Compatible Material
Concrete
ICC Approved for Cracked Concrete
Yes
Minimum Installation Depth
71 mm
Maximum Material Thickness
45 mm
Ultimate Shear Strength (4,000 psi Concrete)
12,510 lb
Ultimate Tension Strength (4,000 psi Concrete)
7,717 lb
Allowable Shear in 6500 PSI Uncracked Concrete (Lbs.)
3778
Allowable Tension in 6500 PSI Uncracked Concrete (Lbs.)
4187
Embedment In Concrete
71 mm
Allowable Shear in 2500 PSI Cracked Concrete (Lbs.)
3778
Allowable Tension in 2500 PSI Uncracked Concrete (Lbs.)
2604
Allowable Tension in 2500 PSI Cracked Concrete (Lbs.)
1549
Allowable Tension in 6500 PSI Cracked Concrete (Lbs.)
2490
Allowable Shear in 2500 PSI Uncracked Concrete (Lbs.)
3778
Allowable Shear in 6500 PSI Cracked Concrete (Lbs.)
3778
Thread Length
Not Applicable
ICC Approved for Un-Cracked Concrete
Yes
Industry Standards
ACI 355.2/ETA-02-0030
Wedge Anchor Type
Seismic Wedge Anchor
Eyelet Hole Size
Not Applicable
Maximum Installation Torque
37 ft-lb
Minimum Ultimate Tension Strength
3,765 lb
Washer Outside Diameter
24 mm
Manufacturer Location
Made in USA
Minimum Ultimate Shear Strength
5,620 lb
System of Measurement
Metric
Minimum Installation Torque
37 ft-lb
Minimum Material Thickness
152 13/32 mm
Material Quality Standards
ACI 318 Category 1
Material Grade/Class
Class 8.8
Maximum Ultimate Tension Strength
21,444 lb
Maximum Ultimate Shear Strength
44,623 lb
Country of Origin (subject to change)
Germany