Standards | EN/IEC 61800-5-1 || EN/ISO 13849-1 || EN/IEC 61508 || IEC 62061 |
Depth | 114.5 mm |
Height | 99 mm |
Item | With Wit Safety Ro Out Expansion Diag. 4 |
Width | 22.5 mm |
Mechanical Durability | 20000000 cycles |
Maximum Power Dissipation In W | 3 W |
Vibration Resistance | +/-0.35 mm 10-55 Hz)EN/IEC 61496-1 |
Cable Cross Section | 0.2-1.5 mm? - AWG 24...AWG 16 flexible without cable end || 0.2-2.5 mm? - AWG 24...AWG 14 flexible without cable end || 0.25-1 mm? - AWG 23...AWG 18 flexible with cable end, without bezel || 0.25-2.5 mm? - AWG 23...AWG 14 flexible with cable end, with bezel || 0.25-2.5 mm? - AWG 23...AWG 14 flexible with cable end, without bezel || 0.5-1.5 mm? - AWG 20...AWG 16 flexible with cable end, with double bezel || 0.2-1 mm? - AWG 24...AWG 18 solid without cable end || 0.2-2.5 mm? - AWG 24...AWG 14 solid without cable end |
Quality Labels | CE |
Mounting Support | omega 35 mm DIN rail EN 50022 |
Product Or Component Type | safe relay output module |
Electrical Durability | 20000000 cycles |
Minimum Switching Current | 20 mA |
[Us] Rated Supply Voltage | 24 V - 20...20 % DC |
Ip Degree Of Protection | IP20 |
Connections - Terminals | 2 captive screw clamp terminals, removable terminal block || 1 captive screw clamp terminals, removable terminal block |
Electromagnetic Compatibility | electrostatic discharge immunity test 6 kV on contact) EN/IEC 61000-4-2 || electrostatic discharge immunity test 20 kV on air) EN/IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80...1000 MHz) EN/IEC 61000-4-3 || susceptibility to electromagnetic fields 30 V/m 1.4 GHz...2 GHz) EN/IEC 61000-4-3 |
Device Short Name | XPSMCM |
Number Of Terminal Blocks | 6 |
Switching Voltage | 10 V DC |
Pollution Degree | 2 |
Safety Level | can reach category 4 EN/ISO 13849-1 || can reach PL = e EN/ISO 13849-1 || can reach SIL 3 EN/IEC 61508 || SILCL 3 IEC 62061 |
Product Certifications | cULus || TUV || RCM |
Output Type | relay, 4 NO, volt-free |
Switching Time | 12 ms |
Overvoltage Category | II |
Maximum Switching Current | 6A |
Electrical Connection | screw terminal |
Integrated Connection Type | backplane expansion bus |
Discrete Output Number | 8-8 solid state 125 mA diagnostics) |
Ambient Air Temperature For Operation | -10-55°C |
Number Of Outputs | 4 relay |
Maximum Switching Voltage | 400 V AC || 250 V DC |
Associated Fuse Rating | 3.5 A, slow-blow |
Insulation | 250 V AC between power supply and housing EN/IEC 61800-5-1 |
Function Of Module | monitoring safety actuators relay output |
Relative Humidity | 10-95 % |
[Uimp] Rated Impulse Withstand Voltage | 4 kV EN/IEC 61800-5-1 |
Ambient Air Temperature For Storage | -20-85°C |
Shock Resistance | 10 gn 16 ms 1000 shocks on each axis)EN/IEC 61496-1 |
Local Signalling | 1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 2 LEDs orange ADDR node address || 4 LEDs green/red RELAY K1...K4 relay contact || 4 LEDs yellow RST requires reset || 8 LEDs yellow STATUS diagnostics output |
Country of Origin (subject to change) | Italy |
Package Quantity | 1 |
With Wit Safety Ro Out Expansion Diag. 4, SCHNEIDER ELECTRIC, Mfr# XPSMCMRO0004DA
$565,99
Free shipping will be applied on orders over $50
With Wit Safety Ro Out Expansion Diag. 4
9999 in stock
Must order in multiples of 1
Subtotal:
$565.99
You must be logged in to post a review.
Reviews
There are no reviews yet.