Item | Timer24-240VAC/VDC,In8A,Dpdt Outde-en |
Standards | IEC 61812-1 || UL 508 |
Width | 22.5 mm |
Product Certifications | EAC || UL || RCM || GL || CCC || CSA || CE |
Housing Material | self-extinguishing |
Connections - Terminals | screw terminals, 1 x 0.5...1 x 3.3 mm? AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end |
Electromagnetic Compatibility | fast transients immunity test 1 kV capacitive connecting clip)level 3 IEC 61000-4-4 || surge immunity test 1 kV differential mode)level 3 IEC 61000-4-5 || surge immunity test 2 kV common mode)level 3 IEC 61000-4-5 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/m 80 MHz...1 GHz)level 3 IEC 61000-4-3 || conducted RF disturbances 10 V 0.15...80 MHz)level 3 IEC 61000-4-6 || fast transient bursts 2 kV direct contact)level 3 IEC 61000-4-4 || immunity to microbreaks and voltage drops 30 % 500 ms) IEC 61000-4-11 || immunity to microbreaks and voltage drops 100 % 20 ms) IEC 61000-4-11 |
Maximum Switching Voltage | 250 V AC |
Reset Time | 100 ms on de-energisation |
Immunity To Microbreaks | 10 ms |
Time Delay Range | 10...100 s || 0.05...1 s || 30...300 s || 3...30 s || 1...10 min || 1...10 s || 0.3...3 s |
Relative Humidity | 95-95 % 25-55°C |
Contacts Type And Composition | 2 C/O timed contact, cadmium free |
Switching Capacity In Va | 1250 VA |
Ambient Air Temperature For Storage | -40-70°C |
Device Short Name | RE22 |
Input Voltage | <= 2.4 V |
Ambient Air Temperature For Operation | -20-60°C |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Maximum Delay Response | 200 ms |
Dielectric Strength | 2.5 kV 1 mA/1 minute 50 Hz between relay output and power supply basic insulation IEC 61812-1 |
Repeat Accuracy | +/- 0.5 % IEC 61812-1 |
Product Or Component Type | single function relay |
Nominal Output Current | 5A |
Overvoltage Category | III IEC 60664-1 |
Insulation Resistance | 100 MOhm 500 V DC IEC 60664-1 |
[Uimp] Rated Impulse Withstand Voltage | 5 kV 1.2-50µs IEC 60664-1 |
Power Consumption In W | 2 W 240 V DC |
Setting Accuracy Of Time Delay | +/- 10 % of full scale 25°C IEC 61812-1 |
Status Led | Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED steady)power ON |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Vibration Resistance | 20 m/s? 10-150 Hz)IEC 60068-2-6 |
Maximum Switching Current | 5A |
Voltage Range | 0.85...1.1 Us |
Pollution Degree | 3 IEC 60664-1 |
Creepage Distance | 4 kV/3 IEC 60664-1 |
Minimum Switching Current | 10 mA 5 V DC |
Supply Frequency | 50...60 Hz +/- 5 % |
Mechanical Durability | 10000000 cycles |
Discrete Output Type | relay |
[Us] Rated Supply Voltage | 24...240 V AC/DC 50/60 Hz |
Voltage Drift | +/- 0.2 %/V |
Mounting Position | any position |
Electrical Durability | 100000 cycles, 2 A at 24 V, DC-1 || 100000 cycles, 5 A at 250 V, AC-1 |
Time Delay Type | delay on de-energization |
Power Consumption In Va | 3-3 VA 240 V AC |
Ip Degree Of Protection | housing IP40 IEC 60529 || terminals IP20 IEC 60529 || front panel IP50 IEC 60529 |
Temperature Drift | +/- 0.05 %/°C |
Control Type | rotary knob || potentiometer external |
Shock Resistance | 15 gn not operating 11 ms IEC 60068-2-27 || 5 gn in operation 11 ms IEC 60068-2-27 |
Country of Origin (subject to change) | India |
Package Quantity | 1 |
Timer24-240VAC/VDC, In8A, Dpdt Outde-en, SCHNEIDER ELECTRIC, Mfr# RE22R2KMR
$107,99
Free shipping will be applied on orders over $50
Timer24-240VAC/VDC,In8A,Dpdt Outde-en
0 in stock
Must order in multiples of 1
Subtotal:
$107.99
You must be logged in to post a review.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Reviews
There are no reviews yet.