Standards | 73/23/EEC || 93/68/EEC || EN 50082-1/2 || 89/336/EEC || EN 50081-1/2 || IEC 61812-1 || IEC 60669-2-3 |
Item | Timer,250VAC,5A,Re48 +options |
Power Consumption In W | 0.5 W 24 V || 1.7 W 240 V |
Protection Against Electric Shocks | 4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1 |
Humidity Drift | +/- 0.05 %/%RH of the maximum setting value IEC 61812-1 |
Minimum Switching Current | 100 mA |
Breaking Capacity | 1250 VA |
Ambient Air Temperature For Operation | -20-50°C |
On-Load Factor | 1 |
Repeat Accuracy | +/- 0.2 % of the maximum setting value IEC 61812-1 |
Minimum Pulse Duration | 20 ms |
Time Delay Range | 5...300 h || 2...120 min || 0.5...30 h || 0.2...12 h || 0.2...12 min || 0.2...12 s || 0.5...30 min || 2...120 h || 2...120 s || 0.02...1.2 s || 0.5...30 s || 5...300 s || 0.05...3 s || 5...300 min |
Maximum Switching Current | 5A |
Voltage Drift | +/- 0.2 %/V of the maximum setting value 48...240 V || +/- 1 %/V of the maximum setting value 24...48 V |
Component Name | RE48 |
Immunity To Voltage Dips | 30 % / 10 ms EN/IEC 61000-4-11 || 60 % / 100 ms EN/IEC 61000-4-11 || 95 % / 5 s EN/IEC 61000-4-11 |
Relative Humidity | 93-93 % without condensation IEC 60068-2-3 |
Dielectric Strength | 1 kV 1 mA/1 minute IEC 61812-1 |
Ip Degree Of Protection | IP40 IEC 60529 housing) || IP50 IEC 60529 front face) |
Product Front Plate Size | 48 x 48 mm |
Voltage Range | 0.85...1.1 Us AC || 0.9...1.1 Us DC |
Control Type | selector switch front panel |
Marking | CE |
Reset Time | 25 ms on de-energisation |
Line Rated Current | 5A |
Output Voltage | 240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15 |
Local Signalling | for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green) |
Mounting Support | panel mounted: system supplied with the product || base mounted: socket |
Setting Accuracy Of Time Delay | +/- 5 % of full scale 25°C IEC 61812-1 |
Housing Material | self-extinguishing |
Temperature Drift | +/- 0.02 %/°C of the maximum setting value IEC 61812-1 |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Surge Withstand | 1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3 |
Electrical Connection | plug-in sub-base 8 |
Mechanical Durability | 30000000 cycles |
Discrete Output Type | relay |
Power Consumption In Va | 1.1 VA 24 V || 4.8 VA 240 V |
Immunity To Radioelectric Fields | 10 V 0.15...80 MHz)EN/IEC 61000-4-6 level 3 |
Contacts Type And Composition | 2 C/O timed contacts, AgNi (cadmium free) |
Product Or Component Type | single function relay |
Time Delay Type | power on-delay |
Resistance To Electromagnetic Fields | 10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3 |
Electrical Durability | 100000 cycles |
Immunity To Microbreaks | 10 ms |
Product Certifications | UL || cULus || C-tick || CSA |
Disturbance Radiated/Conducted | class B 0.15...30 MHz EN 55022 (EN 55011 group 1) |
Resistance To Fast Transients | 2 kV EN/IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV EN/IEC 61000-4-4 level 4 direct) |
Resistance To Electrostatic Discharge | 6 kV in contact EN/IEC 61000-4-2 level 3 || 8 kV in air EN/IEC 61000-4-2 level 3 |
Vibration Resistance | 0.35 mm 10-55 Hz)IEC 60068-2-6 |
Ambient Air Temperature For Storage | -40-70°C |
Pick Up Duration | 55 ms |
Maximum Switching Voltage | 250 V AC/DC |
Country of Origin (subject to change) | India |
Package Quantity | 1 |
Timer, 250VAC, 5A, Re48 +options, SCHNEIDER ELECTRIC, Mfr# RE48ATM12MW
$79,25
Free shipping will be applied on orders over $50
Timer,250VAC,5A,Re48 +options
Out of stock
You must be logged in to post a review.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Reviews