Drywell, Temperature Calibrator, FLUKE, Mfr# 9190A-E-P-156

$24974,00
Free shipping will be applied on orders over $50

Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D

0 in stock

Must order in multiples of 1
Subtotal:
$24974
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9190A-E-P-156
Availability: Ships in 10 days
SKU: GRG8249193 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Accuracy+/-0.2 Degrees C Full Range
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Loop Supply Voltage24V DC
RTD Type4 Wire, 3 Wire, 2 Wire
RTD Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Calibration Certificateyes
InterfaceRS-232, USB Cable
Includes6 ft Main Power Cord, 9190 Insert E, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
DisplayLCD
Max. Loop Current4 to 20mA
Agency ComplianceEU Directives, CSA, Australian EMC Requirements
Power SourcePlug-In
StandardsIEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
Overall Height18.81 in
Calibrator TypeField Metrology Well
Display Temperature Accuracy+/-0.2 Degrees C
For RTD Type2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
Well Diameter1.19 in
Probe Connection Types(1) 4-Terminal RTD Input, (1) Miniature Connectors (ASTM E1684)
Typical Cooling Time80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C)
Well Size1 3/16 in Dia x 6 5/16 D Well
Thermocouple Temperature Range F-139 Degrees to 284 Degrees F
Current mA Characteristics0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
Typical Uniformity+/-0.05 Degrees C
Calibrator Weight35 lb
Stabilization Time15 min
Typical Heating Time40 min (-95 Degrees to 140 Degrees C)
For Stem Diameter3 mm, 4 mm, 6 mm, 8 mm, 10, mm, 1/4 in
Overall Dimensions18 13/16 in H x 8 in W x 14 29/32 in D
Resistance Sensing Current Characteristics0.02% at 0.002 mA, Cal 4-22 mA, Spec 4-24 mA
Sensor TypeRTD, Thermocouple
Thermocouple Temperature Range C-95 Degrees to 140 Degrees C
Power Source Details100 to 115V, 200 to 230V
Stability+/-0.015 Degrees C
Calibrator Accuracy+/-0.2 Degrees C
Overall Depth14.91 in
With Process ConnectionsYes
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Overall Width8 in
Well Depth6.31 in
Brand and SeriesFluke 9190A
Temperature Range-139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
ApplicationBlood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
RTD Temperature Range C-95 Degrees to 140 Degrees C
RTD Temperature Range F-139 Degrees to 284 Degrees F
Reference Input Temperature Characteristics+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
Display Resolution0.01 Degrees
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Single Well/Dual WellSingle Well
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Number of Set PointsVariable
Set Point StyleAdjustable
Temperature Accuracy+/-0.2 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature Calibrator
#FLUKE
#Mfr 9190A-E-P-156
#FLUKE
#GRG8249193
#mfr:9190A-E-P-156
#part number:9190A-E-P-156
#pn:9190A-E-P-156
#part code:9190A-E-P-156
#item number:9190A-E-P-156
#product code:9190A-E-P-156
#manufacturer number:9190A-E-P-156
#manufacturers part number:9190A-E-P-156
#mfn:9190A-E-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!