Item
Rectangular Ultrasonic Sensor
Electrical Connection
4 Pin M12 Male Connector
Power Required
12 to 24V DC
Operating Frequency
300 kHz
Operating Temp. Range
-22 Degrees to 152 Degrees F
Description/Special Features
Dual Mount Body Style
Length (Straight Wireway)
2.35 in
Type Of Sensing Window
adjustable
Ambient Air Temperature For Operation
-30-70°C
Vibration Resistance
+/-1 mm 10-55 Hz)IEC 60068-2-6
Minimum Size Of Detected Object
cylinder diameter 2.5 mm - up to 200 mm sensing distance
Maximum Switching Current
100 mA reverse polarity protection
Resistance To Electromagnetic Fields
10 V/m level 3 IEC 61000-4-3
Transmission Frequency
300 kHz
Ip Degree Of Protection
IP67
[Sn] Nominal Sensing Distance
508-508 mm
Discrete Output Function
1 NO
Front Material
glass epoxy
Nema Degree Of Protection
NEMA 4X indoor use only)
Sensor Type
ultrasonic sensor
Type Of Output Signal
discrete
Status Led
output not active 1 LED green)
[Sd] Sensing Range
50.8-508 mm
Resistance To Fast Transients
1 kV level 3 IEC 61000-4-4
[Us] Rated Supply Voltage
12...24 V DC overload and short-circuit protection
Ambient Air Temperature For Storage
-40-85°C
Resistance To Electrostatic Discharge
8 kV level 4 IEC 61000-4-2
Relative Humidity
100-100 % without condensation
Supply Voltage Limits
10-28 V DC
[Sa] Assured Operating Distance
50.8-508 mm remote teach push-button
Sensor Design
flat form + cylindrical M18
Shock Resistance
30 gn in all 3 axes 11 ms IEC 60068-2-27
Country of Origin (subject to change)
United States