Monitor Relay, Contact Form DPDT, Contact Rating (AC) 8 A @ 250V, Contact Rating (DC) 0.01 A @ 5V, Current Rating 8 A, Input Voltage 24 to 240V AC/DC, Monitored Parameters Overcurrent, Undercurrent, Mounting Style DIN Rail, Number of Pins 9, Trip Point Adjustable 0.01 to 1.00 A, Electrical Connection Terminal Strip, Body Depth 3.13 in, Body Height 3.54 in, Body Width 0.89 in

9999 in stock

Must order in multiples of 1
Subtotal:
$110.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: RM22JA31MR
Availability: Ships in 5 days
SKU: GRG7124142 Category:
Item - RelayCurrent Sensing Relay
AC Contact Rating - Relay8 A @ 250 V
DC Contact Rating - Relay0.01 A @ 5 V
Contact Form - RelayDPDT
Mounting - RelayDIN Rail
StandardsCCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed
Contact FormDPDT
Body Width - Relay0.89 in
Overall Height - Relay3.65 in
Body Height - Relay3.54 in
ItemMonitor Relay
Body Depth - Relay3.15 in
Response Time<= 500 ms
Trip PointAdjustable 0.01 to 1.00 A
Trip Delay0.1 to 30 sec
Electrical ConnectionTerminal Strip
Type of OutputRelay
Sensing Amp Range0.01 to 1.00 A
Input or Control Voltage20 to 264 V AC/DC
Core Type - RelaySolid
Power Consumption3.5 VA
Input Voltage24 to 240V AC/DC
Mechanical Operating Durability10,000,000
Weight0.24 lb
Maximum Operating Temperature158 Degrees F
Maximum Switching Capacity2,000 VA
Number of Pins9
Overall Depth3.13 in
Body Height3.54 in
Current Rating8 A
IP RatingIP20, IP40, IP50
Body Width0.89 in
Contact Rating (DC)0.01 A @ 5V
Contact Rating (AC)8 A @ 250V
Minimum Operating Temperature-40 Degrees F
Monitored ParametersOvercurrent, Undercurrent
Body Depth3.13 in
Mounting StyleDIN Rail
Minimum Switching Current10 mA
Maximum Switching Voltage250V AC
Control Circuit Voltage Limits15 % + 10 % Un
Ambient Air Temperature For Operation-20-50°C 60 Hz || -20-60°C 50 Hz
Dielectric Test Voltage2.5 kV AC 50 Hz, 1 min IEC 60255-27
Relay Monitored Parametersovercurrent or undercurrent detection || overcurrent or undercurrent in window mode
Relay Typecurrent control relay
Time Delay Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Maximum Power Consumption In Va3.5 VA
Tightening Torque0.6-1 N.m IEC 60947-1
Maximum Power Consumption In W1.5 W DC
Run-Up Delay At Power-Up0.3 s
Ambient Air Temperature For Storage-40-70°C
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Threshold Setting10...100 %
Relay NameRM22JA
Reset Time1500 ms at maximum voltage
Connections - Terminalsscrew terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm? AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 14) flexible with cable end
Setting Accuracy Of The Switching Threshold+/- 10 % of the full scale
Local Signallingfor relay ON LED (yellow) || for power ON LED (green)
Repeat Accuracy+/- 0.5 % input and measurement circuit || +/- 0.2 % time delay
Pollution Degree3 IEC 60664-1 || 3 UL 508
Overvoltage CategoryIII IEC 60664-1 || III UL 508
Electrical Durability100000 cycles
Measurement Range4...40 mA E1-M terminals || 20...200 mA E2-M terminals || 100...1000 mA E3-M terminals || 4 mA...1 A current AC/DC 50/60 Hz
Output Contacts2 C/O
Contacts Materialcadmium free
Setting Accuracy Of Time Delay0.916666666666667
Measurement Error< 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
Contacts Type And Composition2 C/O
Product CertificationsCSA || CE || EAC || CCC || GL || RCM || UL
Maximum Switching Current8 A AC
Nominal Output Current8A
Internal Input Resistance0.5 Ohm || 2.5 Ohm || 0.1 Ohm
Utilisation CategoryAC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Width22.5 mm
Electromagnetic Compatibilityimmunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22
Maximum Measuring Cycle100 ms measurement cycle as true rms value
Shock Resistance15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
Mechanical Durability10000000 cycles
Switching Capacity In Va2000 VA
Insulation Resistance> 100 MOhm 500 V DC IEC 60255-27
Supply Voltage Limits20.4-264 V AC/DC
Vibration Resistance0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
Immunity To Microbreaks50 ms
Time Delay Typeadjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Insulationbetween supply and measurement
Housing Materialself-extinguishing plastic
Resistance Across Terminals2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals
Switching Threshold Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Relative Humidity93-97 % 25-55°C IEC 60068-2-30
Hysteresis5-50 % adjustable threshold setting || 3-3 % fixed full scale for window mode
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
Product Or Component Typecurrent control relay
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#Monitor Relay
#8 A
#24-240VAC/DC
#9 Pins
#SCHNEIDER ELECTRIC
#Mfr RM22JA31MR
#SCHNEIDER ELECTRIC
#GRG7124142
#mfr:RM22JA31MR
#part number:RM22JA31MR
#pn:RM22JA31MR
#part code:RM22JA31MR
#item number:RM22JA31MR
#product code:RM22JA31MR
#manufacturer number:RM22JA31MR
#manufacturers part number:RM22JA31MR
#mfn:RM22JA31MR

Reviews

There are no reviews yet.

Add a review
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
You have not viewed any product yet!