Temp. Range
High Limit 130 Degrees to 240 Degrees F, Low Limit 110 Degrees to 220 Degrees F
Differential
High Limit 10 Degrees F Fixed, Low Limit 10 Degrees to 25 Degrees F Adj.
Full Load Amps @ 120VAC
7.4 A
Type
Triple Aquastat Relay with High Limit
Burner Control Circuit
24V
Includes
Diaphragm Powerhead, Extra Terminals, Micro Switch Assembly, Range Stops, Transformer, Heat-Conductive Compound
Locked Rotor Amps @ 120V
44.4 A
Requires
Tube of Heat Conductive Compound and Range Stops
Burner Control Circuit @ 24V (A)
1.25 A
Agency Compliance
UL u0026 CSA
Locked Rotor Amps @ 240V
22.7 A
Full Load Amps @ 240VAC
3.7 A
Product Type
Immersion Controller
Mounting Orientation
Vertical
Reset Type
Automatic Reset
Full Load Current @ 120V AC
7.4 A
Maximum Control Temperature
240 Degrees F
Locked Rotor Current @ 120V
44.4 A
Differential Temperature
10 Degrees F Fixed (High Limit), 10 Degrees F to 25 Degrees F Adjustable (Low Limit)
Full Load Current @ 240V AC
3.7 A
Multizone Control Compatible
Yes
Capillary Tube Length
3 3/8 in
Burner Circuit Voltage Type
Low Voltage
Number of Zone Control Valves Supported
1
Standards
CSA Certified, UL Listed
Auto/Manual Switch Included
Yes
Number of Zone Control Relays Supported
1
Minimum Control Temperature
130 Degrees F
Locked Rotor Current @ 240V
22.2 A
Country of Origin (subject to change)
United States