Compatible Material
Concrete
ICC Approved for Cracked Concrete
Yes
Minimum Installation Depth
100 mm
Maximum Material Thickness
50 mm
Ultimate Shear Strength (4,000 psi Concrete)
38,920 lb
Ultimate Tension Strength (4,000 psi Concrete)
14,057 lb
Embedment In Concrete
100 mm
Allowable Shear in 6500 PSI Cracked Concrete (Lbs.)
9519
Allowable Shear in 2500 PSI Cracked Concrete (Lbs.)
6640
Allowable Tension in 2500 PSI Cracked Concrete (Lbs.)
3083
Allowable Tension in 6500 PSI Cracked Concrete (Lbs.)
4958
Allowable Shear in 2500 PSI Uncracked Concrete (Lbs.)
6640
Allowable Tension in 6500 PSI Uncracked Concrete (Lbs.)
6999
Allowable Tension in 2500 PSI Uncracked Concrete (Lbs.)
4352
Allowable Shear in 6500 PSI Uncracked Concrete (Lbs.)
9519
ICC Approved for Un-Cracked Concrete
Yes
Thread Length
Not Applicable
Industry Standards
ACI 355.2/ETA-02-0030
Wedge Anchor Type
Seismic Wedge Anchor
Maximum Ultimate Tension Strength
21,444 lb
Maximum Installation Torque
118 ft-lb
Minimum Ultimate Tension Strength
3,765 lb
Maximum Ultimate Shear Strength
44,623 lb
Washer Outside Diameter
39 mm
Material Quality Standards
ACI 318 Category 1
System of Measurement
Metric
Minimum Material Thickness
203 13/64 mm
Minimum Ultimate Shear Strength
5,620 lb
Material Grade/Class
Class 8.8
Minimum Installation Torque
118 ft-lb
Eyelet Hole Size
Not Applicable
Manufacturer Location
Made in USA
Country of Origin (subject to change)
Germany