Drywell, Temperature Calibrator, FLUKE, Mfr# 9190A-D-P-156

$24974,00
Free shipping will be applied on orders over $50

Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D

9999 in stock

Must order in multiples of 1
Subtotal:
$24974
Final shipping and tax calculated in checkout
Brand Name: FLUKE
Mfr #: 9190A-D-P-156
Availability: Ships in 10 days
SKU: GRG7863965 Category:
Promotion RestrictionNot eligible for promotion
ItemDrywell
Thermocouple TypeC, E, J, K, L, M, N, R, S, T, U
Accuracy+/-0.2 Degrees C Full Range
Loop Supply Voltage24V DC
RTD Type4 Wire, 3 Wire, 2 Wire
RTD Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Max. Loop Current4 to 20mA
Includes6 ft Main Power Cord, 9190 Insert D, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
Agency ComplianceEU Directives, CSA, Australian EMC Requirements
Calibration Certificateyes
InterfaceRS-232, USB Cable
DisplayLCD
StandardsIEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
Power SourcePlug-In
Display Temperature Accuracy+/-0.2 Degrees C
Calibrator TypeField Metrology Well
Well Depth6.31 in
Thermocouple Temperature Range C-95 Degrees to 140 Degrees C
Typical Cooling Time80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C), 60 min (140 Degrees to 23 Degrees C)
Current mA Characteristics0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
RTD Temperature Range C-95 Degrees to 140 Degrees C
RTD Temperature Range F-139 Degrees to 284 Degrees F
Overall Width8 in
Stability+/-0.015 Degrees C
Reference Input Temperature Characteristics+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Stabilization Time15 min
Typical Heating Time40 min (-95 Degrees to 140 Degrees C)
Power Source Details100 to 115V, 200 to 230V
Well Size1 3/16 in Dia x 6 5/16 D Well
Sensor TypeRTD, Thermocouple
For Thermocouple TypeType C, Type E, Type J, Type K, Type L, Type M, Type N, Type R, Type S, Type T, Type U
Brand and SeriesFluke 9190A
Calibrator Weight35 lb
For RTD Type2-Wire, 3-Wire, 4-Wire, Ni-120, PT-100 (385), PT-100 (3926), PT-100 (JIS)
For Stem Diameter(2) 3 mm, (2) 4 mm, (2), 6 mm
Reference Junction Temperature Characteristics+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Reference Input Resistance Characteristics+/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Overall Height18.81 in
Well Diameter1.19 in
Probe Connection Types(1) 4-Terminal RTD Input, (1) Miniature Connectors (ASTM E1684)
Thermocouple Temperature Range F-139 Degrees to 284 Degrees F
Resistance Sensing Current Characteristics0.02% at 0.002 mA, Cal 4-22 mA, Spec 4-24 mA
ApplicationBlood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
Thermocouple mV Characteristics0.025% + 0.01 mV at -10 to 75 mV
With Process ConnectionsYes
Display Resolution0.01 Degrees
Thermocouple Temperature Accuracy CharacteristicsType C: +/-1.00 Degrees C at 140 Degrees C, Type E: +/-0.60 Degrees C at 140 Degrees C, Type J: +/-0.70 Degrees C at 140 Degrees C, Type K: +/-0.75 Degrees C at 140 Degrees C, Type L: +/-0.65 Degrees C at 140 Degrees C, Type M: +/-0.65 Degrees C at 140 Degrees C, Type N: +/-0.75 Degrees C at 140 Degrees C, Type R: +/-1.60 Degrees C at 140 Degrees C, Type S: +/-1.60 Degrees C at 140 Degrees C, Type T: +/-0.60 Degrees C at 140 Degrees C, Type U: +/-0.70 Degrees C at 140 Degrees C
Calibrator Accuracy+/-0.2 Degrees C
Typical Uniformity+/-0.05 Degrees C
Overall Dimensions18 13/16 in H x 8 in W x 14 29/32 in D
Overall Depth14.91 in
Temperature Range-139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C
4-Wire Device Resistance CharacteristicsRange: 0 to 400 ohms/Accuracy: +/-0.0025 ohms (0 to 42 ohms), +/-60 ppm of Reading (42 to 400 ohms)
Number of Set PointsVariable
Single Well/Dual WellSingle Well
Set Point StyleAdjustable
Temperature Accuracy+/-0.2 Degrees C
Country of Origin (subject to change)United States
Package Quantity1
TAGS:
#Drywell
#Temperature Calibrator
#FLUKE
#Mfr 9190A-D-P-156
#FLUKE
#GRG7863965
#mfr:9190A-D-P-156
#part number:9190A-D-P-156
#pn:9190A-D-P-156
#part code:9190A-D-P-156
#item number:9190A-D-P-156
#product code:9190A-D-P-156
#manufacturer number:9190A-D-P-156
#manufacturers part number:9190A-D-P-156
#mfn:9190A-D-P-156

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!