60068-2-6 |
Time Delay Type | power on-delay |
Resistance To Electromagnetic Fields | 10 V/m EN/IEC 61000-4-3 level 3 |
Ambient Air Temperature For Operation | -20-60°C |
Temporary Permissible Current | 10 A < 10 s |
Temperature Drift | 0.05 %/°C |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Repeat Accuracy | +/- 0.5 % |
Minimum Switching Current | 100 mA |
Product Certifications | UL || cUL |
Resistance To Fast Transients | 2 kV EN/IEC 61000-4-4 level 3 |
Ambient Air Temperature For Storage | -40-70°C |
Fixing Mode | plug-in socket) |
Setting Accuracy Of Time Delay | 10 % at full scale 25°C EN/IEC 61812-1 |
Component Name | REXL |
Vibration Resistance | 0.35 mm 10-55 Hz)IEC 60068-2-6 |
Electrical Durability | 100000 cycles 250 V AC resistive |
Reset Time | 250 ms after time delay, on de-energisation || 50 ms during time delay, on de-energisation |
Discrete Output Type | relay |
Time Delay Range | 6...60 s || 1...10 s || 1...10 h || 1...10 min || 6...60 min || 10...100 h || 0.1...1 s |
[Ui] Rated Insulation Voltage | 250 V IEC 255 Group C || 250 V VDE 0010 |
Disturbance Radiated/Conducted | class B EN 55022 (EN 55011 group 1) |
Contacts Material | cadmium free |
Resistance To Electrostatic Discharge | 6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3 |
[Us] Rated Supply Voltage | 24 V AC 50/60 Hz |
Maximum Switching Capacity | 4 x 5 A |
Immunity To Microbreaks | 5 ms |
Mechanical Durability | 10000000 cycles |
Country of Origin (subject to change) | India |
Package Quantity | 1 |
Timer, 250VAC 3A, Rexl +options, SCHNEIDER ELECTRIC, Mfr# REXL4TMB7
$63,15
Free shipping will be applied on orders over $50
Timer,250VAC 3A,Rexl +options
Out of stock
You must be logged in to post a review.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov