Item | Blower |
Type | Direct Drive Forward Curve, Hazardous Location, |
Wheel Dia. (In.) | 6 in |
Voltage | 115/230 |
Motor HP | 1/4 hp |
Motor Type | Hazardous Location, Single Phase |
Hz | 60 Hz |
Full Load Amps | 4.8/2.4 |
CFM @ 0.500-In. SP | 70 |
CFM @ 2.000-In. SP | 90 |
Phase | 1 |
Blower RPM | 3,450 RPM |
Max. Inlet Temp. (Deg. F) | 140 Degrees F |
Motor Enclosure | Explosion Proof |
CFM @ 0.750-In. SP | 75 |
dBA @ 5 Feet | 74 dBA |
CFM @ 1.000-In. SP | 90 |
Housing Material | Plastic |
Wheel Material | Plastic |
Inlet Dia. (In.) | 2.95 in |
Motor Frame | 71 |
Shaft Dia. (In.) | 14 mm |
Housing Finish | Polypropylene |
Motor RPM | 3,450 RPM |
Agency Compliance | AMCA and CSA certified, UL Listed |
Rotation | CCW |
Material | Plastic Wheel & Plastic Housing |
Bearing Type | Sealed, Permanently Lubricated Ball |
Height (In.) | 18.97 in |
Depth (In.) | 13.75 in |
Wheel Width (In.) | 1.88 in |
Includes | Motor Mounting Base |
Wheel Type | Forward-Curved |
Width (In.) | 8.64 in |
Max. Ambient Temp. (F) | -13 Degrees F |
CFM @ 1.250-In. SP | 90 |
Outlet Dia. (In.) | 2.95 in |
CFM @ 1.500-In. SP | 100 |
Mounting Orientation | Multiposition |
Hazardous Location Application | Yes |
Airflow @ 0.500 in SP | 70 cfm |
Flange Size | Not Applicable |
Includes Motor | Yes |
Number of Discharge Positions | 2 |
Flange Type_broad | Outlet |
Outlet Shape | Round |
Nameplate Voltage | 115/230V AC |
Airflow @ Static Pressures | 90 cfm @ 1.000 in SP / 100 cfm @ 1.500 in SP |
Number of Inlets | 1 |
Motor Enclosure Design_Table | Totally Enclosed Motor |
Frequency | 60 Hz |
Shaft Diameter | 14 mm |
Includes Drive Package | Yes |
Thermal Overload Protection | Yes |
Mount Type | Motor Mount |
Overall Height | 18 15/16 in |
Outlet Width | Not Applicable |
Discharge Position | Bottom Horizontal, Down Blast, Top Horizontal, Up Blast |
Housing Width | 8 5/8 in |
Airflow @ 1.000 in SP | 90 cfm |
Minimum Fan Speed | 3,450 RPM |
Overall Width | 8 5/8 in |
Inlet Diameter | 2 15/16 in |
Outlet Diameter | 2 15/16 in |
Nominal Voltage | 115/230V AC |
Airflow @ 1.250 in SP | 90 cfm |
Maximum Static Pressure | 2 1/2 in wc |
Motor Speed | 3,450 RPM |
Airflow @ 1.500 in SP Range | 0 to 999 cfm |
Maximum Inlet Air Temperature | 140 Degrees F |
Outlet Size | 2 7/8 in diameter |
Maximum Ambient Temperature | -13 Degrees F |
Spark Resistant Construction Type | A |
Drive Type | Direct Drive |
Sound Level | 74 dBA @ 5 ft |
Airflow @ 2.000 in SP | 90 cfm |
Current | 4.8/2.4 A |
Inlet Type | Single-Inlet |
Minimum Ambient Temperature | -40 Degrees C |
For Air Type | Contaminated, Damp, Dirty and Dusty, Emergency Smoke Control, Clean Air, High Temperature, Spark Resistant |
Standards | AMCA Certified, CSA Certified, UL Listed |
Overall Depth | 13 3/4 in |
Wheel Diameter | 6 in |
Motor Horsepower | 1/4 hp |
Assembly | Assembled |
Includes Mounting Hardware | Yes |
Maximum Fan Speed | 3,450 RPM |
Airflow @ 1.500 in SP | 100 cfm |
Flange Type | Non-Flanged |
Motor Frame Designation | 71 |
Airflow @ 0.750 in SP | 75 cfm |
For Fan Speed (Dependent on Motor) | 3,450 RPM to 3,450 RPM |
Housing Height | 18 15/16 in |
Outlet Shape_broad | Round |
Wheel Dimensions | 6 in Dia. x 1 7/8 in W |
Airflow @ 0.500 in SP Range | 0 to 999 cfm |
Wheel Width | 1 7/8 in |
Outlet Height | Not Applicable |
Country of Origin (subject to change) | United States |
Package Quantity | 1 |
Blower, Forward Curve, 6 in, PLASTEC, Mfr# S10XS2P016
$4168,99
Free shipping will be applied on orders over $50
Blower, Wheel Type Forward-Curved, Drive Type Direct Drive, Includes Drive Package Yes, Assembly Assembled, Wheel Diameter 6 in, Airflow @ 0.500 in SP 70 cfm, Airflow @ 0.750 in SP 75 cfm, Airflow @ 1.000 in SP 90 cfm, Airflow @ 1.250 in SP 90 cfm, Airflow @ 1.500 in SP 100 cfm, Airflow @ 2.000 in SP 90 cfm
9999 in stock
Must order in multiples of 1
Subtotal:
$4168.99
You must be logged in to post a review.
Reviews
There are no reviews yet.